Resumen del contenido incluido en la página 1
Magnum CS14 and CSN14 Converter Switches
Corporate Headquarters
GarrettCom, Inc.
47823 Westinghouse Drive
Fremont, CA 94539-7437
Phone (510) 438-9071
Fax (510) 438-9072
Website: http://www.GarrettCom.com
email support@garrettcom.com
100Mb Fiber 10 Mb Fiber
Installation and User Guide
www .. GarrettCom com www ..
Resumen del contenido incluido en la página 2
CS14, CSN14 Series Converter Switch Installation and User Guide (02/06) Magnum™ CS14 and CSN14 Series Converter Switch Installation and User Guide Part #: 84-00101 Rev. A Trademarks GarrettCom, Magnum, Link-Loss-Learn, S-Ring, Convenient Switch, Converter Switch are trademarks and Personal Hub is a registered trademark of GarrettCom, Inc. Ethernet is a trademark of Xerox Corporation NEBS is a trademark of Telcordia Technologies UL is a registered trademark of Underwriters Laboratori
Resumen del contenido incluido en la página 3
CS14, CSN14 Series Converter Switch Installation and User Guide (02/06) Federal Communications Commission Radio Frequency Interference Statement This equipment generates, uses and can radiate frequency energy and if not installed and used properly, that is in strict accordance with the manufacturer's instructions, may cause interference to radio communication. It has been tested and found to comply with the limits for a Class A computing device in accordance with the specifications in
Resumen del contenido incluido en la página 4
CS14, CSN14 Series Converter Switch Installation and User Guide (02/06) Contacting GarrettCom, Inc Please use the mailing address, phone and fax numbers and email address listed below: GarrettCom, Inc. 47823 Westinghouse Drive Fremont, CA 94539 Phone (510) 438-9071 Fax (510) 438-9072 Website: http://www.GarrettCom.com Email: support@garrettcom.com www .. GarrettCom com iii
Resumen del contenido incluido en la página 5
CS14, CSN14 Series Converter Switch Installation and User Guide (02/06) TABLE OF CONTENTS Page 1.0 SPECIFICATIONS ............................................................................... 1 1.1 Technical Specifications ..................................................................... 1 1.2 Summary of models and descriptions:.................................................. 11 2.0 INTRODUCTION ....................................................................
Resumen del contenido incluido en la página 6
CS14, CSN14 Series Converter Switch Installation and User Guide (02/06) 3.7 CS14H and P Series , DC-powered, Installation .............................. 48 3.8 Connecting Ethernet Media ............................................................... 49 3.8.1 Connecting Twisted Pair............................................................ 51 3.8.2 Connecting Fiber Optic ST-type, “twist-lock”........................... 52 3.8.3 Connecting Fiber Optic SC-type, "Snap-In"................
Resumen del contenido incluido en la página 7
CS14, CSN14 Series Converter Switch Installation and User Guide (02/06) 5.4 Shipping and Packaging Information................................................. 68 APPENDIX A: WARRANTY INFORMATION......................................... 69 Revisions Rev A 02/06: Change address to Westinghouse Drive Rev A 05/05: Minor updates on Auto-cross (MDIX) functionality Rev A 10/04: Minor updates on power supply option. Rev A 09/04: Minor updates on UL requirements, and edit. Rev A 07/04: Mino
Resumen del contenido incluido en la página 8
CS14, CSN14 Series Converter Switches Installation and User Guide (02/06) 1.0 SPECIFICATIONS 1.1 Technical Specifications Ports Performance When a port is operating at 100Mbps: Data Rate: 100Mbps When a port is operating at 10 Mbps: Data Rate: 10 Mbps Network Standards 100Mb: Ethernet IEEE 802.3u, 100BASE-TX, 100BASE-FX 10 Mb: Ethernet IEEE 802.3, 10BASE-T Auto-sensing for speed: IEEE 802.
Resumen del contenido incluido en la página 9
CS14, CSN14 Series Converter Switches Installation and User Guide (02/06) Address buffer age-out time: 300 sec. Packet buffers memory: 128KB, dynamically shared on all domains Latency (not including packet time): 100 to 10 Mbps: 5µs 10 to 100Mbps: 15µs Path Delay Value: 50 BT on all ports Maximum Ethernet Segment (or Domain) Lengths 10BASE-T (Unshielded twisted pair) - 100 m (328 ft) 100BASE-TX (CAT 5 UTP) - 100 m (328 ft) 100BASE-FX, half-duplex: (multi-mode)
Resumen del contenido incluido en la página 10
CS14, CSN14 Series Converter Switches Installation and User Guide (02/06) Operating Environment CS14, CSN14: 32ºF to 104ºF (0ºC to 40ºC) CS14H, CSN14H: -13ºF to 140ºF (-25ºC to 60ºC) Long term per agency tests (UL). -40ºF to 149ºF (-40ºC to 85ºC) Short term per IEC Type tests. CS14P, CSN14P: -40ºF to 167ºF (-40ºC to 75ºC) Long term per agency tests (UL). -58ºF to 212ºF (-50ºC to 100ºC) Short
Resumen del contenido incluido en la página 11
CS14, CSN14 Series Converter Switches Installation and User Guide (02/06) Packaging: Enclosure: Rugged sheet metal (Steel). Dimensions of the Switch unit: 3.5 in H x 3.0 in W x 1.0 in D (8.9 cm x 7.6 cm x 2.5 cm) Weight: all models: 4.6 oz. (130g); Power supply, –d, and i: 5.9 oz (170g) –Hd, and Hi: 5.8 oz (165g) –Pd, and -Pi: 7.9 oz (225g) Cooling Method: Convection on the regular model. The hardened (H) fac
Resumen del contenido incluido en la página 12
CS14, CSN14 Series Converter Switches Installation and User Guide (02/06) POWER SUPPLY These products are intended to be supplied by a Listed, Direct Plug-In power unit, marked “Class 2”, or a Listed ITE Power Supply, marked “LPS”, which has suitably rated output voltage (i.e. 9vdc, 12vdc, 24vdc, 48vdc), and suitably rated output current (i.e. 100mA to 500mA).When connected to a 48 V centralized dc source these products shall be provided with a Listed 5 A DC fuse in the supply circuit.
Resumen del contenido incluido en la página 13
CS14, CSN14 Series Converter Switches Installation and User Guide (02/06) International (-i) models. Input: 240vac at 50Hz with IEC 320 connector for the user supplied AC power cord. Output:12vdc, 1Amps Factory Floor (H) Ratings (-25 to 60°C) North America (-Hd) models. Hardened, factory floor temperature rated. Input: 6ft AC power cord to IEC 320 connector on the 100-240vac 47-63Hz external power adapter. Output:12vdc, 1.25Amps International (-Hi) models. Factory floor temperature ra
Resumen del contenido incluido en la página 14
CS14, CSN14 Series Converter Switches Installation and User Guide (02/06) Direct DC POWER SUPPLY : built-in terminal block for +, -, ground along with 12VDC jack 12V DC internal (range of 8.0 to 15V DC),. 24V DC internal (range of 18 to 36V DC),. -48V DC internal (range of 36 to 60V DC), , -, ground. Power Consumption: See Section 3.6. Note 1: the 8-15V DC jack can be used for dual source DC input using an AC adapter and the DC terminal
Resumen del contenido incluido en la página 15
CS14, CSN14 Series Converter Switches Installation and User Guide (02/06) Port Connectors: Two RJ-45 Ports: support 100BASE-TX and 10BASE-T with auto-cross (MDIX). They are shielded 8-pin female connectors for shielded (STP) and unshielded (UTP) Cat 3, 4, 5 cable. One Fiber optic port: On the CSN14 Series it is 10Base-FL with ST connections and on the CS14 series it is 100Base-FX with a “fiber flavor” choice of multimode SC, ST or MTRJ or single mode SSC, SSCL, SST or SLC connectors.
Resumen del contenido incluido en la página 16
CS14, CSN14 Series Converter Switches Installation and User Guide (02/06) LED Indicators (Dual: front and top) POWER: Steady ON when power applied 10/100: Steady ON for 100Mbps; OFF for 10 Mbps LK/ACT: Steady ON for LINK (LK) with no traffic, BLINKING indicates port is transmitting / receiving (ACT). F/H: Steady ON for full-duplex, OFF for half-duplex Mounting options Metal mounting clips for panel mounting: included DIN-Rail mounting option: Mode
Resumen del contenido incluido en la página 17
CS14, CSN14 Series Converter Switches Installation and User Guide (02/06) Agency Approvals and Standards Compliance: UL Listed (UL 60950), cUL, CE, Emissions meets FCC Part 15 Class A. NEBS L3 and ETSI compliant. H and P models: IEEE P1613 Env. Std for Electric Power Substations P models: NEMA TS-2 and TEES for traffic control equipment P models: designed for UL 2043 above-the-ceiling installation IEC61850 EMC and Operating Conditions Class C Power Substations Warranty:
Resumen del contenido incluido en la página 18
CS14, CSN14 Series Converter Switches Installation and User Guide (02/06) 1.2 Summary of models and descriptions: Note: The CSN14 model # consists of the base unit type and the power input. Insert S for sgl-mode The CS14 model # consists of the base unit type, the fiber flavor (ff) and the power input. CSN14 Models (for 10Mb fiber). CSN14-d or -i = two 10/100 RJ-45+ one 10Mb ST Fiber port for office and wiring closet, rated (0 to 40°C) using an external AC power
Resumen del contenido incluido en la página 19
CS14, CSN14 Series Converter Switches Installation and User Guide (02/06) CS14 Models (for 100Mb fiber). CS14-ff-d or -i = two 10/100 RJ-45+ one 10Mb ST Fiber port for office and wiring closet (0 to 40C) using an external AC power supply. CS14H-ff-Hd, Hi = Hardened (H), two RJ-45+ one 10Mb Fiber port for factory floor (-25 to 60C) using a direct DC ( 8-15VDC) and/or external AC hardened power
Resumen del contenido incluido en la página 20
CS14, CSN14 Series Converter Switches Installation and User Guide (02/06) “SC” = 100Base-FX-SC: multi-mode fiber optic with SC type connector, 2km. “SSC”= 100Base-FX-SSC: single-mode fiber optic with SC type connector, 20km. “SSCL”= 100Base-FX-SSCL: single-mode fiber optic with SC type connector, 40km. “ST” = 100Base-FX-ST: multi-mode fiber optic with ST type connector, 2km. “SST” = 100Base-FX-ST: single-mode fiber optic with ST type connector, 2km. “SLC”= 100Base-FX-SLC: single-mode f