Resumen del contenido incluido en la página 1
SMART-STAT-II Remote Control Kits
- Installation and Operating Instructions -
FCC REQUIREMENTS
INTRODUCTION
The remote control system can be operated thermo-
WARNING: CHANGES OR MODIFICATIONS TO
statically or manually from the transmitter. The system
THIS UNIT NOT EXPRESSLY APPROVED BY
operates on radio frequencies (RF) within a 20 foot range.
THE PARTY RESPONSIBLE FOR COMPLIANCE
Can be used with DSI, IPI or Standing Pilot systems.
COULD VOID THE USER'S AUTHORITY TO
OPERATE THE EQUIPMENT.
This
Resumen del contenido incluido en la página 2
INSTALLATION INSTRUCTIONS REMOTE RECEIVER Important: The remote receiver should be posi- Installing Electrical Service to the Junction Box tioned close to front in right or left corner. WARNING: TURN ELECTRICAL POWER OFF The remote receiver is powered by 110-120VAC. It plugs AT THE CIRCUIT BREAKER BEFORE BEGIN- into a standard polarized duplex receptacle. NING THIS INSTALLATION. NOTE: Some appliances do not have a cover plate. Locating Receiver and Operating Functions Instead, there is a hole th
Resumen del contenido incluido en la página 3
NOTE: The remote receiver will only respond to Wiring Electronic Spark Ignitions the transmitter when the 3-position slide button on The remote control receiver can be wired, in series, to a the remote receiver is in the Remote position. If 24VAC transformer, which controls an electronic igni- the system does not respond to the transmitter on tion module (see Figure 3). initial use, see section Matching Security Codes. 1. With the slide switch in the ON position, the system 1. Connect the neutra
Resumen del contenido incluido en la página 4
1. LOW - Battery power low. Replace batteries within two weeks. 2. TIMER - Indicates time remaining before system shuts off, when timer-programmed, 9 - hour maximum setting. 3. MODE - Indicates operation MODE of system. ON indicates the system is on, either manually or thermostatically. THERMO indicates the system will automatically cycle ON/OFF, depending on programmed SET tem- perature. OFF indicates the entire system is LCD DISPLAY SCREEN turned off. ON 4. SET - Indicates desired SET room t
Resumen del contenido incluido en la página 5
2. Press the UP or DOWN button to select the desired room temperature. The highest SET temperature is 0 0 0 99 F (37 C). The lowest SET temperature is 45 F 0 (7 C). NOTE: To prevent repeated thermo-cycling of the gas appliance, the sensing unit in the transmitter will only activate the remote receiver when the temperature 0 0 change exceeds 1 F (1/2 C) above or below the SET (desired) temperature. When the transmitter is in the THERMO mode, it should be kept away from direct sources of heat s
Resumen del contenido incluido en la página 6
T o “reset” the RECEIVER and operate the fireplace system: Child Proof Lockout (CP) The transmitter contains a “Child Proof” lockout feature 1. Press the MODE button on the transmitter. The that prevents unauthorized use of the remote control. word ON must display on the LCD screen. The COM- To access the “Child Proof” activation button, remove MUNICATION -SAFETY operation is overridden and cover on BACK of transmitter. To activate LOCKOUT: the system will return to normal operation depend- 1.
Resumen del contenido incluido en la página 7
Electronic Ignition System GENERAL INFORMATION 1. Slide the 3-position button on the remote receiver to Transmitter Wall Bracket the ON position. The spark electrode should begin The transmitter can be hung on a wall using the bracket sparking to ignite the pilot (the pilot may ignite after provided. Locate the bracket on an inside wall sufficiently only one spark). After the pilot flame is lit, the main far away from direct sources of heat such as a fire- gas valve should open and the main gas
Resumen del contenido incluido en la página 8
NEUTRAL HOT IGNITION MODULE 3 VAC INTERMITTENT PILOT IGNITOR I S TRANSFORMER WHITE 3 VAC ORANGE GROUND TO FIREPLACE PLUG IN CHASSIS JUMPER WIRE BATTERY PACK (TO BROWN) THERMOSTAT WIRE ASSEMBLY VALVE Figure 7. Intermittent Pilot Ignition (IPI) Wiring Diagram PIEZO PILOT THERMOSTAT WIRE ASSEMBLY THERMOCOUPLE RED VALVE Figure 8. Standing Pilot Ignition Wiring Diagram 8 RED WHITE ORANGE GREEN
Resumen del contenido incluido en la página 9
INTERMITTENT IGNITION MODULE PILOT I PLUG-IN 3 VAC IGNITOR 3V TRANSFORMER ON/OFF S WALL SWITCH FLAME SPARKER/ SENSOR IGNITION MODULE (3V) WHT ORG VALVE LOW VOLTAGE GROUND TO SEE NOTE 1 FIREPLACE CHASSIS GROUND REMOTE CONTROL HOT NEUTRAL WHITE WIRE CAN BE PLUGGED INTO ANY OF #1-#5 BLACK WIRE CAN BE LOCATIONS PLUGGED INTO ANY OF PIGGYBACK ON THE #1 - #5 LOCATIONS ON/OFF SWITCH NEUTRAL SIDE ON THE HOT SIDE TRANSFORMER 3 VAC PLUG IN VALVE Figure 9. Intermittent Pilot Ignition (IPI) Wiring Diagram
Resumen del contenido incluido en la página 10
Remote Control Wiring Diagrams IGNITION MODULE 3 VAC 110V I INTERMITTENT PILOT IGNITOR S REMOTE RECEIVER TRANSFORMER WHITE 3 VAC ORANGE GROUND TO FIREPLACE PLUG IN CHASSIS JUMPER WIRE (TO BROWN) VALVE BATTERY PACK Figure 11. Remote Control Intermittent Pilot Ignition (IPI) Wiring Diagram PILOT PIEZO THERMOCOUPLE RED VALVE 110V REMOTE RECEIVER Figure 12. Remote Control Standing Pilot Ignition Wiring Diagram 10 BL CK A RED WHITE ORANGE GREEN