Resumen del contenido incluido en la página 1
2E48-27R/2E49-27R
SmartSwitch 2200
User’s Guide
RX RX TX RX RX RX RX RX TX
RX TX TX TX TX TX TX
PWR
17 18 19 20 21 22 23 24
RESET
COM CPU
RX TX RX TX RX TX RX TX RX TX RX TX RX TX RX TX
9 10 11 12 13 14 15 16
RX TX RX TX RX TX RX TX RX TX RX TX RX TX RX TX
1 2 3 4 5 6 7 8
2E48-27R 25 26
TX RX TX RX TX RX TX RX TX RX TX RX TX RX TX
RX
PWR 24
17 18 19 20 21 22 23
RESET
CPU
COM
RX TX RX TX RX TX RX TX RX TX RX TX RX TX RX TX
9 10 11 12 13 14 15 16
RX TX RX TX RX TX RX TX RX TX RX TX RX TX RX TX
Resumen del contenido incluido en la página 2
Resumen del contenido incluido en la página 3
Only qualified personnel should perform installation procedures. NOTICE Cabletron Systems reserves the right to make changes in specifications and other information contained in this document without prior notice. The reader should in all cases consult Cabletron Systems to determine whether any such changes have been made. The hardware, firmware, or software described in this manual is subject to change without notice. IN NO EVENT SHALL CABLETRON SYSTEMS BE LIABLE F
Resumen del contenido incluido en la página 4
Notice INDUSTRY CANADA NOTICE This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications. Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la class A prescrites dans le Règlement sur le brouillage radioélectrique édicté par le ministère des Communications du Canada
Resumen del contenido incluido en la página 5
Notice EXCLUSION OF WARRANTY AND DISCLAIMER OF LIABILITY 1. EXCLUSION OF WARRANTY. Except as may be specifically provided by Cabletron in writing, Cabletron makes no warranty, expressed or implied, concerning the Program (including its documentation and media). CABLETRON DISCLAIMS ALL WARRANTIES, OTHER THAN THOSE SUPPLIED TO YOU BY CABLETRON IN WRITING, EITHER EXPRESSED OR IMPLIED, INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
Resumen del contenido incluido en la página 6
Notice SAFETY INFORMATION CLASS 1 LASER TRANSCEIVERS THE FE-100F3 FAST ETHERNET INTERFACE MODULE, FPIM-05 AND FPIM-07 FDDI PORT INTERFACE MODULES, AND APIM-29 ATM PORT INTERFACE MODULE USE CLASS 1 LASER TRANSCEIVERS. READ THE FOLLOWING SAFETY INFORMATION BEFORE INSTALLING OR OPERATING THESE MODULES. The Class 1 laser transceivers use an optical feedback loop to maintain Class 1 operation limits. This control loop eliminates the need for maintenance checks or adjustments. The
Resumen del contenido incluido en la página 7
Notice DECLARATION OF CONFORMITY Application of Council Directive(s): 89/336/EEC 73/23/EEC Manufacturer’s Name: Cabletron Systems, Inc. Manufacturer’s Address: 35 Industrial Way PO Box 5005 Rochester, NH 03867 European Representative Name: Mr. J. Solari European Representative Address: Cabletron Systems Limited Nexus House, Newbury Business Park London Road, Newbury Berkshire RG13 2PZ, England Conformance to Directive(s)/Product Standards: EC Directive 89/336/EEC EC Dir
Resumen del contenido incluido en la página 8
Notice vi 2E48-27R/2E49-27R User’s Guide
Resumen del contenido incluido en la página 9
CONTENTS CHAPTER 1 INTRODUCTION 1.1 Using This Guide......................................................................... 1-1 1.2 Structure of This Guide................................................................ 1-1 1.3 2E4X-27R Overview.................................................................... 1-2 1.3.1 Connectivity .................................................................... 1-4 1.3.2 Full Duplex Switched Ethernet........................................ 1-
Resumen del contenido incluido en la página 10
Contents CHAPTER 4 TROUBLESHOOTING 4.1 Using LANVIEW...........................................................................4-1 4.2 FE-100TX LED.............................................................................4-4 4.3 Troubleshooting Checklist............................................................4-6 4.4 Using the RESET Button .............................................................4-7 CHAPTER 5 LOCAL MANAGEMENT 5.1 Overview .........................................
Resumen del contenido incluido en la página 11
Contents 5.11 Ethernet Full Duplex Configuration Screen ............................... 5-42 5.11.1 Setting the Operation Mode.......................................... 5-44 5.12 Device Specific Configuration Menu Screen ............................. 5-45 5.13 System Resources Screen........................................................ 5-47 5.13.1 Setting the Reset Peak Switch Utilization..................... 5-48 5.14 High Speed Interface Configuration Menu Screen.................... 5-
Resumen del contenido incluido en la página 12
Contents APPENDIX B FE-100TX, FE-100FX, AND FE-100F3 SPECIFICATIONS B.1 FE-100TX.................................................................................... B-1 B.1.1 Auto-Negotiation............................................................. B-2 B.2 FE-100FX.................................................................................... B-3 B.3 FE-100F3 .................................................................................... B-4 APPENDIX C OPTIONAL INSTALLATION
Resumen del contenido incluido en la página 13
CHAPTER 1 INTRODUCTION Welcome to the 2E48-27R/2E49-27R SmartSwitch 2200 User’s Guide. This guide describes the 2E48-27R and 2E49-27R SmartSwitch 2200 devices and provides information concerning network requirements, installation, troubleshooting, and the use of Local Management. 1.1 USING THIS GUIDE Read through this guide completely to understand the 2E48-27R and 2E49-27R features, capabilities, and Local Management functions. A general working knowledge of Ethernet
Resumen del contenido incluido en la página 14
Chapter 1: Introduction Appendix A, Specifications, contains information on functionality and operating specifications, connector pinouts, environmental requirements, and physical properties. Appendix B, FE-100TX, FE-100FX, and FE-100F3 Specifications, contains information about FE-100TX pinouts and information concerning cable types used with the FE-100FX and FE-100F3. Appendix C, Optional Installations and Mode Switch Bank Settings, describes how to install optional Fast Ether
Resumen del contenido incluido en la página 15
2E4X-27R Overview RESET Button Port Status LEDs Optional HSIM Slot RX TX RX TX RX TX RX TX RX TX RX TX RX TX RX TX PWR 17 18 19 20 21 22 23 24 RESET CPU COM RX TX RX TX RX TX RX TX RX TX RX TX RX TX RX TX 9 10 11 12 13 14 15 16 RX TX RX RX RX TX RX TX TX RX TX TX RX TX RX TX 1 2 3 4 5 6 7 8 2E48-27R 25 26 Network Ports 1 - 24 System LEDs (ST connectors), Optional Fast Ethernet Interface COM Port Supports Module Ports 25 and 26 Multimode Fiber Optics 2E48-27R RESET Button Port Status LEDs Opt
Resumen del contenido incluido en la página 16
Chapter 1: Introduction 1.3.1 Connectivity The 2E48-27R connects to Ethernet networks or workstations through 24 ST fiber optic ports on the front panel. These ports support multimode fiber optic cables at lengths up to 2 kilometers. The ports are IEEE 802.3 10BASE-F compliant. The 2E49-27R connects to Ethernet networks or workstations through 24 ST fiber optic ports on the front panel. These ports support single mode fiber optic cables at lengths up to 5 kilometers. The ports a
Resumen del contenido incluido en la página 17
2E4X-27R Overview For more information about SmartTrunk, refer to the Cabletron Systems SmartTrunk User’s Guide. 1.3.4 Runtime IP Address Discovery This feature enables the 2E4X-27R to automatically accept an IP address from a Boot Strap Protocol (BootP) server on the network into NVRAM without requiring a user to enter an IP address through Local Management. When the 2E4X-27R is connected to the network and powered up, Runtime IP Address Discovery (RAD) checks the 2E4X-27R for an
Resumen del contenido incluido en la página 18
Chapter 1: Introduction 1.3.6 Switching Options The 2E4X-27R provides IEEE 802.1D switching, IEEE 802.1Q switching, or SecureFast Switching Virtual Network Services between all of the front panel interfaces including Fast Ethernet Interface Modules and High Speed Interface Modules (HSIMs). 802.1Q switching and SecureFast switching allow for future migration to Virtual Network technologies without requiring the replacement of existing equipment. 1.3.7 Standards Compatibility The
Resumen del contenido incluido en la página 19
2E4X-27R Overview 1.3.10 Optional Features Options for the 2E4X-27R are Fast Ethernet Interface Modules and High Speed Interface Modules, which add remote uplink capability. Cabletron Systems provides Fast Ethernet Interface Modules to support uplinks to 100 Mbps Ethernet backbones or high speed connections to local servers. Table 1-1 provides a list of the Fast Ethernet Interface Modules. . Table 1-1 Fast Ethernet Interface Modules P/N Description Application Supports Category 5 Uns
Resumen del contenido incluido en la página 20
Chapter 1: Introduction 1.4 DOCUMENT CONVENTIONS The following conventions are used throughout this document: Note symbol. Calls the reader’s attention to any item of NOTE information that may be of special importance. Tip symbol. Conveys helpful hints concerning procedures or TIP actions. Caution symbol. Contains information essential to avoid damage to the equipment. ! CAUTION Electrical Hazard Warning symbol. Warns against an action that could result in personal injury or