Resumen del contenido incluido en la página 1
User’s Manual
SCP/AAP A, SCP 200, SCP 250
Control Pads for Use With System Switchers
Extron Electronics, USA Extron Electronics, Europe Extron Electronics, Asia Extron Electronics, Japan
1230 South Lewis Street Beeldschermweg 6C 135 Joo Seng Road, #04-01 Daisan DMJ Building 6F
Anaheim, CA 92805 3821 AH Amersfoort PM Industrial Building 3-9-1 Kudan Minami
68-511-01
USA The Netherlands Singapore 368363 Chiyoda-ku, Tokyo 102-0074 Japan
714.491.1500 +31.33.453.4040 +65.6383.4400 +81.3.3511.7655
Resumen del contenido incluido en la página 2
Precautions Safety Instructions • English Warning FCC Class A Notice Power sources This equipment should be operated only from the power source This symbol is intended to alert the user of important indicated on the product. This equipment is intended to be used with a main operating and maintenance (servicing) instructions power system with a grounded (neutral) conductor. The third (grounding) pin is Note: This equipment has been tested and found to comply with the limits for a in the litera
Resumen del contenido incluido en la página 3
Table of Contents Chapter 1 • Introduction .......................................................... 1-1 About the SCP/AAP A, SCP 200, and SCP 250 .......... 1-2 Features ...................................................................................... 1-2 SCP 200 and SCP 250 feature ................................................ 1-2 Chapter 2 Installation and Operation ......................... 2-1 Installation Overview .......................................................... 2-2 Pr
Resumen del contenido incluido en la página 4
Table of Contents, cont’d SCP/AAP A, SCP 200, SCP 250 All trademarks mentioned in this manual are the properties of their respective owners. 68-511-01 Rev. B Printed in the USA 02 02 Chapter One 1 Introduction About the SCP/AAP A, SCP 200, and SCP 250 Features SCP/AAP A, SCP 200, SCP 250 Table of Contents ii
Resumen del contenido incluido en la página 5
Intr Introduction, cont’d oduction About the SCP/AAP A, SCP 200, and SCP 250 SCP/AAP A, SCP 200, SCP 250 The Extron SCP/AAP A, SCP 200, and SCP 250 are hardwired remote control keypads designed for use with Extron system switchers. Refer to the appropriate switcher’s user’s manual for information on installing, operating, and setting up the switcher. The system switcher cannot be configured from any of the SCP control pads. All switcher setup must be done from the switcher’s front panel or via
Resumen del contenido incluido en la página 6
Installation and Operation, cont’d Installation and Operation electrical wall box to allow room for the raised areas Installation Overview surrounding the knockouts. To install and set up an SCP control pad, follow these steps: 1. Cut out the center portion of the template. Cut up to the Turn the equipment off. Make sure that the SCP and the 1 dashed line if using an electrical box, or cut up to the system switcher are disconnected from the power source. dotted line if an electrical box will n
Resumen del contenido incluido en la página 7
12 3 4 56 7 8 Installation and Operation, cont’d If this SCP is at the end of a daisy chain of SCPs, do not use the Rear Panel Connectors 1 2 other connector. If this SCP is in the middle of a chain of SCPs, and Switches plug one end of a Comm-Link cable into the second captive screw connector, and plug the other end into the next SCP further away from the switcher. 11 J2 J1 3 DIP switches — Set these switches to indicate what model of system switcher the SCP is attached to. For the SCP/AAP A,
Resumen del contenido incluido en la página 8
Installation and Operation, cont’d 3. Plug one end of the cable into one of the SCP’s Cabling communications connectors, and plug the other end into For each SCP to be connected to a system switcher, set the rear the switcher (System 5cr Plus or System 7SC). panel DIP switches, then follow these steps: 4. If you are using a System 7SC switcher, cut a cable and 1. If it hasn’t already been done when the wall box was attach connectors to it for each additional SCP that will be installed, cut a len
Resumen del contenido incluido en la página 9
Installation and Operation, cont’d 6. Another device such as an interface or distribution Plus AUDIO PC1 INPUT IR DISPLAY ROOM AUDIO COMPUTER POWER MUTE MODE PC1 PC2 INPUT3 VID1 VID2 amplifier can receive power from the system switcher via VID MAX. TX RX LEARN Y/C VID VID CLIP CONFIG PC Y/C Y/C MIN. VOLUME RETRY an SCP, as long as the following limits for the total load attached to each switcher are not exceeded: System 5cr Plus System 7SC — 12VDC, 1 A Aux 1 Aux 2 System 5cr Plus — 12VDC, 0.
Resumen del contenido incluido en la página 10
Installation and Operation, cont’d Mode button — For the System 5cr Plus, this button can be Front Panel Features and Operation programmed to switch the mode of the projector between 2 4 5 6 2 3 4 computer-video (RGB), S-video, and composite video. For the System 7SC, this button can be programmed to execute any RS-232 or IR command. IR 3 Volume control knob and LED — Turn this knob to adjust the DISPLAY AUDIO POWER MUTE MAX/ MODE audio volume. For the System 7SC this affects the Variable IR
Resumen del contenido incluido en la página 11
Installation and Operation, cont’d Testing/Troubleshooting Mounting the SCP to the Electrical Box Before installing the control pad into the wall or furniture, test Once the system has been cabled and tested, the control pad can the system to make sure that the connections are correct and the be installed in the wall or furniture. SCP is working correctly. 1. With power removed, insert the SCP into the wall or 1. Connect the cables between the switcher and the SCP(s). furniture. 2. Power on the
Resumen del contenido incluido en la página 12
Installation and Operation, cont’d SCP/AAP A, SCP 200, SCP 250 Appendix A A Specifications, Part Numbers, and Accessories Specifications Included Parts Accessories Cables SCP/AAP A, SCP 200, SCP 250 Installation and Operation 2-14
Resumen del contenido incluido en la página 13
Specifications, Accessories, Part Numbers, cont’d Specifications Product weight Control/remote — control pads SCP/AAP A ...................... 0.2 lbs (0.1 kg) IR controller module ................... IR 701 (optional) SCP 200 .............................. 0.3 lbs (0.1 kg) General SCP 250 .............................. 0.5 lbs (0.2 kg) Power ............................................. 12VDC, at 60 mA, from the System 7SC or Shipping weight System 5cr Plus switcher SCP/AAP A ..................
Resumen del contenido incluido en la página 14
Specifications, Accessories, Part Numbers, cont’d Included Parts SCP/AAP A, SCP 200, SCP 250 These items are included in each order for an SCP control pad: Included parts (SCP/AAP A) Part number SCP/AAP A (gray, black, white) 60-339-01, -02, -03 3.5 mm, 5-pole captive screw connectors 10-319-10 Included parts (SCP 200) Part number SCP 200 (gray, black, white) 60-338-01, -02, -03 2-gang electrical box 3.5 mm, 5-pole captive screw connectors 10-319-10 Included parts (SCP 250) Part number SCP 250 (
Resumen del contenido incluido en la página 15
0.000 0.424 0.794 1.094 1.388 1.394 1.994 2.294 2.594 3.194 3.200 3.494 3.794 4.164 4.588 Dimensions, Templates, and Labels, cont’d SCP 200 dimensions Panel Dimensions The following diagrams have been reduced to fit on the pages. All dimensions are given in inches. The symbol “ø“ indicates a diameter. SCP/AAP A dimensions 2.500 .371 .185 .150 .150 .166 .331 2.084 DETAIL A #440 X 3.75 STUD (4 REQ'D). INSTALL FROM NEAR SIDE. + .000 ø 0.160 MAX. – .010 EXTRUSION AROUND STUD ON FAR SIDE.
Resumen del contenido incluido en la página 16
0.000 0.785 0.785 1.373 1.373 1.385 1.385 1.985 1.985 2.585 2.585 3.085 3.185 3.785 4.385 4.685 4.985 4.997 5.585 6.385 Dimensions, Templates, and Labels, cont’d SCP 250 dimensions SCP 250 dimensions details SCP/AAP A, SCP 200, SCP 250 Dimensions, Templates, Labels B-4 SCP/AAP A, SCP 200, SCP 250 Dimensions, Templates, Labels B-5 0.06" RADIUS AROUND THE TOP OF THIS EDGE. 4.500 3.891 DISPLAY AUDIO POWER MUTE MAX/ MODE 2.950 MIN IR 2.850 2.600 VOLUME DETAIL A 1.950 DETAIL B 1.400 1.050 0.609
Resumen del contenido incluido en la página 17
Dimensions, Templates, and Labels, cont’d SCP 200 template Templates This full-size template is a guide for cutting a hole for the Use the templates as a guide to mark and cut the hole in the wall 2-gang size electrical box for the SCP 200 or for the SCP 200 or furniture through which the SCP control pad will be installed. itself (if it will be installed directly into furniture or wall). The templates include the recommended 0.1” (0.25 cm) clearance on all sides of the electrical wall box to all
Resumen del contenido incluido en la página 18
Dimensions, Templates, and Labels, cont’d SCP 250 template Labeling Buttons on the SCPs This full-size template is a guide for cutting a hole for the The SCP 200 and SCP 250 have translucent panels (“windows”) 3-gang size electrical box for the SCP 250 or for the SCP 250 behind which customized labels can be inserted. To remove a itself (if it will be installed directly into furniture or wall). panel, 1. Insert the head of a small Phillips screwdriver into the hole in one end of the panel. 2. G
Resumen del contenido incluido en la página 19
Dimensions, Templates, and Labels, cont’d 4. Cut the label strips to the appropriate length, and install Label templates them in the SCP’s windows. Below and on the following pages are full-sized templates for For information about using the program, you can access a help the labels. Feel free to photocopy them, write button file by clicking on the Help menu on the main screen and information in each area of the blank templates as desired, cut choosing Show Help. the strips out, and insert the
Resumen del contenido incluido en la página 20
Dimensions, Templates, and Labels, cont’d SCP 250 labels This page is left intentionally blank. SCP/AAP A, SCP 200, SCP 250 Dimensions, Templates, Labels B-12 SCP/AAP A, SCP 200, SCP 250 Dimensions, Templates, Labels B-13 For use with a System 7SC switcher ROOM 1 ROOM 2 123 4 56 7 For use with a System 5cr Plus switcher ROOM 15 234 n/a n/a n/a