Resumen del contenido incluido en la página 1
INSTRUCTION MANUAL
MODEL 200EH/EM
NITROGEN OXIDES ANALYZER
© TELEDYNE ADVANCED POLLUTION INSTRUMENTATION
9480 CARROLL PARK DRIVE
SAN DIEGO, CA 92121-5201
USA
Toll-free Phone: 800-324-5190
Phone: 858-657-9800
Fax: 858-657-9816
Email: api-sales@teledyne.com
Website: http://www.teledyne-api.com/
04521
Rev. C
DCN 5731
Copyright 2007-2010 14 May 2010
Teledyne Advanced Pollution Instrumentation
Resumen del contenido incluido en la página 2
Resumen del contenido incluido en la página 3
Teledyne API - Model 200EH/EM Operation Manual Safety Messages SAFETY MESSAGES Your safety and the safety of others is very important. We have provided many important safety messages in this manual. Please read these messages carefully. A safety message alerts you to potential hazards that could hurt you or others. Each safety message is associated with a safety alert symbol. These symbols are found in the manual and inside the instrument. The definition of these symbols is described
Resumen del contenido incluido en la página 4
This page intentionally left blank. ii 04521C (DCN5731)
Resumen del contenido incluido en la página 5
Teledyne API - Model 200EH/EM Operation Manual Table of Contents TABLE OF CONTENTS 1. M200EH/EM Documentation....................................................................................................................................................1 1.1. Using This Manual............................................................................................................................................................1 2. Specifications, Approvals and Warranty..............
Resumen del contenido incluido en la página 6
5.11. Alarm Relay Option (OPT 67).......................................................................................................................................51 5.12. Special Software Features ...........................................................................................................................................53 5.12.1. Maintenance Mode Switch..........................................................................................................................
Resumen del contenido incluido en la página 7
Teledyne API - Model 200EH/EM Operation Manual Table of Contents 6.13.5.1. The Analog I/O Configuration Submenu. ....................................................................................................113 6.13.5.2. Analog Output Signal Type and Range Selection.......................................................................................115 6.13.5.3. Turning the Analog Output Over-Range Feature ON/OFF.........................................................................
Resumen del contenido incluido en la página 8
9.3.2. Changing the O Dryer Particulate Filter...............................................................................................................179 3 9.3.3. Maintaining the External Sample Pump................................................................................................................180 9.3.3.1. Rebuilding the Pump.....................................................................................................................................180 9.3.3.2. C
Resumen del contenido incluido en la página 9
Teledyne API - Model 200EH/EM Operation Manual Table of Contents 10.4.13. Power-up Circuit ...............................................................................................................................................221 10.5. Power Distribution &Circuit Breaker ...........................................................................................................................222 10.6. Communications Interface............................................................
Resumen del contenido incluido en la página 10
11.5.12. PMT Sensor......................................................................................................................................................263 11.5.13. PMT Preamplifier Board ...................................................................................................................................263 11.5.14. High Voltage Power Supply ...........................................................................................................................
Resumen del contenido incluido en la página 11
Teledyne API - Model 200EH/EM Operation Manual List of Figures Figure 5-11: M200EH/EM Ethernet Card .........................................................................................................50 Figure 5-12: M200EH/EM Rear Panel with Ethernet Installed.........................................................................50 Figure 5-13: Alarm Relay Output Pin Assignments..........................................................................................52 Figure 6-6-1: F
Resumen del contenido incluido en la página 12
Figure 10-10-25: Power Distribution Block Diagram ........................................................................................... 222 Figure 10-10-26: Interface Block Diagram ........................................................................................................... 223 Figure 10-10-27: M200EH/EM Front Panel Layout.............................................................................................. 224 Figure 10-10-28: Keyboard and Display Interface Block
Resumen del contenido incluido en la página 13
Teledyne API - Model 200EH/EM Operation Manual List of Tables Table 6-6: Front Panel LED Status Indicators for iDAS................................................................................63 Table 6-7: iDAS Data Channel Properties ....................................................................................................64 Table 6-8: iDAS Data Parameter Functions..................................................................................................65 Table 6-9: M20
Resumen del contenido incluido en la página 14
LIST OF APPENDICES APPENDIX A - VERSION SPECIFIC SOFTWARE DOCUMENTATION APPENDIX A-1: M200EH/EM Software Menu Trees, Revision F.0 APPENDIX A-2: Setup Variables For Serial I/O, Revision F.0 APPENDIX A-3: Warnings and Test Functions, Revision F.0 APPENDIX A-4: M200EH/EM Signal I/O Definitions, Revision F.0 APPENDIX A-5: M200EH/EM iDAS Functions, Revision F.0 APPENDIX A-6: Terminal Command Designators, Revision F.0 APPENDIX B - M200EH/EM SPARE PARTS LIST APPENDIX C - REPAIR QUESTIONNA
Resumen del contenido incluido en la página 15
Teledyne API - Model 200EH/EM Operation Manual M200EH/EM Documentation 1. M200EH/EM DOCUMENTATION Thank you for purchasing the Model 200EH/EM Nitrogen Oxides Analyzer! The documentation (part number 04521) for this instrument is available in several different formats: Printed format, or; Electronic format on a CD-ROM. ® ® The electronic manual is in Adobe Systems Inc. “Portable Document Format” (PDF). The Adobe Acrobat ® Reader software, which is necessary to view these files, can b
Resumen del contenido incluido en la página 16
M200EH/EM Documentation Teledyne API - Model 200EH/EM Operation Manual 6.0 Operation Instructions Step by step instructions for operating the analyzer. 7.0 Calibration Procedures General information and step by step instructions for calibrating your analyzer. 8.0 EPA Protocol Calibration Because there is no single, standard method for EPA equivalency in application where high concentrations of NO are measured, no specific EPA calibration/validation method is included in this manual. x 9
Resumen del contenido incluido en la página 17
Teledyne API - Model 200EH/EM Operation Manual Specifications, Approvals and Warranty 2. SPECIFICATIONS, APPROVALS AND WARRANTY 2.1. M200EH/EM OPERATING SPECIFICATIONS Table 2-1: Model 200EH/EM Basic Unit Specifications Min/Max Range 200EH: Min: 0-5 ppm; Max: 0-5000 ppm (Physical Analog Output) 200EM: Min: 0-1 ppm; Max: 0-200 ppm 3 Measurement Units ppm, mg/m (user selectable) Zero Noise <20 ppb (RMS) Span Noise <0.2% of reading above 20 ppm Lower Detectable Limit 40 ppb (2x noise as
Resumen del contenido incluido en la página 18
Specifications, Approvals and Warranty Teledyne API - Model 200EH/EM Operation Manual 2.2. CE MARK COMPLIANCE Emissions Compliance The Teledyne-Advanced Pollution Instrumentation Nitrogen Oxides Analyzers M200EH/EM, M200EH/EMH and M200EH/EMM were tested and found to be fully compliant with: EN61326 (1997 w/A1: 98) Class A, FCC Part 15 Subpart B Section 15.107 Class A, ICES-003 Class A (ANSI C63.4 1992) & AS/NZS 3548 (w/A1 & A2; 97) Class A. Tested on January 02-06, 2003 at CKC Laboratorie
Resumen del contenido incluido en la página 19
Teledyne API - Model 200EH/EM Operation Manual Specifications, Approvals and Warranty THE WARRANTIES SET FORTH IN THIS SECTION AND THE REMEDIES THEREFORE ARE EXCLUSIVE AND IN LIEU OF ANY IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR PARTICULAR PURPOSE OR OTHER WARRANTY OF QUALITY, WHETHER EXPRESSED OR IMPLIED. THE REMEDIES SET FORTH IN THIS SECTION ARE THE EXCLUSIVE REMEDIES FOR BREACH OF ANY WARRANTY CONTAINED HEREIN. API SHALL NOT BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGE
Resumen del contenido incluido en la página 20
04521C (DCN5731)