Resumen del contenido incluido en la página 1
R410A MULTI SPLIT SERIES ROOM AIR CONDITIONER
WALL MOUNTED TYPE INDOOR UNITS
OPERATION & INSTALLATION MANUAL
AS072XVERA
AS092XVERA
AS122XVERA
AS182XVERA
Please read this manual carefully before using this air conditioner.
Please keep this manual safely for future use.
No.0010576789 B
Resumen del contenido incluido en la página 2
Contents Cautions ............................................................................................. 1-2 Safety precautions............................................................................... 3-5 Parts and Functions ........................................................................... 6-7 Operation......................................................................................... 8-18 Notes for safety ..........................................................
Resumen del contenido incluido en la página 3
Cautions Disposal of the old air conditioner Consult your local authorities for the name and address of the waste materials collecting Before disposing an old air conditioner centers and waste paper disposal services that goes out of use, please make sure it's nearest to your house. inoperative and safe. Unplug the air conditioner in order to avoid the risk of Safety Instructions and Warnings child entrapment. Before starting the air conditioner, read the It must be noticed that air conditioner
Resumen del contenido incluido en la página 4
Cautions All electrical repairs must be carried out 4. The wiring method should be in line with by qualified electricians. Inadequate repairs the local wiring standard. may result in a major source of danger for the user of the air conditioner. 5. The power cable and connecting cable are self-provided.The requirement of the Do not damage any parts of the air connecting cable: conditioner that carry refrigerant by piercing or perforating the air conditioner's Connecting cable Model tubes wi
Resumen del contenido incluido en la página 5
Safety precautions Carefully read the following information in order to operate the air conditioner correctly. Below are listed three kinds of Safety Cautions and Suggestions. WARNING! Incorrect operations may result in severe consequences of death or serious injuries. CAUTION! Incorrect operations may result in injuries or machine damages; in some cases may cause serious consequences. INSTRUCTIONS: These information can ensure the correct operation of the machine. Be sure to conform with the fo
Resumen del contenido incluido en la página 6
Safety precautions CAUTIONS! Don't operate the air-conditioner with damp Conditioner should not be used for any other hands. purpose other than airconditioning. Otherwise will be shocked. Don't use air-conditioner for any other special purposes, e.g. the preservation and protection of food, animals, plants, pecision apparatus as Only use correctly-typed fuse. well as work of art, otherwise the qualities May not use wire or any other materials of these stuffs may be damaged. replacing fuse, oth
Resumen del contenido incluido en la página 7
Safety precautions CAUTIONS ON INSTALLATION Please ask the dealer or specialist to install, never try by the users themselves. After the installation please be sure of the following conditions. Please call dealer to install the air-conditioner. Incorrect installation may cause water leaking, shock and fire hazard. CAUTION ! Air-conditioner can't be installed in the envi- Connect earthing wire. ronment with inflammable gases because the Earthing wire should not be con- inflammable gases near to a
Resumen del contenido incluido en la página 8
Parts and Functions INDOOR UNIT FRONT VIEW Air inlet grille Front panel Louver Display board Signal receiver INDOOR UNIT BACK VIEW Mounting plate Heat preservation pipe Connecting pipes Drainage pipes 6
Resumen del contenido incluido en la página 9
Parts and Functions REMOTE CONTROLLER YR-H65 14 TEMP 4 TIMER 20 Used to set temp.,temp. 21 Used to select range:16 C~30 C TIMER ON, TIMER 22 B A OFF, TIMER 15 Timer ON/OFF display 27 19 ON/OFF. o2 16 Fan speed and air sending 28 18 direction display 5 LOCK 17 Used to lock buttons 25 24 and LCD display. LOW MID HIGH AUTO 23 26 6 RESET 16 17 Swing direction display 14 TEMP Used to reset the 15 ON 18 Room temperature display controller back to 11 OFF 12 normal condition. HEALTH FAN 19 Sleep sta
Resumen del contenido incluido en la página 10
Operation MODE HEALTH AIRFLOW Clock set SLEEP FRESH SWING CLOCK SET When unit is started for the first time TIMER STERILIZE 3 1 2 and after replacing batteries in remote controller, clock should be adjusted as follows: RESET CODE LIGHT LOCK Press CLOCK button, "AM"or "PM" flashes. Press or to set correct time. Each press will increase or decrease 1 min . If the button is kept pressed, time will change quickly. After time setting is confirmed, press SET, "AM" and "PM" stop flashing, whil
Resumen del contenido incluido en la página 11
2 Operation Auto 1 Press ON/OFF button Unit starts running. The previous status appears on the display A (except. TIMER, SLEEP mode) 2 Press MODE button. For each press, operation mode changes as follows: Remote TEMP AUTO COOL DRY FAN HEAT controller ON 3 FAN HEALTH OFF Select Auto run, 5 4 MODE HEALTH AIRFLOW " " appears and auto run starts. SLEEP FRESH SWING 3 Select temp. button SET CLOCK Press TEMP button Every time the button is pressed, temp. TIMER STERILIZE setting increases 1
Resumen del contenido incluido en la página 12
3 2 Operation Cooling 1 Press ON/OFF button A Unit starts running. The previous status appears on the display (except. TIMER, SLEEP mode) 2 Press MODE button. For each press, operation mode changes as follows: TEMP ON Remote HEALTH OFF FAN 1 5 4 AUTO COOL DRY FAN HEAT controller MODE HEALTH AIRFLOW Select cooling operation, Shows" " SLEEP FRESH SWING Cooling operation starts. CLOCK SET TIMER STERILIZE 3 Select temp. button Press TEMP button Every time the button is pressed, temp. LIGHT
Resumen del contenido incluido en la página 13
3 2 Operation Dry 1 Press ON/OFF button Unit starts running. A The previous status appears on the display (except. TIMER, SLEEP mode) 2 Press MODE button. For each press, operation mode changes as follows: Remote TEMP AUTO COOL DRY FAN HEAT ON controller FAN HEALTH OFF 1 4 5 MODE HEALTH AIRFLOW Select Drying operation shows" " Dry operation starts SLEEP FRESH SWING CLOCK SET 3 Select temp. button TIMER STERILIZE Press TEMP button Every time the button is pressed, temp. setting increases 1 C
Resumen del contenido incluido en la página 14
2 Operation Fan 1 Press ON/OFF button A Unit starts running. The previous status appears on the display (except. TIMER, SLEEP mode) 2 Press MODE button. For each press,operation mode changes as follows: TEMP ON FAN HEALTH OFF Remote 1 4 AUTO COOL DRY FAN HEAT controller MODE HEALTH AIRFLOW SLEEP FRESH SWING CLOCK SET Select Fan operation shows " ", Fan operation starts. TIMER STERILIZE 3 Press FAN button. For each press, fan speed changes as RESET CODE LIGHT LOCK follows: LOW MID HIGH Unit r
Resumen del contenido incluido en la página 15
3 2 Operation Heating Note: For cooling only type, this function is invalid. 1 Press ON/OFF button A Unit starts running. The previous status appears on the display (except. TIMER, SLEEP mode) 2 Press MODE button. For each press,operation mode changes as follows: TEMP ON FAN HEALTH OFF 1 5 AUTO COOL DRY FAN HEAT MODE HEALTH AIRFLOW SLEEP FRESH SWING SET CLOCK Select Heating operation " " appears and Heating operation starts. TIMER STERILIZE 3 Select temp. button RESET CODE LIGHT LOCK Press T
Resumen del contenido incluido en la página 16
2 Operation Air flow adjustment Swing louvers (Vertical louvers) (Horizontal louvers) Up and down Side from side A Position 1 Position 1 Position 2 Position 2 Position 3 TEMP Position 3 ON Position 4 FAN HEALTH OFF Position 4 MODE HEALTH AIRFLOW Position 5 SLEEP FRESH SWING [COOL/DRY/FA Position 5 N/AUTO(COOL) SET Position 6 CLOCK HAVE NOT] TIMER STERILIZE (AUTO SWING) Position 6 Position 7 RESET CODE LIGHT LOCK Position 8 Fixed position Press the SWING again to fix the vertical louve
Resumen del contenido incluido en la página 17
Operation Sleep Remote control unit Before go to bed, you can press the Sleep button, the air conditioner will operate in comfortable sleep mode to make your sleep more comfortable. The Sleep running starts The Sleep running stops Usage of the Sleep function After starting, set the Run mode and press the Sleep About 6 hours button. Run mode Raise 1 C 1 hour 1. In cooling and dry Raise 1 C After starting of the Sleep operation, the temperature will 1 hour Close down be raised for 1 C higher than
Resumen del contenido incluido en la página 18
Operation Timer on/off operation Remote control unit TIMER operation Set Clock correctly before starting Timer operation (refer to page 2) You can let unit start or stop automatically at following times: Before you wake up in the morning, or get back from outside or after you fall asleep at night. TIMER ON/OFF (1) After unit start, select your desired operation mode. Operation mode will be displayed on LCD. (2) TIMER mode selection Press TIMER button to change TIMER mode. Every time the button i
Resumen del contenido incluido en la página 19
2 Operation Timer on-off function Remote controller operation TIMER ON-OFF (1) After unit start, select your desired operation mode. Operation mode will be displayed on LCD. (2) TIMER mode selection Press TIMER button to change TIMER mode. Every time the button is pressed, display changes as follows: ON OFF ON OFF BLANK AM AM Remote 12:00 12:00 12:00 12:00 PM PM controller TIMER ON TIMER OFF TIMER ON-OFF Select your desired TIMER mide (TIMER ON or TIMEROFF) ON or OFF A will flash. (3) Timer sett
Resumen del contenido incluido en la página 20
Operation Health & Fresh Air operation A Health operation After turning on the unit and set the desired working mode. Press the Health button, the LCD will display " ", the unit begins health operation (start the negative ion generation device). Press the Health button again, the " " displayed on the LCD disappears, health operation is cancelled (turn off the negative ion generation device). TEMP Note: When indoor fan motor does not work, the unit will ON automatically turn off negat