Resumen del contenido incluido en la página 1
SPLIT TYPE ROOM AIR CONDITIONER
OPERATION MANUAL
HSU-09HEA03/(BP)
HSU-12HEA03/(BP)
Please read this operation manual before using the air conditioner.
0010518526
Resumen del contenido incluido en la página 2
Cautions Disposal of the old air conditioner Safety Instructions and Warnings Before disposing an old air conditioner that Before starting the air conditioner, read the goes out of use, please make sure it's inop- information given in the User's Guide caref- erative and safe. Unplug the air conditioner ully. The User's Guide contains very impor- in order to avoid the risk of child entrapment. tant observations relating to the assembly, operation and maintenance of the air It must be noticed that
Resumen del contenido incluido en la página 3
Cautions 7. The appliance is not intended for use Do not obstruct or cover the ventilation by young children or infirm persons grille of the air conditoner.Do not put fingers without supervision. or any other things into the inlet/outlet and swing louver. 8. Young children should be supervised to ensure that they do not play with Do not allow children to play with the air the applience. conditioner.In no case should children be allowed to sit on the outdoor unit. 9.Please
Resumen del contenido incluido en la página 4
Parts and Functions Indoor Unit Outlet Display board Inlet Air filter(inside) Air Purifying Filter (inside) Power plug Inlet grille Horizontal flap Anion generator (adjust up and down air flow. (inside) Don't adjust it manually) Vertical blade (adjust left and right air flow) Actual inlet grille may vary from the one shown in the manual according to the product purchased Outdoor Unit HSU-09HEA03/(BP) HSU-12HEA03/(BP) OUTLET CONNECTING PIPING AND ELECTRICAL WIRING INLET DRAIN HOSE 3
Resumen del contenido incluido en la página 5
Parts and Functions Display board Remote controller 1 6 7 2 ON OFF A 8 U o AM T 25 1 26 4 1 8 9 O PM 5 C 3 9 4 7. SIGNAL SENDING display 10 8. TIMER OFF display 11 9. TIMER ON display ON/OFF TEMP 10. CLOCK display 5 11. TEMP display 12 12. POWER ON/OFF 19 Used for unit start and stop. MODE SET 13. MODE 20 13 Used to select COOL,DRY,HEAT operation 14. FAN TIMER FAN Used to select fan speed AUTO, HI, MED, LO 21 15. HOUR 14 Used to set clock and timer setting. 15 16. SWING CLOCK SWING Used to set
Resumen del contenido incluido en la página 6
Operation Remote controller's operation When in use, put the signal transmission head directly to the receiver hole on the indoor unit. The distance between the signal transmission head and the receiver hole should be within 7m without any obstacle as well. Don't throw the controller, prevent it from being damaged. When electronic-started type fluorescent lamp or change-over type fluorescent lamp or wireless telephone is installed in the room, the receiver is apt to be disturbed in receivering t
Resumen del contenido incluido en la página 7
Operation Cool Operation (1) Unit start Press ON/OFF button, unit starts. Previous operation status appears on display. (Not Timer setting) (2) Select operation mode Press MODE button. For each press, operation mode changes as follows: ON/OFF TEMP COOL DRY HEAT 1 4 MODE SET Unit will run in operation mode displayed on LCD. 2 Stop display at your desired mode. FAN TIMER 3 (3) Select temp. setting SWING CLOCK Press TEMP button. o Every time the button is pressed, temp. setting increases 1 C o HEAL
Resumen del contenido incluido en la página 8
Operation Heat Operation (1) Unit start Press ON/OFF button, unit starts. Previous operation status appears on display. (Not Timer setting) (2) Select operation mode Press MODE button. For each press, operation mode changes as follows: COOL DRY HEAT ON/OFF TEMP Unit will run in operation mode displayed on LCD. 3 1 3 5 Stop display at your desired mode. MODE SET (3) Select temp. setting 2 FAN TIMER Press TEMP button. o 4 Every time the button is pressed, temp. setting increases 1 C o SWING CLOCK
Resumen del contenido incluido en la página 9
Operation Dry Operation (1) Unit start Press ON/OFF button, unit starts. (2) Select operation mode Press MODE button. For each press, operation mode changes as follows: HEAT COOL DRY ON/OFF TEMP Unit will run in operation mode displayed on LCD. 3 1 3 6 Stop display at your desired mode. MODE SET (3) Select temp. setting 2 FAN TIMER Press TEMP button. o Every time the button is pressed, temp. setting increases 1 C 4 o Every time the button is pressed, temp. setting decreases 1 C SWING CLOCK Unit
Resumen del contenido incluido en la página 10
Operation (5) Air flow direction adjustment After operation mode is selected, horizontal flap will open automatically according to the mode. Referring to the Fig. COOL o About 10 Up and down (Use remote controller) Left and right air flow adjustment Press SWING button, horizontal flap will move (manual) Move the vertical blade by a knob on air within the range shown in the Fig. Press SWING conditioner to adjust left and right direction button stop it at a fixed position. referring to Fig. o Abo
Resumen del contenido incluido en la página 11
Operation TIMER Operation Set Clock correctly before starting Timer operation You can let unit start or stop automatically at following times: Before you wake up in the morning, or get back from outside or after you fall asleep at night. TIMER ON/OFF (1)After unit start, select your desired operation mode. Operation mode will be displayed on LCD. Power indicator on indoor unit lights up. (2)TIMER mode selection ON Press TIMER button to change TIMER mode. Every time the button is pressed, display
Resumen del contenido incluido en la página 12
Operation POWER/SOFT Operation POWER Operation When you need rapid heating or cooling, you can use this funciton. ON/OFF TEMP Selecting of POWER operation Press POWER/SOFT button. Every time the button is pressed,display MODE SET changes as follows: BLANK FAN TIMER SOFT POWER Stop the display at SWING CLOCK In POWER operation status: In COOL mode, fan speed automatically runs in HI mode HEALTH POWER/SOFT for 15 min then returns to original status setting. To cancel POWER operation LOCK RESET P
Resumen del contenido incluido en la página 13
Operation Emergency operation and test operation Emergency Operation: Carry out this operation only when the remote controller is defective or lost. When the emergency operation switch is pressed, a" Pi "sound starts once, which means the start of this operation. In this operation, it is not possible to change the settings of temperature and air flow speed, it is Pi also impossible to do an operation by the timer. Follow the requirements below. Room Timer Designated Air flow Operation temper
Resumen del contenido incluido en la página 14
Maintenance Replacement of Air Purifying Filter 1.Open the lnlet Grille Prop up the inlet grille by using a small device named grille-support which located in the right side of the ind- oor unit. 2.Detach the standard air filter Slide the knob slightly upward to release the filter, then withdraw it. 3.Attach Air Purifying Filter Put air purifying filter appliances into the Detach old Air Purifying Filter right and left filter frames. 4.Attach the standard air filter (Necessary installation)
Resumen del contenido incluido en la página 15
Maintenance For Smart Use of The Air Conditioner Setting of proper room Do not block the air inlet temperature or outlet Proper temperature Close doors and windows Use the timer effectively during operation During cooling operation prevent the penetration of direct sunlight with curtain or blind If the unit is not to be used Use the louvers effectively for a long time, turn off the power supply main switch. OFF 14
Resumen del contenido incluido en la página 16
Cautions Safety Instruction Please read the following Safety Instructions carefully prior to use. The instructions are classified into two levels, WARNING and CAUTION according to the seriousness of possible risks and damages as follows. Compliance to the instructions are strictly required for safety use. Installation WARNING Please call Sales/Service Shop for the Installation. Do not attempt to install the air conditioner by yourself because improper works may cause electric shock, fire, water
Resumen del contenido incluido en la página 17
Cautions WARNING When abnormality such as burnt-small found, Use an exclusive power source with a immediately stop the operation button and circuit breaker contact sales shop. STRICT OFF ENFORCEMENT Connect power supply cord Use the proper voltage Do not use power supply cord to the outlet completely extended or connected in halfway STRICT STRICT PROHIBITION ENFORCEMENT ENFORCEMENT Take care not to damage Do not insert objects into the air Do not use power supply cord the power supply cord. in
Resumen del contenido incluido en la página 18
Trouble shooting Before asking for service, check the following first. Phenomenon Cause or check points The system does not restart When unit is stopped, it won't restart immediately until 3 minutes have elapsed immediately. to protect the system. When the electric plug is pulled out and reinserted, the protection circuit will work for 3 minutes to protect the air conditioner. During unit operation or at stop, a swishing or gurgling noise may be heard. At first 2-3 minutes after unit start, this