Resumen del contenido incluido en la página 1
.
Connect with Confidence
MultiView
NEC 600
Receiver
Quick Reference
&
Setup Guide
Magenta Research
128 Litchfield Road, New Milford, CT 06776 USA
(860) 210-0546 FAX (860) 210-1758
www.magenta-research.com
Resumen del contenido incluido en la página 2
MAGENTA MULTIVIEW™ SERIES © 1998-2009 by Magenta Research All rights reserved. Magenta Research 128 Litchfield Road New Milford, CT 06776 USA This document and the Magenta Research products to which it relates, and the copyright in each, is the property of Magenta Research. Neither the document nor the products may be reproduced by any means, in whole or in part, without the prior written permission of Magenta Research. Magenta Research makes no wa
Resumen del contenido incluido en la página 3
CONTENTs . Contents Chapter Page 1. Specifications...................................................................................................2 2. Introduction ........................................….........................................................3 2.1 Overview................................................................................…..............
Resumen del contenido incluido en la página 4
MAGENTA MULTIVIEW™ SERIES 1. Specifications Cable Required: Category 5, 5e, 6 shielded or unshielded twisted pair Compliance: CE; FCC Class A, IC Class A Video Support: all supported VESA modes to WUXGA (1920x1200), RGBHV, HDTV modes including 1080p, 1080i, 720p (Note: The NEC 600 does not support component, composite or S-video video signals) Resolution and Refresh Rate:
Resumen del contenido incluido en la página 5
CHAPTER 2: Introduction . 2. Introduction 2.1 Overview This manual covers the Magenta MultiView™ NEC 600 card slot CAT5 Receiver unit. The NEC 600 is intended for use only in compatible NEC displays that have the card slot feature. All signals are input directly into the display so external cabling or power is not required. The NEC 600 card slot receiver supports video, stereo audio and the SAP pollable RS232 option on a single CAT5 cable. In order to support all signals a compati
Resumen del contenido incluido en la página 6
MAGENTA MULTIVIEW™ SERIES 3. Setup and Installation 3.1 Cabling Considerations • We recommend mounting and connecting all cabling to the MultiView™ Series components before applying power. • Make sure that the CAT5 cable you intend to use has been tested to comply with the T568B wiring specification (See Appendix A). 3.2 Making the Connections 3.2.1 CONNECTIONS AND SETUP IN GENERAL This section contains figures showing connections with the specific MultiView™ Series models.
Resumen del contenido incluido en la página 7
CHAPTER 3: SETUP & INSTALLATION. 3.2.2 CONNECTIONS ON THE NEC600 RECEIVER Below the NEC 600 connections are detailed: Figure 3-1. Connections on the MultiView NEC 600. CAT5 CAT5 input output SAP Series Option EQ/SKEW Address Settings/LED Adjustment indicators. & LED indicators See below and See Section 3.3 Appendix C. AUX DB9 used for local receiver control and/or firmware upgrades. This is not a valid display control port.
Resumen del contenido incluido en la página 8
MAGENTA MULTIVIEW™ SERIES 3.3 Video Adjustment 3.3.1 Cable Distance Compensation Settings In order to get the highest quality video signals from your MultiView CAT5 Video System, please follow the instructions and diagrams below: An Image Adjustment Utility is available for download from: http:// www.magenta-research.com/test Simply open in any image browser on a computer. If the image file can not be downloaded, use a utility to draw a black box on a white background. NOTE:
Resumen del contenido incluido en la página 9
CHAPTER 3: Setup and Installation . 3.3.2 Skew Compensation Settings The NEC 600 receiver features integrated skew compensation to adjust for signal timing differences due to differing pair lengths within the CAT5 cable. Using the delay signals, skew may be compensated from 2 to 65 nanoseconds in 2 nanosecond increments on each individual color pair. An image file is available to assist in these settings. See Figure 3-4 for an example. 1. To adjust individual colors, press the EQ/
Resumen del contenido incluido en la página 10
MAGENTA MULTIVIEW™ SERIES 4. Troubleshooting 4.1. Common Problems In most cases, nearly every issue with the MultiView CAT5 Video System can be resolved by checking the CAT5 termination and making sure that it’s pinned to the TIA/EIA 568B wiring specification. However, there may be other problems that cause the system to not perform as it’s designed. Below are solutions to the most common installation errors. Problem: No video signal at the transmitter local port or a
Resumen del contenido incluido en la página 11
. Problem: “Green shift” or “green washout” on multimedia signals. Solution: The standard video/serial model is designed to function with DC coupled signals in which the black level is referenced to 0 volts. Nearly all VGA cards function this way. Some media servers, however, provide AC coupled signals and can cause a green color shift in the video. This
Resumen del contenido incluido en la página 12
MAGENTA MULTIVIEW™ SERIES Appendix A. Cabling Pinouts Table A-1. T568B CAT5 pinout NOTE: The external DB9 connector is intended for console access to the receiver and does not support external SAP RS232 protocol. This connection should not be used to control the display. 10
Resumen del contenido incluido en la página 13
APPENDIX B: Setting Sync modes. Appendix B. Setting Sync Mode The NEC 600 has the capability for fixed and agile sync. The default sync mode setting is for agile sync which replicates the source sync polarity signals. However some displays require a fixed sync polarity that is not possible to change at the video source. 1080P signals may also require this mode if the sync is a very narrow pulse. The following details how to change the sync polarity of the horizontal and vertical sync
Resumen del contenido incluido en la página 14
MAGENTA MULTIVIEW™ SERIES Dec Hex DecHex DecHex DecHex 00 00 64 40 128 80 192 C0 01 01 65 41 129 81 193 C1 Appendix C. SAP 02 02 66 42 130 82 194 C2 03 03 67 43 131 83 195 C3 Addressing 04 04 68 44 132 84 196 C4 05 05 69 45 133 85 197 C5 06 06 70 46 134 86 198 C6 To set the NEC600 SAP address, use 07 07 71 47 135 87 199 C7 the two rotary address knobs on the 08 08 72 48 136 88 200 C8 unit. You will need to convert the 09 09 73 49 137 89 201 C9 100A 744A 1388A 202CA decimal add
Resumen del contenido incluido en la página 15
. Appendix D. Rotary Knob Menu The following diagram details the various configuration settings available through the rotary knob. This is provided to graphically show each menu choice. Mode LED: Range LEDs: Solid Green config status Press knob Press knob > 0.5sec Normal Operation > 5sec (< 5sec) Mode LED Mode LED Configure Video EQ Flashing White Solid White Sync-mode: Range LED1: Adjustement Mode Range LEDs: Agile/fixed Sync-mode EQ setting Status Press knob Press knob > 0.5se
Resumen del contenido incluido en la página 16
MAGENTA MULTIVIEW™ SERIES Magenta Research 128 Litchfield Road, New Milford, CT 06776 USA (860) 210-0546 FAX (860) 210-1758 www.magenta-research.com PN 5310229-01, Rev 01, Jul-2009