Resumen del contenido incluido en la página 1
User’s Manual
MTP R 15HD RSA D
MTP 15HD Decora Receiver
Extron USA - West Extron USA - East Extron EMEA Extron Asia Extron Japan Extron China Extron Middle East
Headquarters
+800.633.9876 +800.3987.6673 +800.7339.8766 +81.3.3511.7655 +400.883.1568 +971.4.2991800 68-1463-01 Rev. A
+800.633.9876 Inside USA / Canada Only Inside Europe Only Inside Asia Only +81.3.3511.7656 FAX Inside China Only +971.4.2991880 FAX
Inside USA / Canada Only 09 08
+1.919.863.1794 +31.33.453.4040 +65.6383.4400 +86.21.37
Resumen del contenido incluido en la página 2
Precautions Safety Instructions � English Extron’s Warranty Warning Power sources � This equipment should be operated only from the power source This symbol is intended to alert the user of important indicated on the product. This equipment is intended to be used with a main power operating and maintenance (servicing) instructions in system with a grounded (neutral) conductor. The third (grounding) pin is a safety Extron Electronics warrants this product against defects in materials and wor
Resumen del contenido incluido en la página 3
警告 安全须知 • 中文 电源 • 该设备只能使用产品上标明的电源。 设备 这个符号提示用户该设备用户手册中 必须使用有地线的供电系统供电。 第三条线 有重要的操作和维护说明。 (地线)是安全设施,不能不用或跳过。 拔掉电源 • 为安全地从设备拔掉电源,请拔掉所有设备后 这个符号警告用户该设备机壳内有暴 或桌面电源的电源线,或任何接到市电系统的电源线。 电源线保护 • 妥善布线, 避免被踩踏,或重物挤压。 露的危险电压,有触电危险。 维护 • 所有维修必须由认证的维修人员进行。 设备内部没 注意 有用户可以更换的零件。为避免出现触电危险不要自己 阅读说明书 • 用户使用该设备前必须阅读并理 试图打开设备盖子维修该设备。 解所有安全和使用说明。 通风孔 • 有些设备机壳上有通风槽或孔,它们是用来防止 保存说明书 • 用户应保存安全说明书以备将来使 机内敏感元件过热。 不要用任何东西挡住通风孔。 用。 锂电池 • 不正确的更换电池会有爆炸的危险。 必须使用与 遵守警告 • 用户应遵守产品和用户指南上的所有安 厂家推荐的相同或相近型号的电池。 按照生产厂的建 全和操作说明。 议处理废弃电
Resumen del contenido incluido en la página 4
Table of Contents Chapter One • Introduction .................................................... 1-1 Chapter One • Introduction .................................................... 1-1 ® About the MTP 15HD Decora Receiver ............................. 1-2 RS-232 function ...................................................................... 1-3 Twisted Pair (TP) Cable Advantages .................................... 1-3 Transmission distance ..................................................
Resumen del contenido incluido en la página 5
Table of Contents, cont’d MTP R 15HD RSA D Chapter One 1 Introduction ® About the MTP 15HD Decora Receiver Twisted Pair (TP) Cable Advantages 68-1463-01 Rev. A 09 08 All trademarks mentioned in this manual are the properties of their respective owners. ii MTP R 15HD RSA D • Table of Contents
Resumen del contenido incluido en la página 6
Introduction ® RS-232 function About the MTP 15HD Decora Receiver The Extron MTP R 15HD RSA D is a mini twisted pair (MTP) When the audio/RS-232 portion of the TP link is RS-232, it is receiver, in a Decora form factor, that auto-detects between either unidirectional or bidirectional, selectable by a DIP switch. audio or RS-232 serial data on the audio/RS-232 wire pair. The By default, the RS-232 portion of the TP link is N receiver is compatible with the entire line of Extron MTP 15HD u
Resumen del contenido incluido en la página 7
Introduction, cont’d The MTP units are designed for and perform best with N MTP R 15HD RSA D Extron Enhanced Skew-Free A/V cable terminated in accordance with the TIA/EIA T 568 A wiring standard. CAT 5, 5e, and 6 cables are acceptable, but less preferable. We also recommend the use of preterminated and tested cables. Cables terminated on site should be tested before use to ensure that they comply with Category 5 specifications. Recommended transmission distances at 60 Hz Video Pre-Pea
Resumen del contenido incluido en la página 8
Installation Installation 2.50 (63.5 mm) The MTP R 15HD RSA D receiver can be installed in a one-gang electrical wall box with a Decora wall plate cover (supplied). The installation must conform to national and local electrical codes and to the wall plate’s size requirements. TP Pigtail UL/safety requirements The following Underwriters Laboratories (UL) requirements 1.50 (38.1 mm) pertain to the installation of the Decora receiver into a wall or furniture. 1. This unit must not be connecte
Resumen del contenido incluido en la página 9
Installation and Operation, cont’d 5. Secure the wall box with nails or screws, leaving the front 10. Connect a video and an RS-232 and/or audio device to the edge flush with the outer wall or furniture surface. See front panel (see "Front panel features", later in this chapter, figure 2-2. for connector details). 11. Restore the power supply, and test the transmitter/receiver Wall Stud Wall Stud system. Make any cabling adjustments before final Signal Signal installation, as the cables
Resumen del contenido incluido en la página 10
Installation and Operation, cont’d Vertical Sync switch (2) — Set this switch on (right) for positive Connections and Settings vertical sync or off (left) for negative sync. See figure 2-4 to identify the rear and front panel connections on the receiver. Most devices use negative sync. N Set the Composite Sync, SOG, and Video DIP switches N as shown in the table below for the various input and MTP 15HD RSA D Rx Rear Panel MTP 15HD RSA D Rx Front Panel output video formats. Composite Sy
Resumen del contenido incluido en la página 11
Installation and Operation, cont’d Front panel features Making Connections Output video connector — Connect a projector or other high d Power supply wiring resolution video device to this 15-pin HD connector. Figure 2-5 shows how to wire the power connector. Audio RS-232 output connector — Insert a 3.5 mm, 5-pole e captive screw connector into this jack for a mono audio and/or an RS-232 serial output. See "Audio/RS-232 cable termination", on page 2-12, to wire the connector for either or
Resumen del contenido incluido en la página 12
Installation and Operation, cont’d Use the supplied tie-wrap to strap the power cord to the extended tail of the connector. Alternatively, an optional Extron PS 123 Universal 12 VDC Power Supply, part #60-814-01, can power multiple Extron 12 VDC devices using only one AC power connector. TP cable termination RJ-45 termination with CAT 5, CAT 5e, or N CAT 6 cable must comply with the TIA/EIA T568A or TIA/EIA T568B wiring standards for all connections. RJ-45 termination with Skew-Free A/V U
Resumen del contenido incluido en la página 13
MTP R 15HD RSA D • Installation and Operation 2-11 Side Pins: RJ-45 12345678 Connector T568A T568B Video input (via transmitter) Audio/RS-232 input Pin Wire color Wire color RGB Component S-video Composite Stereo audio RS-232 1 White-green White-orange Red+/V. sync+ R-Y+ Chroma (C)+ Reserved 2 Green Orange Red–/V. sync– R-Y– Chroma (C)– Reserved 3 White-orange White-green Mono audio+ RS-232+ 4 Blue Blue Green+ Y+ Luma (Y)+ Video+ Luma (Y)– 5 White-blue White-blue Green– Y– Video– 6 Orange Gree
Resumen del contenido incluido en la página 14
Installation and Operation, cont’d For daisy-chained units, the first receiver in the chain Audio/RS-232 cable termination N must be at least 100’ from the transmitter when the Tx Rx Tx Rx Pre-Peak switch is on. For daisy-chained units, any receiver in the chain closer N RS-232 than 350’ may experience some form of over-peaking Device Bidirectional when the Pre-Peak switch is on. Tip Ground ( ) Ground ( ) Do not tin the wires! Ring Transmit (Tx) Transmit (Tx) Sleeve Receive (Rx) Rec
Resumen del contenido incluido en la página 15
Installation and Operation, cont’d MTP R 15HD RSA D Appendix A A Installation and Operation Specifications Part Numbers Decora Template Dimensions 2-14 MTP R 15HD RSA D • Installation and Operation
Resumen del contenido incluido en la página 16
Reference Information Specs file: S/N .................................................. >70 dB at maximum output (unweighted) Specifications CMRR .............................................. >43 dB @ 20 Hz to 20 kHz incorporated and E1's recom- Video Audio output mendation of cable type. Gain ................................................. Unity Number/signal type ..................... 1 mono, balanced/unbalanced Number/signal type ..................... 1 set of proprietary analog signals
Resumen del contenido incluido en la página 17
Reference Information, cont’d Temperature/humidity ................ Storage: -40 to +158 °F (-40 to +70 °C) / Part Numbers 10% to 90%, noncondensing Operating: +32 to +122 °F (0 to +50 °C) / MTP receiver and compatible transmitters and 10% to 90%, noncondensing switchers Cooling ........................................... Convection, no vents A complete transmission system requires at N Furniture mount ............................ Yes, using a standard electrical wall box or least one tr
Resumen del contenido incluido en la página 18
2.8" (7.1 cm) Reference Information, cont’d Cables Decora Template Dimensions If you need to create a template, use the dimensions shown on Enhanced Skew-Free™ A/V UTP cables are not N figure A-1, below. recommended for Ethernet/LAN applications. The drawing is not full size or to scale. Do not scale up N Enhanced Skew-Free™ A/V cable Part number or print to use as a template. Enhanced Skew-Free A/V cable 26-569-xx 2.79" (cut, various lengths) (7.09 cm) Enhanced Skew-Free A/V 1000' 22
Resumen del contenido incluido en la página 19
Reference Information, cont’d A-8 MTP R 15HD RSA D • Reference Information