Resumen del contenido incluido en la página 1
R NETWORK 1275 Danner Dr Tel:330-562-7070
TECHNOLOGIES Aurora, OH 44202 Fax:330-562-1999
NTI INCORPORATED www.networktechinc.com
TM
UNIMUX Series
UNIMUX-DVI-x
USB DVI KVM Switch
Installation and Operation Manual
MAN007 Rev Date 1/04/2008
Resumen del contenido incluido en la página 2
TRADEMARK UNIMUX is a trademark of Network Technologies Inc in the U.S. and other countries COPYRIGHT Copyright © 2000,2008 by Network Technologies Inc. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written consent of Network Technologies Inc, 1275 Danner Drive, Aurora, Ohio 44202. CHANGES The material i
Resumen del contenido incluido en la página 3
TABLE OF CONTENTS INTRODUCTION.............................................................................................................................................................1 MATERIALS ....................................................................................................................................................................2 DEFINITIONS.................................................................................................................
Resumen del contenido incluido en la página 4
NTI UNIMUX SERIES USB KVM SWITCH INTRODUCTION The UNIMUX-DVI-x 4,8 or 16-Port USB DVI KVM switch (UNIMUX) allows access to up to sixteen (16) Windows, MAC, or SUN USB CPUs from one USB keyboard and mouse and a DVI video-enabled monitor. Internal microprocessor circuitry allows all USB CPUs to be booted simultaneously without keyboard error. Port selection is accomplished by front panel push buttons or commands typed on the keyboard. Port lights and status LEDs continuously update o
Resumen del contenido incluido en la página 5
NTI UNIMUX SERIES USB KVM SWITCH MATERIALS Materials supplied with this kit: • NTI UNIMUX-DVI-x (4,8 or 16 ports) USB DVI Video KVM Switch • 120VAC or 240VAC at 50 or 60Hz-5VDC/2.0A AC Adapter • 1- 3 foot HDMI male -to-DVI-D male cable (DVI-HDMI-MM-3) • Line cord, country specific • Rack mount kit • CD with pdf file of this manual • 1- DB9 Female-to-RJ45 Female adapter (models with RS232 option only) • 1- DB25 Female-to-RJ45 Female adapter (models with RS232 option only) • 1
Resumen del contenido incluido en la página 6
NTI UNIMUX SERIES USB KVM SWITCH Front View of UNIMUX-DVI-8 Scan Broadcast Command R 1 2 3 4 5 6 7 8 NTI Network Technologies Inc RS232 ON DDC TM UNIMUX 1 8 3 2 1 46 5 7 Rear View of UNIMUX-DVI-8 9 10 11 8 RS232 CPU 8 CPU 7 CPU 6 CPU 5 CPU 4 CPU 3 CPU 2 CPU 1 VIDEO 8 VIDEO 7 VIDEO 6 VIDEO 5 VIDEO 4 VIDEO 3 VIDEO 2 VIDEO 1 5VDC - + FEATURES AND FUNCTIONS 1. CPU Status LEDs- for visual indication of connection between the
Resumen del contenido incluido en la página 7
NTI UNIMUX SERIES USB KVM SWITCH RACKMOUNTING INSTRUCTIONS This NTI switch was designed to be mounted to a rack or to set on a desktop. It includes rackmount ears to make attachment to a rack easy, and rubber feet to be applied to the bottom of the case if it will instead sit on a flat surface. If this will sit on a flat surface, simply apply the rubber feet to the bottom of the case in each of the 4 corners. To Mount to a Rack 1. Attach the ears to the switch using the
Resumen del contenido incluido en la página 8
NTI UNIMUX SERIES USB KVM SWITCH INSTALLATION 1. It is not necessary to turn the CPUs or monitors OFF during this installation. 2. Connect a HDMI-to-DVI cable (supplied) from a DVI monitor to the HDMI connector labeled with a monitor symbol ( ) on the front of the UNIMUX (See Fig. 3 below.) Front View of UNIMUX-DVI-8 Scan Broadcast Command R 1 2 3 4 5 6 7 8 NTI Network Technologies Inc RS232 ON DDC TM UNIMUX 1 8 DVI-HDMI-MM-3
Resumen del contenido incluido en la página 9
NTI UNIMUX SERIES USB KVM SWITCH 5. Connect each CPU to the USB switch using a DVI-HDMI-MM-x (x=3, 6, 10, or 15 foot) cable for each video connection and a USB-AB-yM (y= .5, 1, 2, 3, or 5 meters) for each input device connection – REQUIRED (not supplied). (See Fig. 5 below.) Cables are available from NTI. 6. Group the input device and monitor interface cables from each CPU, making sure that cables from the first CPU are connected to the
Resumen del contenido incluido en la página 10
NTI UNIMUX SERIES USB KVM SWITCH RS232 Connection If the RS232 option is installed, connect one end of the CAT5 patch cable (supplied) to the port labeled “RS232” on the rear of the UNIMUX. Plug the other end of the CAT5 cable into either the RJ45-to-DB9 or RJ45-to-DB25 adapter supplied, and connect the adapter to the RS232 port on the control terminal. Follow the instruction under “RS232 Control” on page 12 for configuration and use of the RS232 control feature. Rear V
Resumen del contenido incluido en la página 11
NTI UNIMUX SERIES USB KVM SWITCH Power-Up Sequence • Power-up the monitor(s). • The UNIMUX can be powered at any time. Note: It is recommended that the monitor be powered-ON before powering on the UNIMUX in order for DDC information to be properly communicated. • The CPUs can be powered at any time although if a CPU needs a keyboard and/or mouse at power-ON it should be powered after connecting to and powering-ON the UNIMUX. • USB input devices (keyboard and mouse) can be
Resumen del contenido incluido en la página 12
NTI UNIMUX SERIES USB KVM SWITCH USING THE UNIMUX DVI KVM SWITCH Once the UNIMUX is properly connected, the UNIMUX will enable a connection to be made between the CPUs attached to its VIDEO and CPU ports and the monitor and input devices attached to the MONITOR and USB Device ports. The LEDs on the control panel of the UNIMUX will illuminate depending on which port (and corresponding CPU) is being connected to the monitor and input devices. The UNIMUX can be controlled by three m
Resumen del contenido incluido en la página 13
NTI UNIMUX SERIES USB KVM SWITCH (0-9) (0-9) Selects a specific (Pxx would be P01, P02, etc.) P - - x x port Configure port to connect (xx= 01-8 + <0> + <1> will enable function on Port 1 To a MAC CPU x x + <0> + <4> will enable function on Port 4. Keyboard M + + LED's will flash once to confirm command. ) Configure port to connect (xx= 01-8 + <0> + <1> will disable function on Port 1 x x + <0> + <4> will disable function on Port 4. K
Resumen del contenido incluido en la página 14
NTI UNIMUX SERIES USB KVM SWITCH Select Country Code It is possible to configure the UNIMUX to emulate a specific international Sun keyboard regardless of what actual keyboard is connected. This is recommended when the CPU needs the layout code (i.e. a SUN CPU) and the keyboard doesn't have an explicit layout code (i.e. some Windows keyboards). To do this, manually set the UNIMUX to indicate the international keyboard identification number to the CPU using the following procedure;
Resumen del contenido incluido en la página 15
NTI UNIMUX SERIES USB KVM SWITCH RS232 CONTROL (Optional) RS232 enables the UNIMUX to be remotely controlled via RS232. To control the UNIMUX via RS232 the user has three options: • write a program that runs on a PC using the Command Protocol (page 14) • use the NTI Switch Control Program (page 15) provided on the CD • use the SerTest program (page 15) provided on the CD RS232 Connections and Configuration Remote Connection The RS232 Interface (optional) is designed to mee
Resumen del contenido incluido en la página 16
NTI UNIMUX SERIES USB KVM SWITCH DIP SWITCH UNIT ADDRESS Note: The "loop back" RS232 dip switch (RS232 dip 8 7 6 5 switch 1) should be ON for each unit in the chain. OFF OFF OFF OFF 0 (not valid) OFF OFF OFF ON 1 (default) OFF OFF ON OFF 2 OFF OFF ON ON 3 OFF ON OFF OFF 4 OFF ON OFF ON 5 OFF ON ON OFF 6 OFF ON ON ON 7 ON OFF OFF OFF 8 ON OFF OFF ON 9 ON OFF ON OFF 10 ON OFF ON ON 11 ON ON OFF OFF 12 ON ON OFF ON 13 ON ON ON OFF 14 ON ON ON ON 15
Resumen del contenido incluido en la página 17
NTI UNIMUX SERIES USB KVM SWITCH Command Protocol RS232 commands supported by the unit are defined below. All command strings should be terminated with a (carriage return). When a command is sent, the entire string is echoed back along with a response from the addressed unit as shown in the command definitions. All characters in the command string should be upper case, and all numbers below 10 should have a leading 0 (ex: 1 = 01). As command strings are sent, the inner chara
Resumen del contenido incluido en la página 18
NTI UNIMUX SERIES USB KVM SWITCH NTI Switch Control Program For Windows 9X, NT, 2000, XP, And Vista The NTI Switch Control Program is an easy and powerful graphical program that controls NTI switches through an RS232 interface. The NTI Switch Control Program is included on the CD packaged with the UNIMUX. The NTI Switch Control Program is downloaded by clicking on the link "Download NTI Switch Control Program". To install the NTI Switch Control Program after downloading 1.
Resumen del contenido incluido en la página 19
NTI UNIMUX SERIES USB KVM SWITCH 8) Change Volume for Audio Output/User (not applicable to this model) - change Audio port output volume 9) Read Connection for Output/User - read what input is connected to the specified output a) Read Connection for Audio Output/User (not applicable to this model) - read what input is connected to the specified output b) Read Mute Status and Volume for Audio Output/User (not applicable to this model) - read the volume and the mute stat
Resumen del contenido incluido en la página 20
NTI UNIMUX SERIES USB KVM SWITCH KEYBOARD FEATURES The keyboard configuration of each CPU is saved in the UNIMUX. For example, if the CPU attached to Port 2 had CAPS LOCK and NUM LOCK selected the last time that CPU was accessed, then they will automatically be set when that CPU is accessed again. (See Fig. 14 on page 18 for reference.) Keyboard-To-Computer Translation The UNIMUX enables a mixture of otherwise incompatible peripheral computer components to be connected tog