Copyright © 2005-2008, Hangzhou H3C Technologies Co., Ltd. All Rights Reserved No part of this manual may be reproduced or transmitted in any form or by any means without prior written consent of Hangzhou H3C Technologies Co., Ltd. Trademarks 3 H3C, , Aolynk, , H Care, , TOP G, , IRF, NetPilot, Neocean, NeoVTL, SecPro, SecPoint, SecEngine, SecPath, 2 n Comware, Secware, Storware, NQA, VVG, V G, V G, PSPT, XGbus, N-Bus, TiGem, InnoVision and HUASAN are trademarks of Hangzhou H3C Tec
Resumen del contenido incluido en la página 3
Technical Support soho@h3c.com http://www.h3c.com
Resumen del contenido incluido en la página 4
About This Manual Purpose This document is used to guide you through installing this product. Please read it carefully before your operation. Intended Audience This document is intended for network administrators who know well of the basic network knowledge and network terms. Organization This document is organized as follows: Chapter Content This chapter describes the appearance of 1 Product Overview the H3C S1526 Smart Ethernet Switch (hereinafter referred to as the S1526). This
Resumen del contenido incluido en la página 5
Chapter Content 5 Appendix – Port This chapter describes the port properties, Properties such as the connector type and quantity. Conventions The manual uses the following conventions: I. Symbols Convention Description Means reader be careful. Improper operation may cause data loss or damage Caution to equipment. Note Means a complementary description. Environmental Protection This product has been designed to comply with the requirements on environmental protection.
Resumen del contenido incluido en la página 6
Installation Manual H3C S1526 Smart Ethernet Switch Table of Contents Table of Contents Chapter 1 Product Overview ........................................................1-1 1.1 Introduction ........................................................................1-1 1.2 Appearance........................................................................1-2 1.2.1 Front Panel..............................................................1-2 1.2.2 Rear Panel...................................
Resumen del contenido incluido en la página 7
Installation Manual H3C S1526 Smart Ethernet Switch Table of Contents Chapter 4 Appendix – Technical Specifications ........................4-1 Chapter 5 Appendix – Port Properties.........................................5-1 5.1 Properties of 10/100Base-TX Ethernet Ports ....................5-1 5.2 Properties of 1000 Mbps Ethernet Ports............................5-2 5.3 Properties of SFP Module Ports ........................................5-2 5.4 Properties of Console Port.............
Resumen del contenido incluido en la página 8
Installation Manual H3C S1526 Smart Ethernet Switch Chapter 1 Product Overview Chapter 1 Product Overview 1.1 Introduction H3C S1526 Smart Ethernet Switch (hereinafter referred to as the S1526) is suitable for the networking of small and medium-sized enterprises, and Internet cafe. It provides one console port, 24 × 10/100Base-TX autosensing Ethernet ports and two 1000 Mbps uplink combo ports. Note: Port 25 and port 26 are 1000 Mbps uplink combo ports. Each combo port suppor
Resumen del contenido incluido en la página 9
Installation Manual H3C S1526 Smart Ethernet Switch Chapter 1 Product Overview 1.2 Appearance 1.2.1 Front Panel As shown in Figure 1-1, the S1526 has on its front panel from the left to the right: Power LED, 10/100Base-TX port LEDs, 10/100Base-TX ports, 1000 Mbps uplink combo ports and LEDs, and Console port. Figure 1-1 Front panel The following table presents descriptions of the LEDs on the front panel. Table 1-1 LED descriptions LED Status Description Green The switch is pow
Resumen del contenido incluido en la página 10
Installation Manual H3C S1526 Smart Ethernet Switch Chapter 1 Product Overview LED Status Description Green A link is established. Link/Act OFF No link is established. Blinking Data is being transmitted or received. 1.2.2 Rear Panel The S1526 has one AC power socket on its rear panel, as shown in Figure 1-2. Figure 1-2 Rear panel 1-3
Resumen del contenido incluido en la página 11
Installation Manual H3C S1526 Smart Ethernet Switch Chapter 2 Installation Chapter 2 Installation 2.1 Precautions To avoid any damage to the device or human body arising from improper use of the S1526, please follow the precautions and requirements listed below. I. Safety precautions Unplug the switch before cleaning. Do not clean the switch with wet cloth or liquid. Do not place the switch near water or in any damp area. Keep water or moisture from entering the switch chassis.
Resumen del contenido incluido en la página 12
Installation Manual H3C S1526 Smart Ethernet Switch Chapter 2 Installation Do not open the chassis while the switch is in operation. Do not open the chassis if not necessary, even when the switch is not powered on. II. Installation Environment Requirements The S1526 can be installed in a corridor or a room. The following requirements must be met wherever it is installed in a rack or on a workbench. There is adequate space (more than 10 cm (0.33 in.)) near the ventilation hole of th
Resumen del contenido incluido en la página 13
Installation Manual H3C S1526 Smart Ethernet Switch Chapter 2 Installation Electromagnetic shielding approach is adopted when necessary, such as using shielded port cable. All port cables are wired indoor, to prevent the ports from any damage that may be caused by overvoltage and overcurrent from lightning strike. 2.2 Installing the Switch Caution: There is a seal on one mounting screw on the chassis of the switch. This seal must remain intact unless the agent is on the spot t
Resumen del contenido incluido en la página 14
Installation Manual H3C S1526 Smart Ethernet Switch Chapter 2 Installation Figure 2-1 Fix the mounting ears 3) Put the switch in a rack tray. Slide the switch along the guide rails to an appropriate place. 4) Fix the mounting ears to the rack posts with screws at both sides. Make sure the switch is securely fixed to the rack tray. Figure 2-2 Installing the switch in a rack 2-4
Resumen del contenido incluido en la página 15
Installation Manual H3C S1526 Smart Ethernet Switch Chapter 2 Installation Note: The mounting brackets are used for fixing rather than weight bearing. In a 19-inch standard rack, the weight of the switch is supported by the tray beneath it. 2.2.2 Installing the Switch on a Workbench In circumstances that a 19-inch standard rack is not available, you can mount the switch on a clean workbench. You are recommended to fasten the feet to the switch before installation. Take the follo
Resumen del contenido incluido en la página 16
Installation Manual H3C S1526 Smart Ethernet Switch Chapter 2 Installation 2.3 Connecting the Cables 2.3.1 Connecting Devices to the Switch I. Connect the device to the Ethernet port Use either crossover cables or straight through cables to connect the PC(s) or other device(s) to the Ethernet ports on the switch. II. Connect the device to the uplink port If the 10/100/1000Base-T Ethernet port is to be used as the uplink port, connect the device to it with either a crossover cable
Resumen del contenido incluido en la página 17
Installation Manual H3C S1526 Smart Ethernet Switch Chapter 2 Installation Caution: To avoid eye damages, do not look directly at the laser beam inside the optical fiber. 2.3.2 Connecting the Console Cable Figure 2-5 Connecting the switch to a terminal through console port The switch can be configured through a terminal. Take the following steps to connect the switch and terminal through a console cable. 1) Plug the DB-9 connector of the console cable into the serial port of
Resumen del contenido incluido en la página 18
Installation Manual H3C S1526 Smart Ethernet Switch Chapter 2 Installation Caution: Because the PC serial port is not hot-swappable, DO NOT plug the cable connector into or unplug it from the PC serial port when the switch is powered on. In connecting the PC to the switch plug the DB-9 connector of the console cable to the PC port first, and then plug the RJ-45 connector to the switch port. In disconnecting unplug the RJ-45 connector first and then the DB-9 connector. 2.3.3 Conne
Resumen del contenido incluido en la página 19
Installation Manual H3C S1526 Smart Ethernet Switch Chapter 2 Installation 2.4 Starting Up the Switch 2.4.1 Configuring Terminal Parameters 1) Start the PC. In the Windows operating system, click [Start/Programs/Accessories/Communications] to run the Hyper Terminal program on the PC. 2) Set the serial port parameters, as follows (taking the Hyper Terminal in Windows XP for example): Bits per second (baud rate): 9600 bps Data bits: 8 Stop bits: 1 Parity: None Flow control: N
Resumen del contenido incluido en la página 20
Installation Manual H3C S1526 Smart Ethernet Switch Chapter 2 Installation MAIN MENU 1. Modify password 2. Set IP address/Subnet mask/Gateway 3. Reset to default configuration 4. Save current configuration 5. Modify management VLAN 0. Reboot Enter your choice (0-5): Select one option and enter its number after the “Enter your choice (0-5):” to perform the configuration. Table 2-1 Menu item description No. Description 1 Modify the Web NMS password for the switch Set