Resumen del contenido incluido en la página 1
KOBE Brand Range Hood
Model No. CH9130SQB
CH9136SQB
CH9142SQB
CH9148SQB
CH-191 SERIES – 9” HEIGHT
INSTALLATION INSTRUCTIONS
AND OPERATION MANUAL
Resumen del contenido incluido en la página 2
- READ AND SAVE THESE INSTRUCTIONS - CONTENTS Important Safety Instructions.................................................................................................1 Components of Package.......................................................................................................3 Installation.............................................................................................................................4 Operation Instructions.......
Resumen del contenido incluido en la página 3
IMPORTANT SAFETY INSTRUCTIONS - PLEASE READ THIS SECTION CAREFULLY BEFORE INSTALLATION - WARNING – TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR PERSONAL INJURY, OBSERVE THE FOLLOWING: 1) Installation and electrical wiring must be done by qualified professionals and in accordance with all applicable codes and standards, including fire-rated construction. 2) When cutting or drilling into wall or ceiling, be careful not to damage electrical wiring or other hidden utilities.
Resumen del contenido incluido en la página 4
What to Do In The Event Of a Range Top Grease Fire SMOTHER FLAMES with a close fitting lid, cookie sheet, or metal tray, and then turn off the burner. KEEP FLAMMABLE OR COMBUSTIBLE MATERIAL AWAY FROM FLAMES. If the flames do not go out immediately, EVACUATE THE AREA AND CALL THE FIRE DEPARTMENT or 911. NEVER PICK UP A BURNING PAN – You May Get Burned. DO NOT USE WATER, including wet dishcloths or towels – a violent steam blast will result. Use an extinguisher ONLY if: a)
Resumen del contenido incluido en la página 5
COMPONENTS OF PACKAGE (Must keep all material for returns or refunds) RANGE HOOD BOX ORIGINAL KIT – Model No. RA1020DC (Sold Separately) KOBE Range Hood - 1 KOBE Adjustable Duct Cover - 1 Warranty Registration Card - 1 Screws Package – 1 Instructions Manual - 1 Duct Cover-Mounting Bracket – 1 Baffle Filter - 2 (for 30”, 36”, 42” hood) Hood-Mounting Bracket – 1 - 3 (for 48” hood) Bottom Casing - 1 (for 30” hood)
Resumen del contenido incluido en la página 6
INSTALLATION PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING Calculation before Installation Calculate the length of the installation, before installing the hood. (All calculation is measure in inches.) - FOR UNDER THE CABINET - TABLE 1 A = Height of Floor to Ceiling B = Height of Floor to Counter Top (Standard: 36”) C = Preferred Height of Counter Top to Hood Bottom (Recommended 27” to 30”) D = Height of Hood E = Height of the Cabinet - FOR STA
Resumen del contenido incluido en la página 7
SAFETY W ARNING HOOD MAY HAVE VERY SHARP EDGES; PLEASE WEAR PROTECTIVE GLOVES IF IT IS NECESSARY TO REMOVE ANY PARTS FOR INSTALLING, CLEANING OR SERVICING. NOTE: BE CAREFUL WHEN USING ELECTRICAL SCREWDRIVER, DAMAGE TO THE HOOD MAY OCCUR. Installation Contents Under the Cabinet.................................................................................................................6 Stand Alone .........................................
Resumen del contenido incluido en la página 8
UNDER THE CABINET INSTALLATION Preparation before Installation Figure 1 NOTE: TO AVOID DAMAGE TO YOUR HOOD, PREVENT DEBRIS FROM ENTERING THE VENT OPENING. Decide the location of the venting pipe from the hood to the outside. Refer to Figure 1. A straight, short venting run will allow the hood to perform more efficiently. Try to avoid as many transitions, elbows, and long run as possible. This may reduce the performance of the Figure 2 hood.
Resumen del contenido incluido en la página 9
Figure 5 Ductwork Installation 5. Use aluminum or steel pipe to connect the 6” round plastic exhaust on the hood to the ductwork above. Use duct tape to make all joints secure and air tight. Refer to Figure 4. 6. To convert ductwork to 7” round, attached 7” round adapter (provided) to the 6” round plastic exhaust. Wiring to Power Supply SAFETY W ARNING Figure 6 RISK OF ELECTRICAL SHOCK. THIS RANGE HOOD MUST BE PROPERLY GROUNDED. MAKE SURE THI
Resumen del contenido incluido en la página 10
STAND ALONE INSTALLATION ***This installation only applied with the Figure 8 purchase of a duct cover (Model No. RA1020DC). Preparation before Installation NOTE: TO AVOID DAMAGE TO YOUR HOOD, PREVENT DEBRIS FROM ENTERING THE VENT OPENING. Decide the location of the venting pipe from the hood to the outside. (Figure 1) A straight, short venting run will allow the hood to perform more efficiently. Figure 9 Try to avoid as many transitions,
Resumen del contenido incluido en la página 11
mounting screws (not provided) on the Figure 12 wall, leaving 1/8” away from the wall. 2. Align hood-mounting bracket to the screws on the wall and hook hood into place as shown in Figure 11. Tighten screws to secure hood to the wall. 3. For safety purposes, extra knockout holes on the back of the hood are provided. Knockout the holes. Remove the baffle filters and attach screws to the wall by accessing underneath the hood. CAUTION: MAKE SURE HOOD IS SUCUR
Resumen del contenido incluido en la página 12
all joints secure and air tight as shown on Figure 16 Figure 14. 7. To convert ductwork to 7” round, attached 7” round adapter (provided) to the 6” round plastic exhaust. 8. Slide the inner duct cover up 2 inches before sliding the entire duct cover onto the hood. Refer to Figure 15. 9. Adjust the height of the inner duct cover to the duct cover-mounting bracket. Secure the inner duct cover with two (4x8 mm) screws (provided). 10. Fasten outer duct cover
Resumen del contenido incluido en la página 13
OPERATION INSTRUCTIONS This KOBE hood is equipped with four electronic controls with a 10-second standby startup & 30- second delay shutoff, two powerful centrifugal turbine impellers with baffle filters, and two bright 12-volt 20-watt halogen lights. The four electronic controls are Light Control, Speed Control A, Speed Control B and the Power Control (On/Off). Refer to Figure 19.
Resumen del contenido incluido en la página 14
MAINTENANCE For the optimal level of operation, clean the range hood surface and baffles regularly. To Clean Hood Surface CAUTION: NEVER USE ABRASIVE CLEANERS, PADS, OR CLOTHS. *** Regular care will help preserve its fine appearance. 1. Use only mild soap or detergent solutions. Dry surfaces using soft cloth. 2. If hood looks splotchy (stainless steel hood), use an orange base cleaner to clean the surface of the hood. Avoid cleaner to get on the control switches. Onl
Resumen del contenido incluido en la página 15
SPECIFICATIONS MODEL / SIZE CH9130SQB / 30” CH9136SQB / 36" CH9142SQB / 42” CH9148SQB / 48” COLOR # 304 Commercial Grade Stainless Steel CONSUMPTION / AMPERE CH9130SQB – 232W / 2.21A CH9136SQB – 232W / 2.21A CH9142SQB – 253W / 2.38A CH9148SQB – 258W / 2.41A VOLTAGE 120V 60Hz NUMBER OF MOTORS 2 DESIGN 18-Gauge Seamless / Satin Finish FAN TYPE Twin Turbine Impeller EXHAUST Top 6” Round Top 7” Round Adapter CONTROLS Electronic Control (4 Buttons) –
Resumen del contenido incluido en la página 16
MEASUREMENTS & DIAGRAMS All measurements in ( ) are millimeters. All inch measurements are converted from millimeters. Inch measurements are estimated. - FOR UNDER THE CABINET - MODEL NO.: CH9130SQB MODEL NO.: CH9136SQB CH9142SQB CH9148SQB - FOR STAND ALONE (WITH OPTIONAL DUCT COVER) - ***Hood-Mounting Bracket
Resumen del contenido incluido en la página 17
***Rear Knockout Holes MODEL NO.: CH9130SQB MODEL NO.: CH9136SQB CH9142SQB CH9148SQB 15
Resumen del contenido incluido en la página 18
PARTS LIST MODEL NO.: CH9130SQB CH9136SQB CH9142SQB CH9148SQB NO. DESCRIPTION MODEL /SIZE PART NO. 1 7” Round Adapter C1-0505-0004 2 6” Round Plastic Exhaust C1-0505-0001 3 Plastic Plate C1-0507-0201 4 Hood Casing CH9130SQB 10-1930A CH9136SQB 10-1936A CH9142SQB 10-1942A CH9148SQB 10-1948A 5 Halogen Light Unit (12V 20W Max.) C1-0403-0101 6 Control Unit C1-0501-0101 7 Control Board C1-0404-0401-A 8 Transformer Support C1-0201-1930 9 Transformer (Motor)
Resumen del contenido incluido en la página 19
(Optional Duct Cover) ORIGINAL KIT NO. DESCRIPTION MODEL /SIZE PART NO. 01 Duct Cover-Mounting Bracket C1-0203-0002 02 Screw (TS 4 x 8 mm) C1-0708-0006 03 Duct Cover RA1020DC 12-02000-430-51 04 Hood-Mounting Bracket C1-0221-0330 05 Screw (3/16” x 3/8”) C1-0707-0001 06 Rubber Stand C1-0511-0201 07 Screw (TS 4 x 8 mm) C1-0708-0006 RECIRCULATING KIT NO. DESCRIPTION MODEL /SIZE PART NO. 01 Duct Cover-Mounting Bracket C1-0203-0002 02 T-Head Box A Box C1-0241-1930-FA B
Resumen del contenido incluido en la página 20
MODEL NO.: CH9130SQB CH9136SQB 18