ENGLISH ES L
See page 2 Vea la página 21
I n s t a l l a t i o n G u i d e
aoñp
™
90055/90056/90057 Low Profile Bath Ventilator with Light
READ and SAVE THESE INSTRUCTIONS
41719-013/29/2006
41719_EngS_3.29.06.indd 1 3/29/06 9:16:18 PM
Resumen del contenido incluido en la página 2
W a r n i n g TO REDUCE THE RISK OF ELECTRIC SHOCK OR INJURY, OBSERVE THE FOLLOWING: such as those published by the National Fire Prevention 1. Use this unit only in a manner intended by the manufacturer. Association (NFPA), and the American Society for Heating, If you have questions, contact the manufacturer at the phone Refrigeration and Air-Conditioning Engineers (ASHRAE), and number or address listed in the warranty. the local code authorities. 2. Before installing, servicing, or c
Resumen del contenido incluido en la página 3
Check all the parts. 95044-01-000 D If damaged, call 95029-01-000 1-888-830-1326 E for replacements. 75191-01-000 F 03242-07-133 x4 A G 95491-02-000 H B 74508-03-133 * x2 I 3/8” Cable Connector 95511-01/02/03-000 J C * 75184-01-133 K x2 I Extra Screws 94997-01/02/03-000 L NOTE: Strain relief cable connector 7517-01/02/03-000 * M must be installed. Not Included. Included. Tools Needed. Estimated assembly time: 30 to 60 minutes Before Installation NOTE: Remove all packing materials
Resumen del contenido incluido en la página 4
3 4 H E Remove the motor/blower from the housing. Remove packing material. 6 5 Remove the pre-loaded screw tip covers. Back out the pre-loaded screw tips until flush with the side of the housing. 7 8 F G Remove the wiring cover screw. Remove the wiring cover. 41719-013/29/2006 41719-01 3/29/2006 4 41719_EngS_3.29.06.indd 4 3/29/06 9:16:23 PM
Resumen del contenido incluido en la página 5
9 10 E C B Pop out the first wiring access slug. Use second if needed. Insert the strain relief into the housing and secure with the washer. Choose Installation Option For New Construction - attaching to joist go to step A11, page 5 For New Construction - suspended between joists go to step B11, page 8 For Existing Construction - accessible from above go to step C11, page 11 For Existing Construction - accessible only from below go to step D11, page15 New Construction – attaching to joist A12
Resumen del contenido incluido en la página 6
A13 Pull wires through the strain relief. A14 Ground Black Green 2 Pin Bare Copper White A Black Main Switch 1 (AC In) Fan Motor White White 3 Pin Black Light Light *Option Black Switch 2 (AC In) *Option Fan & Main Light Together Connect wires as shown. A0 16 A15 E F G Connect 4” duct and vent to the outside. Tape joints. Install the wiring cover plate. Make sure all If ducting does not fit securely, an adapter may need wiring connections are inside the box or under to be purchased. the w
Resumen del contenido incluido en la página 7
ON OFF 0000 A18 0000 A17 H Reinstall the motor by inserting the tabs and pushing up Connect wiring from the motor to the wiring cover plate. into position. Make sure the wires are not pinched between the motor and the housing. A19 A20 I Secure the motor by tightening the 2 screws. Turn on the power source. A21 A22 Go to step E1 on page 17 to attach grille. Test the motor. If the motor does not run, check the plug connection. 41719-01 3/29/2006 41719-01 3/29/2006 7 41719_EngS_3.29.06
Resumen del contenido incluido en la página 8
New Construction – suspended between joists B12 B11 E D 5/8 5/8 1/2 1/2 Slide the mounting rails into brackets. Position the correct depth mark at the bottom edge of the joist based on the thickness of your sheetrock. B13 B14 1/8" Bit E Mark position of screws by using holes as a template. Drill a hole in the center of each outline. B15 B16 Insert screws, leaving space between the screw Attach the rails onto the screws. head and the joist. Screws are not provided. 41719-013/29/2006
Resumen del contenido incluido en la página 9
B17 B18 Tighten screws. Pull wires through the strain relief. Ground B19 Black Green 2 Pin Bare Copper White A Black Main Switch 1 (AC In) Fan Motor White White 3 Pin Black Light Light *Option Black Switch 2 (AC In) *Option Fan & Main Light Together Connect wires as shown. B20 B21 F G Connect 4” duct and vent to the outside. Tape joints. Install the wiring cover plate. Make sure all wiring If ducting does not fit securely, an adapter may need connections are inside the box or under the to
Resumen del contenido incluido en la página 10
ON OFF B22 B23 H H Connect wiring from the motor to the wiring cover plate. Reinstall the motor by inserting the tabs and pushing up into position. Make sure the wires are not pinched between the motor and the housing. B24 B25 I Turn on the power source. Secure the motor by tightening the 2 screws. B26 B27 Go to step E1 on page 17 to attach grille. Test the motor. If the motor does not run, check the plug connection. 41719-01 3/29/2006 41719-013/29/2006 10 41719_EngS_3.29.06.indd
Resumen del contenido incluido en la página 11
8” Existing Construction – accessible from above EXISTING FAN NO EXISTING FAN C11 OR Remove an existing fan and check to make sure the Use the motor housing as a template to mark position. opening is large enough to accommodate the new motor housing (8”x 8.5”). C12 E D Cut out an opening for the housing. Slide the mounting rails into brackets. C13 C14 5/8 5/8 1/2 1/2 Position the correct depth mark at the bottom edge of the Mark position of screws by using holes as a template. joist based on t
Resumen del contenido incluido en la página 12
C15 C16 1/8" Bit Drill a hole in the center of each outline. Insert screws, leaving space between the screw head and the joist. Screws are not provided. C18 C17 Attach the rails onto the screws. Tighten screws. C19 C20 Connect 4” duct and vent to the outside. Tape joints. Pull wires through the strain relief. If ducting does not fit securely, an adapter may need to be purchased. 41719-013/29/2006 41719-01 3/29/2006 12 41719_EngS_3.29.06.indd 12 3/29/06 9:16:45 PM
Resumen del contenido incluido en la página 13
C21 Tighten the strain relief screws. Ground C22 Black Green 2 Pin Bare Copper White A Black Main Switch 1 (AC In) Fan Motor White White 3 Pin Black Light Light *Option Black Switch 2 (AC In) *Option Fan & Main Light Together Connect wires as shown. C23 C24 H F G Install the wiring cover plate. Make sure all wiring Connect wiring from motor the motor connections are inside the box or under the to the wiring cover plate. wiring cover plate. 41719-013/29/2006 41719-01 3/29/2006 13 4
Resumen del contenido incluido en la página 14
ON OFF C25 C26 I H Reinstall the motor by inserting the tabs and pushing up Secure the motor by tightening the 2 screws. into position. Make sure the wires are not pinched between the motor and the housing. C27 C28 Turn on the power source. Test the motor. If the motor does not run, check the plug connection. C29 Go to step E1 on page 17 to attach grille. 41719-01 3/29/2006 41719-01 3/29/2006 14 41719_EngS_3.29.06.indd 14 3/29/06 9:16:50 PM
Resumen del contenido incluido en la página 15
Existing Construction – accessible only from below EXISTING FAN D11 D12 E Remove an existing fan and check to make sure the open- Move the housing into position above the ceiling. ing is large enough to accommodate the new motor hous- ing (8”x 8.5”). D13 D14 Attach existing ducting to duct connector. Tape joints. Pull wires through strain relief. If ducting does not fit securely, an adapter may need to be purchased. D15 E Install the housing flush with the sheetrock and secure by tightening th
Resumen del contenido incluido en la página 16
D16 Ground Black Green 2 Pin Bare Copper White A Black Main Switch 1 (AC In) Fan Motor White White 3 Pin Light Black Light *Option Black Switch 2 (AC In) *Option Fan & Main Light Together Connect wires as shown. D17 D18 F H G Install the wiring cover plate. Connect wiring from the motor to the wiring cover plate. D20 D19 I H Reinstall the motor by inserting the tabs and pushing up Secure the motor by tightening the 2 screws. into position. Make sure the wires are not pinched between the mot
Resumen del contenido incluido en la página 17
ON OFF D21 D22 Test the motor. If the motor does not run, check the plug Turn on the power source. connection. D23 Go to step E1 on page 17 to attach grille. Attaching the Grille E1 E2 J K L M Remove the thumbscrews. Remove glass dome. 41719-01 3/29/2006 41719-01 3/29/2006 17 41719_EngS_3.29.06.indd 17 3/29/06 9:16:58 PM
Resumen del contenido incluido en la página 18
E3 E4 J J Connect wiring harness. Slide light mount over posts. E6 E5 J K Install 2 Max 60 Watt A15 bulbs (Not Included). Attach thumbscrews. WARNING: To reduce the risk of electrical shock, all 4 thumbscrews MUST be properly installed. E7 E8 L M Align glass dome and push up. Screw glass dome into position. 41719-01 3/29/2006 41719-01 3/29/2006 18 41719_EngS_3.29.06.indd 18 3/29/06 9:17:02 PM
Resumen del contenido incluido en la página 19
Trouble Shooting Problem: Fan does not come on. Solution: • Hunter F an Bath Ventilators are extremely quiet. To confirm that the fan is running, place your hand near the vents to feel the air movement. • Turn power on, replace fuse, or reset breaker. • Check all plug connections to be sure they are secure. • Check the wiring to make sure it matches the wiring diagram. Problem: Light does not come on. Solution: • Replace the light bulb with a new bulb. • Turn power on, repl
Resumen del contenido incluido en la página 20
Warranty Hunter Fan Company Bath Exhaust Fan LIMITED WARRANTY Hunter Fan Company makes the following limited warranty to the original user or consumer purchaser of this Hunter bath exhaust fan: If any part of your Hunter bath exhaust fan (except for glass fixtures and light bulbs) fails at any time within one year after the date of sale to you due to a defect in material or workmanship, we will repair or, at our option, replace the defective part free of charge for parts and labor performed