Resumen del contenido incluido en la página 1
Instructions Manual
Manual de instrucciones
Manual de Instruções
KIV90XT
Resumen del contenido incluido en la página 2
EN INDEX RECOMMENDATIONS AND SUGGESTIONS ..................................................................................................................... 3 CHARACTERISTICS ............................................................................................................................................................. 4 INSTALLATION.....................................................................................................................................................
Resumen del contenido incluido en la página 3
RECOMMENDATIONS AND SUGGESTIONS The Instructions for Use apply to several versions of this appliance. Accord- ingly, you may find descriptions of individual features that do not apply to your specific appliance. INSTALLATION � The manufacturer will not be held liable for any damages resulting from in- correct or improper installation. � The minimum safety distance between the cooker top and the extractor hood is 650 mm (some models can be installed at a lower height, please re- fer to the p
Resumen del contenido incluido en la página 4
CHARACTERISTICS Dimensions
4 EN 4
Resumen del contenido incluido en la página 5
Components Ref. Q.ty Product Components 1 1 Hood Canopy complete with: Controls, Lights, Filters 2 1 Telescopic chimney made up of: 2.1 1 Upper chimney 2.2 1 Lower chimney 7.1 1 Telescopic frame complete with Suction fan, made up
of: 7.1a 1 Upper frame 7.1b 1 Lower frame 8a 1 Rh Air Outlet Directional Grille 8b 1 Lh Air Outlet Directional Grille 9 1 Reduction flange ø 150-120 mm 10 1 Dumper
14.1 1 Air Outlet Connector Extensi
Resumen del contenido incluido en la página 6
INSTALLATION Drilling the Ceiling/shelf and fixing the frame DRILLING THE CEILING/SHELF • Use a plumb line to mark the centre of the hob on the ceiling/support shelf. � Place the drilling template 21 provided on the ceiling/support shelf, making sure that the template is in the correct position by lining up the axes of the template with those of the hob. � Mark the centres of the holes in the template. � Drill the holes at the points marked: � For concrete ceilings, drill for plugs appro
Resumen del contenido incluido en la página 7
Fixing the frame � Loosen the two screws fastening the lower chimney and re- move this from the lower frame. � Loosen the two screws fastening the upper chimney and re- move this from the upper frame. If you wish to adjust the height of the frame, proceed as follows: � Unfasten the metric screws joining the two columns, located at the sides of the frame. � Adjust the frame to the height required, then refit all the screws removed as above. � Insert the upper chimney stack from above,
Resumen del contenido incluido en la página 8
RECIRCULATION VERSION AIR OUTLET � Assemble the two halves of the hood body extension piece 14
(if necessary). � Push fit the assembled hood body extension piece 14 onto the air outlet (if necessary). � Push fit connection 15 onto the hood body extension piece 14 or directly onto the hood body. � Insert the connection extension pieces laterally 14.1 in connec- tion 15. Should the central reinforcing piece of the frame somehow inter- fere the chimney air outlet grille, it
Resumen del contenido incluido en la página 9
ELECTRICAL CONNECTION � Connect the Hood to the Mains power sup- ply, inserting a two-pole Switch with a con- 1 tact aperture of at least 3 mm. � Remove the Metal grease filters (see par. on “Maintenance”) and make sure that the 2 power supply Cable is properly inserted in the Suction fan socket. � Take the wires indicated in fig.1 and pass them through the slot formed on the galva- nized diffuser support, as shown in fig.2. � Position the finishing plug 27 over the 4 3 housing in the di
Resumen del contenido incluido en la página 10
USE Control panel Button Function Led L Press briefly to turn the lighting system on and off. - Press and hold for approx. 2 seconds to turn the lighting system on and off at reduced intensity. T1 Turn the suction motor on and off at speed one. On. If the filter saturation alarm is on, this resets it. T2 Turn the suction motor on at speed two. On. If the filter saturation alarm is on, this resets it. T3 Press once to turn the suction motor on and off at speed thr
Resumen del contenido incluido en la página 11
MAINTENANCE Metal grease filters These can also be washed in the dishwasher, and need to be cleaned when all the command LEDs light up in a continuous manner or at least once every 2 months use, or more frequently if use is particularly intensive. Resetting the alarm signal � Press any of the buttons except the Light button. Cleaning the Filters � Remove the Filters one at a time, pushing them towards the back of the unit and at the same time pulling downward. � Wash the Filters withou
Resumen del contenido incluido en la página 12
Activated Charcoal Filter (Recirculation Version) � This cannot be washed or regenerated, and must be changed when all the command LEDs start to flash, or at least once every 4 months. Activating the alarm signal � In Recirculation Version Hoods, the Filter Saturation Alarm must be activated on installation or at a later date. � Press and hold the Delay button (T4) on the keypad for 5 seconds and the following will be dis- played: � Leds (L1-L2-L3) flash twice – Activated Charcoal Filte