Resumen del contenido incluido en la página 1
TigerStack 100
Stackable Fast Ethernet Switch
◆ 24 100BASE-FX MT-RJ ports
◆ Optional 100BASE-FX or 1000BASE-X modules
◆ Optional stack module for linking up to four units
◆ 8.8 Gbps of aggregate switch bandwidth
◆ Support for redundant power unit
◆ Up to five port trunks per switch
◆ Port mirroring for non-intrusive analysis
◆ QoS support for two-level priority
◆ Full support for IEEE 802.1Q VLANs
◆ IP Multicasting with IGMP Snooping
◆ Manageable via console, Web, SNMP/RMON
Management Guide
SMC6
Resumen del contenido incluido en la página 2
Resumen del contenido incluido en la página 3
TigerStack 100 Management Guide From SMC’s Tiger line of feature-rich workgroup LAN solutions 38 Tesla Irvine, CA 92618 November 2002 Phone: (949) 679-8000 Pub. # F2.47 150200025700A R01
Resumen del contenido incluido en la página 4
Information furnished by SMC Networks, Inc. (SMC) is believed to be accurate and reliable. However, no responsibility is assumed by SMC for its use, nor for any infringements of patents or other rights of third parties which may result from its use. No license is granted by implication or otherwise under any patent or patent rights of SMC. SMC reserves the right to change specifications at any time without notice. Copyright © 2002 by SMC Networks, Inc. 38 Tesla Irvine, CA 92618 All rights r
Resumen del contenido incluido en la página 5
LIMITED WARRANTY Limited Warranty Statement: SMC Networks, Inc. (“SMC”) warrants its products to be free from defects in workmanship and materials, under normal use and service, for the applicable warranty term. All SMC products carry a standard 90-day limited warranty from the date of purchase from SMC or its Authorized Reseller. SMC may, at its own discretion, repair or replace any product not operating as warranted with a similar or functionally equivalent product, during the applicable
Resumen del contenido incluido en la página 6
LIMITED WARRANTY LIABILITY IN CONNECTION WITH THE SALE, INSTALLATION, MAINTENANCE OR USE OF ITS PRODUCTS. SMC SHALL NOT BE LIABLE UNDER THIS WARRANTY IF ITS TESTING AND EXAMINATION DISCLOSE THE ALLEGED DEFECT IN THE PRODUCT DOES NOT EXIST OR WAS CAUSED BY CUSTOMER’S OR ANY THIRD PERSON’S MISUSE, NEGLECT, IMPROPER INSTALLATION OR TESTING, UNAUTHORIZED ATTEMPTS TO REPAIR, OR ANY OTHER CAUSE BEYOND THE RANGE OF THE INTENDED USE, OR BY ACCIDENT, FIRE, LIGHTNING, OR OTHER HAZARD. LIMITATION OF
Resumen del contenido incluido en la página 7
TABLE OF CONTENTS 1 Switch Management . . . . . . . . . . . . . . . . . . . . . . . . . . .1-1 Configuration Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1 Factory Defaults . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2 Required Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4 Console Port (Out-of-Band) Connections . . . . . . . . . . . . . . . . . 1-4 In-Band C
Resumen del contenido incluido en la página 8
TABLE OF CONTENTS Using a Mirror Port for Analysis . . . . . . . . . . . . . . . . . . . . . . . . 2-44 Configuring Port Trunks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-45 IGMP Multicast Filtering . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-48 Configuring IGMP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-49 Configuring Broadcast Storm Control . . . . . . . . . . . . . . . . . . . . 2-50 Configuring Bridge MIB Extensions . . . . . . . .
Resumen del contenido incluido en la página 9
TABLE OF CONTENTS Expansion Slot . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-10 IP Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-11 SNMP Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-13 SNMP Community . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-13 Trap Managers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Resumen del contenido incluido en la página 10
TABLE OF CONTENTS Configuring IGMP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-43 IP Multicast Registration Table . . . . . . . . . . . . . . . . . . . . . . . . . 3-44 Port Menus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-45 Port Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-45 Port Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-46 Po
Resumen del contenido incluido en la página 11
TABLE OF CONTENTS B Pin Assignments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-1 Console Port Pin Assignments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-1 DB-9 Port Pin Assignments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-1 Console Port to 9-Pin COM Port on PC . . . . . . . . . . . . . . . . . . B-2 Console Port to 25-Pin DTE Port on PC . . . . . . . . . . . . . . . . . . B-2 Glossary Index vii
Resumen del contenido incluido en la página 12
TABLE OF CONTENTS viii
Resumen del contenido incluido en la página 13
CHAPTER 1 SWITCH MANAGEMENT Configuration Options For advanced management capability, the TigerStack 100 management agent provides a menu-driven system configuration program. This program can be accessed by a direct or modem connection to the serial port on the rear panel (out-of-band), or by a Telnet connection over the network (in-band). The management agent is based on SNMP (Simple Network Management Protocol). This SNMP agent permits the switch to be managed from any PC in the network
Resumen del contenido incluido en la página 14
SWITCH MANAGEMENT Required Connections Console Port (Out-of-Band) Connections Attach a VT100 compatible terminal or a PC running a terminal emulation program to the serial port on the switch’s rear panel. Use the null-modem cable provided with this package, or use a null modem connection that complies with the wiring assignments shown in Appendix B of this guide. When attaching to a PC, set terminal emulation type to VT100, specify the port used by your PC (i.e., COM 1~4), and then set comm
Resumen del contenido incluido en la página 15
REQUIRED CONNECTIONS In-Band Connections Prior to accessing the Network Management Module via a network connection, you must first configure it with a valid IP address, subnet mask, and default gateway using an out-of-band connection or the BOOTP protocol. After configuring the switch’s IP parameters, you can access the on-board configuration program from anywhere within the attached network. The on-board configuration program can be accessed using Telnet from any computer attached to the
Resumen del contenido incluido en la página 16
SWITCH MANAGEMENT Factory Defaults The default settings for switch configuration parameters. Each parameter can be changed via the console menus or Telnet. Parameter Default Value System Configuration Management VLAN All IP State USER-CONFIG IP Address 10.1.0.1 NetMark 255.255.0.0 Default Gateway Null User Names admin, guest Password Screen Timeout 10 min Send Authentication Fail Traps Enabled SNMP Community Name public, private Terminal Baud Rate 19200 Port Configuration Flow Control Di
Resumen del contenido incluido en la página 17
FACTORY DEFAULTS Parameter Default Value Path Cost 4 - 1000Mbps ports 19 - 100Mbps ports 100 - 10Mbps ports Port Priority 128 Spanning Tree Protocol Enabled Spanning Tree Fast Forwarding 10/100 Enabled Mbps ports Virtual LANs Acceptable VLAN Frame Type All Configurable PVID Tagging Yes Untagged VLAN Group Assignment 1 VLAN Ingress Filtering False VLAN Learning SVL 1-5
Resumen del contenido incluido en la página 18
SWITCH MANAGEMENT 1-6
Resumen del contenido incluido en la página 19
CHAPTER 2 USING THE SYSTEM CONFIGURATION PROGRAM Login Screen Once a direct connection to the serial port or a Telnet connection is established, the login screen for the on-board configuration program appears as shown below. SSSSSSSSSSSSSSS MMMMM MMMMM CCCCCCCCCCCCCC SSSSSSSSSSSSSSSSS MM MM CCCCCCCCCCCCCCCC SS S MMM MMM CCC CC SS MMMM MMMM CCC SSSSSSSSSSSSSSSS MM MM MM MM CCC SS MM MM MM MM CCC CC SSSMMMMMMMMCCC CC SSSSSSSSSSSSSSSSS MM MMM MM CCCCCCCCCCCCCCCC SSSSSSSSSSSSSSS MMMM MMMMM MMMM CC
Resumen del contenido incluido en la página 20
USING THE SYSTEM CONFIGURATION PROGRAM You should define a new administrator password, record it and put it in a safe place. Select Console Login Configuration from the Management Setup Menu and enter a new password for the administrator. Note that passwords can consist of up to 11 alphanumeric characters and are not case sensitive. Note: Based on the default configuration, a user is allowed three attempts to enter the correct password; on the third failed attempt the current connection is