GLX390 Hood
Instructions Manual
www.rangemaster.co.uk
Resumen del contenido incluido en la página 2
Instructions Manual INDEX RECOMMENDATIONS AND SUGGESTIONS......................................................................................................................3 CHARACTERISTICS..............................................................................................................................................................4 INSTALLATION ...................................................................................................................................
Resumen del contenido incluido en la página 3
RECOMMENDATIONS AND SUGGESTIONS The Instructions for Use apply to several versions of this appliance. Accord- ingly, you may find descriptions of individual features that do not apply to your specific appliance. INSTALLATION • The manufacturer will not be held liable for any damages resulting from incor- rect or improper installation. Check that the mains voltage corresponds to that indicated on the rating plate fixed to the inside of the hood. For Class I appliances, check that the
Resumen del contenido incluido en la página 4
CHARACTERISTICS Dimensions 4 EN 4
Resumen del contenido incluido en la página 5
Components Ref. Q.ty Product Components 1 1 Hood Body, complete with: Controls, Light, Blower, Filters 2.1 1 Upper Section 2.2 1 Lower Section 8 1 Directional Air Outlet grille 9 1 Flange 10 1 Adapting ring ø 120-125 mm 14.1 2 Air Outlet Connection Extension 15 1 Air Outlet Connection 16 1 Filter cover Ref. Q.ty Installation Components 7.2.1 2 Upper Chimney Section Fixing Brackets 7.3 1 Air Outlet Connection Support
Resumen del contenido incluido en la página 6
INSTALLATION Wall drilling and bracket fixing 7.2.1 7.3 200 200 11a 1 1 180 180 2 2 11 12a A=Min 250 Max 400 On the wall, draw • a Vertical line up to the ceiling or upper limit, at the centre of the area in which the Hood is to be fitted; a Horizontal line at a minimum of (710 mm + A) above the Cooker Top. Mark a point (1) on the horizontal line, 200 mm to the right of the vertical reference line. Repeat this operation on the other side, checking that the two marks are l
Resumen del contenido incluido en la página 7
Mounting the hood body Open the ducting panels. Disconnect the panel from the hood canopy by slid- ing the fixing pin lever.(A) Remove the metal grease filters by turning the han- dles provided. Adjust the two screws Vr, on brackets 11a, to a mini- mum.(B) Hook the hood canopy onto the two brackets 11a. From inside the hood canopy, adjust the screws Vr to set the Hood Canopy level. Tighten the safety screw 11. Connections DUCTED VERSION AIR EXHAUS
Resumen del contenido incluido en la página 8
RECIRCULATION VERSION AIR OUTLET Insert the connection extension pieces laterally 14.1 in connec- tion 15.
Insert the Connector 15 into the Support bracket 7.3 and fix it with a screw. Make sure that the outlet of the extension pieces 14.1 is hori- zontally and vertically aligned with the chimney outlets. Connect the air outlet connection 15 to the hood body outlet using either a flexible or rigid pipe ø 150 mm, the choice of which is left to the installer.
Resumen del contenido incluido en la página 9
USE Control Panel The hood can be switched on pushing directly onto the requested speed without firstly having to select 0/1 button. KEY LED FUNCTIONS L 0/1 Light Turns lighting on and off. T1 0/1 Motor on First speed. When pressed for about 1 seconds the motor is switched off. Flashing 24h Changeover This is enabled by pressing and holding the button for approximately 5".It al- lows a suction level of 100 m3/h with a noise level of just 28dB(A).Can
Resumen del contenido incluido en la página 10
MAINTENANCE REMOTE CONTROL (OPTIONAL) The appliance can be controlled using a remote control powered by a 1.5 V carbon-zinc alkaline batteries of the standard LR03- AAA type. Do not place the remote control near to heat sources. Used batteries must be disposed of in the proper manner. Ducting panels Open the ducting panels. Disconnect the panel from the hood canopy by sliding the fix- ing pin lever. Clean the outside using a damp cloth and neutral liquid deter- gent. Cle
Resumen del contenido incluido en la página 11
Grease filters CLEANING METAL SELF- SUPPORTING GREASE FILTERS Alarm signal reset Switch off the lights and extractor motor. Press button T3 for at least 3 seconds, until the leds start to flash. Cleaning the filters The filters are washable and must be cleaned when the LED S1 lights up or at least every 2 months of operation, or more fre- quently for particularly heavy usage. Remove the filters one at a time holding them up with one hand and pulling the handle downwards with
Resumen del contenido incluido en la página 12
Activated charcoal filter (Recirculation version) The filter is not washable and cannot be regenerated. It must be replaced when led S1 flashes or at least every 4 months. The alarm signal will only light up when the extractor motor is switched on. Alarm signal activation In Recirculation version Hoods, the Filter saturation alarm can be enabled on installation or at a later date. Turn the Lights and the suction Motor off. Disconnect the Hood using the Main switch or the double-pole s
Resumen del contenido incluido en la página 13
Resumen del contenido incluido en la página 14
Resumen del contenido incluido en la página 15
Resumen del contenido incluido en la página 16
AGA RANGEMASTER LTD. 436004184_ver1