Resumen del contenido incluido en la página 1
Touchmonitor User Guide
1928L 19” LCD Desktop Touchmonitor
5000 Series
Resumen del contenido incluido en la página 2
User Guide 1928L 19” LCD Desktop Touchmonitor Revision C P/N E116103
Resumen del contenido incluido en la página 3
Copyright © 2007 Tyco Electronics Corporation. All Rights Reserved. No part of this publication may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language or computer language, in any form or by any means, including, but not limited to, electronic, magnetic, optical, chemical, manual, or otherwise with- out prior written permission of Elo TouchSystems. Disclaimer The information in this document is subject to change without notice.
Resumen del contenido incluido en la página 4
Warnings and Cautions Warning ! • Danger - Explosion hazard. Do not use in the presence of flammable anesthetics, and other flammable materials. • To prevent fire or shock hazards, do not immerse the unit in water or expose it to rain or moisture. • Do not use the unit with an extension cord receptacle or other outlets unless the prongs of the power cord can be fully inserted. • RISK OF ELECTRICAL SHOCK - DO NOT OPEN. To reduce the risk of electrical shock, DO NOT remove the back of the equipmen
Resumen del contenido incluido en la página 5
Caution • Power cord is used as a disconnection device. To de-energize equipment, disconnect the power cord. • This unit must follow the national requirement and local state laws to dispose unit. • Before connecting the cables to your Elo touchmonitor, make sure all components are powered OFF. Only approved components complying with IEC60601-1 series can be connected to ET1928L in Patient Environment. The use of ACCESSORY equipment not complying with the equivalent safety requirements of this eq
Resumen del contenido incluido en la página 6
CAUTION-Life Support ! Care must be taken when this touchmonitor is a critical component of a life support system or device. In case of failure of this touchmonitor, appropriate redundant systems should be incorporated into the system or device to prevent injury to the user or patient. The following should be an integral part of the safety design of a life support system or device using this touchmonitor for a critical function. • An alternate interface or fail-safe must be available should the
Resumen del contenido incluido en la página 7
Classification With respect to electrical shock, fire in accordance with UL60601-1 and CAN/CSA C22.2 No. 60601-1 This monitor is a Class I (GROUNDED) DEVICE. These displays are classified NO APPLIED PARTS EQUIPMENT. Protection against harmful ingress of water: INGRESS PROTECTION (IPX1) This monitor shall be classified as ORDINARY EQUIPMENT, not intended or evaluated for use in the presence of flammable anesthetic mixture with air, oxygen, or nitrous oxide. Mode of Operation: CONTINUOUS OPERATI
Resumen del contenido incluido en la página 8
European Standards and Classifications Standards: EN 60601-1-2: 2001 The EMC limits and test methods are referred to the following standards: Emission: Immunity CISPR 11: 2003+A1:2004 IEC 61000-4-2: 2001 AS/NZS CISPR 11:2004 IEC 61000-4-3: 2002+A1:2002 (Group 1, Class B) IEC 61000-4-4: 2004 IEC 61000-4-5: 2001 EN55011: 1998+A1: 1999+ IEC 61000-4-6: 2003+A1:2004 A2: 2002, (Group 1, Class B) IEC 61000-4-8: 2001 IEC 61000-4-11: 2004 IEC 61000-3-2: 2000, (Refer to note * below) IEC 61000-3-3; 1995+A
Resumen del contenido incluido en la página 9
Guidance and manufacturer’s declaration-electromagnetic immunity- for all EQUIPMENT AND SYSTEMS Guidance and manufacturer’s declaration-electromagnetic emissions The ET1928L is intended for use in the electromagnetic environment specified below. The customer or the user of the ET1928L should assure that it is used in such an environment. Emissions test Compliance Electromagnetic environment-guidelines RF emissions Group 1 The ET1928L uses RF energy only for its internal CISPR 11
Resumen del contenido incluido en la página 10
Guidance and manufacturer’s declaration-electromagnetic immunity- for all EQUIPMENT AND SYSTEMS Guidance and manufacturer’s declaration-electromagnetic immunity The ET1928L is intended for use in the electromagnetic environment specified below. The customer or the user of the ET1928L should assure that it is used in such an environment. Immunity test IEC 60601 Compliance level Electromagnetic environment- test level guidelines Electrostatic ± 6 kV contact ± 6 kV c
Resumen del contenido incluido en la página 11
Guidance and manufacturer’s declaration-electromagnetic immunity- for all EQUIPMENT AND SYSTEMS that are not LIFE-SUPPORTING Guidance and manufacturer’s declaration-electromagnetic immunity The ET1928L is intended for use in the electromagnetic environment specified below. The user of the ET1928L should assure that it is used in such an environment. Immunity test IEC 60601 test level Compliance Electromagnetic environment-guidelines level Portable and mobile RF communicat
Resumen del contenido incluido en la página 12
Recommended separation distance between portable and mobile RF communications equipment and the ET1928L for all EQUIPMENT AND SYSTEMS that are not LIFE-SUPPORTING Recommended separation distances between portable and mobile RF communications equipment and the ET1928L The ET1928L is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of the ET1928L can help prevent electromagnetic interference by
Resumen del contenido incluido en la página 13
Table of Contents Warnings and Cautions................................................. iv Power Display & Power Saving ............................17 Warning ................................................................. iv General Power Saving Mode ........................17 Caution ................................................................... v Display Angle .................................................17 Caution-Life Support .....................................................
Resumen del contenido incluido en la página 14
Resumen del contenido incluido en la página 15
C H A P T E R 1 INTRODUCTION Product Description The 1928L is a medical display designed to present information to the operator and the customer. The 1928L is available in serial and USB(combo) touch interface as well as non-touch. The 1928L functionally consists of a 19” LCD main display with a touchscreen. The main display element is a 19” diagonal SXGA resolution (1280 x 1024) LCD display. The display consists of an LCD display and touchscreen. The 1928L is powered by 12 VDC from an extern
Resumen del contenido incluido en la página 16
LCD Display Performance Features 19” TFT LCD Display Panel Display format 1280 x 1024 Display area 376.32 mm (H) x 301.056 mm (V) Pixel pitch 0.294 mm (H) x 0.294 mm (V) Contrast Ratio 1300:1( typical) Brightness 2 LCD 300 cd/m (typical) 2 AccuTouch 246 cd/m (typical) 2 IntelliTouch 276 cd/m (typical) Accutouch transmission 82% (typical) Intellitouch transmission 92% (typical) Response time Tr = 15 msec / Tf = 5 msec typical; 12 ms gray to gray response Display color 16.7 million colors Typical
Resumen del contenido incluido en la página 17
C H A P T E R 2 INSTALLATION AND SETUP This chapter discusses how to install your LCD touchmonitor and how to install Elo TouchSystems driver software. Unpacking Your Touchmonitor Check that the following items are present and in good condition: LCD monitor VGA cable USB cable Serial Cable European power cable Power cable US/Canada Elo QuickStar t CD Software DVI Cable CD and Quick Install Guide Power adaptor 2-3
Resumen del contenido incluido en la página 18
Product Overview Main Unit Back Unit Side View 2-4 Elo Touchmonitor User Guide
Resumen del contenido incluido en la página 19
Base Bottom View TM Kensington Lock TM The Kensington lock is a security device that prevents theft. To find out more about this secu- rity device, go to http://www.kensington.com. 2-5
Resumen del contenido incluido en la página 20
Touch Interface Connection Note: Before connecting the cables to your touchmonitor and PC, be sure that the computer and touchmonitor are turned off. STEP 1-Connecting the Video Cable CONNECTIONS ON UNDERSIDE VIDEO PORT FEMALE 15-PIN VIDEO CONNECTOR VIDEO CABLE • Tilt the screen up and back to access the connection ports. • Connect the 15-pin video cable (the ferrite bead end) or 24-pin DVI-D cable to the video port on your PC. • Connect the other end of the video cable to the video connector