Resumen del contenido incluido en la página 1
Enterprise Networking Solution
Installation Guide
Gigabit Unmanaged Switch
TL-SG1048/TL-SG1024
TL-SG1024D/TL-SG1016
TL-SG1016D/TL-SG1008
Resumen del contenido incluido en la página 2
Resumen del contenido incluido en la página 3
COPYRIGHT & TRADEMARKS Specifications are subject to change without notice. is a registered trademark of TP-LINK TECHNOLOGIES CO., LTD. Other brands and product names are trademarks of their respective holders. No part of the specifications may be reproduced in any form or by any means or used to make any derivative such as translation, transformation, or adaptation without permission from TP-LINK TECHNOLOGIES CO., LTD. Copyright © 2012 TP-LINK TECHNOLOGIES CO., LTD. All rights reserved. ht
Resumen del contenido incluido en la página 4
Related Document This Installation Guide is also available in PDF on our website. To obtain the latest documentation and product information, please visit the official website: http://www.tp-link.com About this Installation Guide This Installation Guide describes the hardware characteristics, installation methods and the points that should be attended to during installation. This Installation Guide is structured as follows: Chapter 1 Introduction. This chapter describes the external compo
Resumen del contenido incluido en la página 5
Contents Chapter 1 Introduction ——————————— 01 1.1 Product Overview ...................................................................01 1.2 Features ......................................................................................01 1.3 Appearance ...............................................................................02 Chapter 2 Installation ———————————— 05 2.1 Package Contents ...................................................................05 2.2 Safety Precautions ..........
Resumen del contenido incluido en la página 6
Gigabit Unmanaged Switch ChaCter C Introduction C1C Product Overview The Gigabit Unmanaged Switch provides you with a high-performance, low-cost, easy- to-use, seamless and standard upgrade to boost your old network to 1000Mbps. Increase the speed of your network server and backbone connections, making Gigabit a reality. Power users in the home, office, workgroup, or creative production environment can now move large, bandwidth-intensive files faster. Transfer graphics, CGI, CAD, or multimedia
Resumen del contenido incluido en la página 7
Gigabit Unmanaged Switch C11 ACCearance ■ Front Panel The front panel of TL-SG1048 is shown as the following figure. LEDs 10/100/1000Mbps RJ45 Port Figure 1-1 Front Panel of TL-SG1048 The front panel of TL-SG1024 is shown as the following figure. LEDs 10/100/1000Mbps RJ45 Port Figure 1-2 Front Panel of TL-SG1024 The front panel of TL-SG1024D is shown as the following figure. LEDs 10/100/1000Mbps RJ45 Port Figure 1-3 Front Panel of TL-SG1024D The front panel of TL-SG1016 is shown as the followi
Resumen del contenido incluido en la página 8
Gigabit Unmanaged Switch The front panel of TL-SG1008 is shown as the following figure. LEDs 10/100/1000Mbps RJ45 Port Figure 1-6 Front Panel of TL-SG1008 LEDs LED Status Indication On The Switch is powered on Power Off The Switch is powered off or power supply is abnormal There is a device linked to the corresponding port but On not active Link/Act Flashing The corresponding port is transmitting or receiving data Off There is no device linked to the corresponding port A 1000Mbps device is con
Resumen del contenido incluido en la página 9
Gigabit Unmanaged Switch Power Socket Grounding Terminal Figure 1-8 Rear Panel of TL-SG1024/TL-SG1016 The rear panel of TL-SG1024D/TL-SG1016D is shown as the following figure. Grounding Terminal Power Socket Figure 1-F Rear Panel of TL-SG1024D/TL-SG1016D The rear panel of TL-SG1008 is shown as the following figure. Grounding Terminal Power Socket Figure 1-10 Rear Panel of TL-SG1008 Power Socket Connect the female connector of the power cord here, and the male connector to the AC (Alternating
Resumen del contenido incluido en la página 10
Gigabit Unmanaged Switch ChaCter 1 Installation 11C Package Contents Make sure that the package contains the following items. If any of the listed items is damaged or missing, please contact your distributor. One Switch One Power Cord This Installation Guide Two mounting brackets and the fittings 111 Safety Precautions To avoid any device damage and bodily injury caused by improper use, please observe the following rules. ■ Safety Precautions ■ Keep the power off during the installation. ■
Resumen del contenido incluido en la página 11
TL-SL3428 L2 Lite Managed Switch Gigabit Unmanaged Switch ■ Site Requirements Temperature/Humidity Please keep a proper temperature and humidity in the equipment room. Too high/low humidity may lead to bad insulation, electricity leakage, mechanical property changes and corrosions. Too high temperature may accelerate aging of the insulation materials and can thus significantly shorten the service life of the device. For normal temperature and humidity of the device, please check the follo
Resumen del contenido incluido en la página 12
Gigabit Unmanaged Switch Lightening Protection Extremely high voltage currents can be produced instantly when lightning occurs and the air in the electric discharge path can be instantly heated up to 20,000℃. As this instant current is strong enough to damage electronic devices, more effective lightning protection measures should be taken. ■ Ensure the rack and device are well earthed. ■ Make sure the power socket has a good contact with the ground. ■ Keep a reasonable cabling system and a
Resumen del contenido incluido en la página 13
Gigabit Unmanaged Switch 112 Product Installation ■ Desktop Installation To install the device on the desktop, please follow the steps: 1. Set the device on a flat surface strong enough to support the entire weight of the device with all fittings. 2. Remove the adhesive backing papers from the rubber feet. 3. Turnover the device and attach the supplied rubber feet to the recessed areas on the bottom at each corner of the device. Feet Bottom of the Device Notch Figure 2-1 Desktop Installation
Resumen del contenido incluido en la página 14
Gigabit Unmanaged Switch Rack Figure 2-3 Rack Installation Caution: ■ Please set 5~10cm gaps around the device for air circulation. ■ Please avoid any heavy thing placed on the device. ■ Please mount devices in sequence from the bottom to top of the rack and ensure a certain clearance between devices for the purpose of heat dissipation. Installation 09
Resumen del contenido incluido en la página 15
Gigabit Unmanaged Switch ChaCter 1 Lightning Protection 11C Cabling Reasonably In the actual network environment, you may need cable outdoors and indoors, and the requirements for cabling outdoors and indoors are different. A reasonable cabling system can decrease the damage of induced lightning to devices. Note: It's not recommended using Ethernet cables outdoors. When cabling outdoors, please use a signal lightning arrester. ■ Requirements for Cabling Outdoors ■ Aerial cabling without saf
Resumen del contenido incluido en la página 16
Gigabit Unmanaged Switch ■ Requirements for Cabling Indoors When cabling indoors, keep a certain distance away from the devices that may cause high-frequency interferences, such as down-conductor cable, powerline, power transformer and electromotor. ■ The main cable should be paved in the metal raceway of the access shaft. When cabling, keep the loop area formed by the cable itself as small as possible. ■ Requirements for the distance between Ethernet cable and other pipelines are shown i
Resumen del contenido incluido en la página 17
Gigabit Unmanaged Switch Min Parallel Cable Pave Way Length (mm1 Parallel cabling 300 2~5kVA One is in the grounded metal raceway or metal pipe 150 powerline The both are in the grounded metal raceway or metal 80 pipe Parallel cabling 600 >5kVA One is in the grounded metal raceway or metal pipe 300 powerline The both are in the grounded metal raceway or metal 150 pipe Device Min Distance (m1 Switch case 1.00 Transformer room 2.00 Elevator tower 2.00 Air-conditioner room 2.00 111 Connect to Gr
Resumen del contenido incluido en la página 18
Gigabit Unmanaged Switch Note: The grounding bar and the ground cable are not provided with our product. If needed, please self purchase them. ■ Connecting to the Ground via the Power Supply If the device is installed in the normal environment, the device can be grounded via the PE (Protecting Earth1 cable of the AC power supply as shown in the following figure. Figure 3-2 Connecting to the Ground Note: ■ The figure is to illustrate the application and principle. The power plug you get from
Resumen del contenido incluido en la página 19
Gigabit Unmanaged Switch Grounding T erminal Equipotential Bonding Cable Ground Cable Grounding Bar Figure 3-3 Equipotential Bonding When equipotential bonding, please note that the cable should be copper wrapped 2 Kelly with its area being 6mm at least. The shorter cable the better, and use a grounding bar to establish an equipotential bonding point. Note: The equipotential bonding cable and ground cable are not provided with our product. If needed, please self purchase it. 112 Use Lightnin
Resumen del contenido incluido en la página 20
Gigabit Unmanaged Switch Signal lightning arrester is used to protect RJ45 ports of the device from lightning. When cabling outdoors, please install a signal lightning arrester before connecting the cable to the device. When purchasing or using a signal lightning arrester, please observe the following rules: ■ The port rate of the signal lightning arrester should match the rate of the desired port on the device. If it is not matched, this signal lighting arrester will not work. Purchase a