Resumen del contenido incluido en la página 1
DUCT TYPE AIR CONDITIONER
Operation & Instruction
Manual
AD182AMBEA
AD242AMBEA
AD242AMERA
AD28NAMBEA
AD36NAMBEA
AD42NAMBEA
No. 0010572489
G
Please read this operation manual before using the air conditioner.
Please keep this manual carefully and safely.
Resumen del contenido incluido en la página 2
Table of Contents Cautions 2 3-5 Safety Precautions Parts and Functions 6 Malfunction 7-8 Care and Maintenance 9 For Preparation of Heating("Hot Keep") 10 Is The Unit Installed Correctly 11 Installation Manual For Indoor Unit 12-18 1
Resumen del contenido incluido en la página 3
Cautions Disposal of the old air conditioner important observations relating to the assembly, operation and maintenance of the Before disposing an old air conditioner that air conditioner. goes out of use, please make sure it's inoperative and safe. Unplug the air The manufacturer does not accept conditioner in order to avoid the risk of responsibility for any damages that may arise child entrapment. due to non-observation of the following instruction. It must be noticed that air conditioner sys
Resumen del contenido incluido en la página 4
Safety Precautions Before starting to use the system, read carefully this"SAFETY PRECAUTIONS" to ensure a proper operation of the system. Safety precautions described here are classified to " WARNING" and " CAUTION". Precautions which are shown in the column of " WANING" means that an improper handing could lead to a grave result like a death, serious injury, etc. However, even if precautions are shown in the column of " CAUTION", a very serious problem could occur depending on
Resumen del contenido incluido en la página 5
Safety Precautions CAUTION Do not wash the air conditioner with water. Make sure to use a fuse of proper electric Do not install the system where the air outlet reaches directly the flora and fauna. rating. It could cause electric shocks. Use of steel or copper wire in place of a fuse is strictly It will not be good for their health. prohibited because it could result in a trouble or fire accident. It is strictly prohibited to place a container of Neither stand on the air conditioner nor Do not
Resumen del contenido incluido en la página 6
Safety Precautions The machine is adaptive in following situation 1. Applicable ambient temperature range: Rated Maximum Minimum DB C 27 32 18 Indoor WB C 19 23 14 Cooling DB C 35 43 10 outdoor WB C 24 26 6 20 27 15 DB C Indoor Heating 15 -- -- WB C 7 24 -7 DB C outdoor 6
Resumen del contenido incluido en la página 7
Parts and Functions Duct Air outlet Air inlet AD182AMBEA AD242AMBEA AD242AMERA AD28NAMBEA Duct Air outlet Air inlet AD36NAMBEA AD42NAMBEA 6
Resumen del contenido incluido en la página 8
Malfunction please check the following things about your air conditioner before making a servie call. Unit fails to start Is the power source Is city supply power in Isn't the signal receiving Isn't the earth leakage switch adjust cut in? normal? section exposed to the breaker in action? direct sunlight or strong ON illumination? It is dangerous. Turn off OFF Power the power supply switch stoppage? immediately and contact Power supply switch is the sales dealer. not ON. Cooling or heating is not
Resumen del contenido incluido en la página 9
Shuru Shuru Malfunction The followings are not malfunction When the air conditioner is started, when the compressor starts or Water flowing stops during operation or when the air conditioner is stopped, it sound is heard. sometimes sounds "shuru shuru" or "gobo gobo". It is the flowing sound of the refrigerant, and it is not a trouble. Cracking sound is heard. This is caused by heat expansion or contraction of plastics. It smells. Air which blows out from the indoor unit sometimes smells. The s
Resumen del contenido incluido en la página 10
Care and Maintenance Points to observe Turn off the power supply switch. Do not touch with wet hand. Do not use hot water or volatileliquid. Do not ON use! Thinner Benzine OFF Tooth powder CAUTION Do not open the inlet grill until fan stops completely. Fan will continue rotating for a while by the law of inertia after operation is being stopped. Cleaning CAUTION Do not dry the air filter with fire. Do not run the air conditioner without the air filter. Care and Cleaning of the unit Clean w
Resumen del contenido incluido en la página 11
For Preparation of Heating("Hot Keep") "HOT KEEP"is operated in the following cases. When heating is started: In order to prevent blowing out of cool wind, the indoor unit fan stopped according to the room temperature which heating operation is started. Wait for approx. 2 to 3 minute, and the operation will be automatically changed to the ordinary heating mode. Defrosting operation (in the heating mode): When it is liable to frost. the heating operation is stopped automatically for 5 to 12 minut
Resumen del contenido incluido en la página 12
Is The Unit Installed Correctly Confirm the following items for safe and comfortable use of air conditioner. The installation work is to be burden on the sales dealer, and do not conduct it by yourself. Installation place Avoid installing the air conditioner Install the unit at well ventilated Install the air conditioner firmly on near the place where possibility of place. the foundation that can fully support inflammable gas leakage exists. the weight of the unit. Explosion (Ignition) may occur
Resumen del contenido incluido en la página 13
Installation Manual For Indoor Unit 1. Safety precautions Please read these "Safety Precautions" first then accurately execute the installation work. Though the precautionary points indicated herein are divided under two headings, WARNING and , those points which are related to the strong possibility of an installation done in error CAUTION resulting in death or serious injury are listed in the W section. However ARNING , there is also a
Resumen del contenido incluido en la página 14
Installation Manual For Indoor Unit NOTICE All Wiring of this installation must comply with NATIONAL, STATE AND LOCAL REGULATIONS. These instructions do not cover all variations for every kind of installation circumstance. Should further information be desired or should particular problems occur, the matter should be referred to your local distributor. WARNING BE SURE TO READ THESE INSTRUCTIONS CAREFULLY BEFORE BEGINNING INSTALLATION. FAI- LURE TO FOLLOW THESE INSTRUCTIONS COULD CAUSE SERIOUS IN
Resumen del contenido incluido en la página 15
Installation Manual For Indoor Unit (4) Preparation for suspending the unit (a) Size of hole at ceiling and position of hanging bolts 57 A 137 (Hanging bolt position) 30 B (Ceiling hole size) C (Ceiling ~ panel (Panel dimensions) wrap dimensions) Unit: mm Dimensions A B C Model AD36NAMBEA 1406 1600 1660 AD42NAMBEA AD182AMBEA AD242AMBEA 1000 1180 1240 AD242AMERA AD28NAMBEA (b) Hanger bolts installation Use care of the piping direction when the unit is installed. I
Resumen del contenido incluido en la página 16
Installation Manual For Indoor Unit Hanging bolt (5) Installation of indoor unit M10 nut M10 washer Fix the indoor unit to the hanger bolts. If required, it is possible to suspend the unit to the beam, etc. Directly by use of the bolts without using the hanger bolts. M10 spring washer Main unit Note When the dimensions of main unit and ceiling holes does not match, it can be adjusted with the slot holes of hanging bracket. Piping side Adjusting to the levelness Supply water (a) Adjust the out-
Resumen del contenido incluido en la página 17
Installation Manual For Indoor Unit Secure the elevation as high as possible (d) When constructing drain piping for several units, position the (approx. 100 mm) common pipe about 100 mm below the drain outlet of each unit as shown in the sketch. Use VP-30(11/4") or thicker pipe A downhill grade of VP 30 for this purpose. 1/100 or more (e) Be sure to provide heat insulation to hard PVC pipes of indoor placement. 290~325mm (f) Do not ever provide an air vent. Right overhead (g) The height of the d
Resumen del contenido incluido en la página 18
Installation Manual For Indoor Unit (7) Installation work for air outlet ducts Air conditioner main unit Heat inlet duct insulation (optional or Suction panel Ceiling surface marketat item) (Silent panel) B Special blowout A Blowout duct C special inlet (option) (Optional or marketed item) (Option) (with air filter) Hole for check Calculate the draft and external static pressure and select the length, shape and blowout. A Blowout duct 2-spot, 3-spot and 4-spot with 200 type
Resumen del contenido incluido en la página 19
Installation Manual For Indoor Unit 5. Electric wiring WARNING DANGER OF BODILY INJURY OR DEATH TURN OFF ELECTRIC POWER AT CIRCUIT BREAKER OR POWER SOURCE BEFORE MAKING ANY ELECTRIC CONNECTIONS. GROUND CONNECTIONS MUST BE COMPLETED BEFORE MAKING LINE VOLTAGE CONNECTIONS. (1) Selection of size of power supply and interconnecting wires. Precautions for Electric wiring Electric wiring work should be conducted only by authorized personnel. Do not connect more than three wires to the terminal block.
Resumen del contenido incluido en la página 20
HAIER GROUP Qingdao Haier Air Conditioner Electric Co., Ltd. Address: Haier Garden ,Qianwangang Road , Economic Development Zone, Qingdao ,Shandong 266500, P.R.China Web Site: http://www.haier.com