Resumen del contenido incluido en la página 1
VERTICAL FLOAT SUMP PUMP
Model 95591 - .75 HP
Model 95592 - 1 HP
Model 95593 - 1.5 HP
SET UP And OPERATIng InSTRUCTIOnS
Diagrams within this manual may not be drawn proportionally.
Due to continuing improvements, actual product may differ slightly from the product described herein.
®
distributed exclusively by Harbor Freight Tools .
3491 Mission Oaks Blvd., Camarillo, CA 93011
Visit our website at: http://www.harborfreight.com
Read this material before using this product.
Failure to do so can
Resumen del contenido incluido en la página 2
4000 3500 3000 2500 2000 1500 1000 500 SPECIFICATIOnS Model 95591 Model 95592 Model 95593 Motor 115 V~ / 60 Hz / 4 A 115 V~ / 60 Hz / 5.5 A 115 V~ / 60 Hz / 6 A / 3/4 HP / 1 HP / 1.5 HP Power Switch Type Automatic Float Switch Power Plug Type 3-Prong / Grounded Self Priming Yes Maximum Pumping Capacity 3,000 GPH 3,300 GPH 3,700 GPH Maximum delivery Height 20’ 24’ 26’ discharge diameter 1-1/4 NPT Female / 1-1/2 NPT Male Max. Operating Temperature 95° Fahrenheit Performance Chart 30 KEY 25 Model
Resumen del contenido incluido en la página 3
a polarized outlet. do not change WORK AREA the plug in any way. Double insula- 1. Keep your work area clean and tion eliminates the need for the well lit. Cluttered benches and dark three wire grounded power cord and areas invite accidents. grounded power supply system. 2. do not operate power tools in 3. Avoid body contact with grounded explosive atmospheres, such as in surfaces such as pipes, radiators, the presence of flammable liquids, ranges, and refrigerators. There is gas
Resumen del contenido incluido en la página 4
information. If unreadable or miss- TOOL USE And CARE ing, contact Harbor Freight Tools for a 1. disconnect the Power Cord Plug replacement. from the power source before making any adjustments, changing 2. Wear AnSI-approved accessories, or storing the Sump safety impact eye gog- Pump. Such preventive safety mea- gles when assembling sures reduce the risk of starting the the Pump. Using per- unit accidentally. sonal safety devices reduce the risk for injury. Safety impact eye goggl
Resumen del contenido incluido en la página 5
6. do not pump hazardous materials. Any outlet should be above the Do not pump explosive or flammable water line. materials such as fuel, oil, kerosene, 11. nEVER raise or lower the Pump by gasoline, etc. Do not pump in close its electrical Power Cord. proximity to flammable or explosive materials. Do not pump fats, oils, 12. In cold weather, when the Pump salt or waste water. This Pump is is not in use, protect the interior designed to move clean or dirty of the Pump from freezing
Resumen del contenido incluido en la página 6
of electric shock. (See 3-Prong Plug gROUndIng and Outlet.) TO PREVEnT WARnIng 2. The grounding prong in the plug is ELECTRIC SHOCK connected through the green wire in- And dEATH FROM side the cord to the grounding system InCORRECT gROUndIng in the tool. The green wire in the cord WIRE COnnECTIOn: must be the only wire connected to Check with a qualified the tool’s grounding system and must electrician if you are in doubt never be attached to an electrically as to whether the ou
Resumen del contenido incluido en la página 7
2. Double insulated tools may be used dition. Always replace a damaged in either of the 120 volt outlets shown extension cord or have it repaired by in the preceding illustration. (See a qualified electrician before using it. Outlets for 2-Prong Plug.) 8. Protect the extension cords from sharp objects, excessive heat, and Extension Cords damp or wet areas. 1. Grounded tools require a three wire RECOMMEndEd MInIMUM WIRE extension cord. Double Insulated gAUgE FOR EXTEnSIOn CORdS* tools
Resumen del contenido incluido en la página 8
UnPACKIng When unpacking, check to make sure all the parts shown on the Parts List on page 12 are included. If any parts are missing or broken, please call Harbor Freight Tools at the number shown on the cover of this manual as soon as possible. ASSEMBLY And OPERATIng InSTRUCTIOnS note: For additional information regarding the parts listed in the following pages, refer to the Assembly diagram on page 13. WARnIng! Always make sure to turn off the electricity powering the Pump’s electrica
Resumen del contenido incluido en la página 9
CHECK VALVE FIgURE E OR UnIOn (nOT InCLUdEd) TO 115 VOLT, gROUndEd gFCI OUTLET dISCHARgE PIPE (nOT InCLUdEd) 1/8” AIR BLEEd HOLE o BASE (25) 3. Connect the Discharge Pipe to the Base (25). nOTE: Make sure the Discharge Pipe is secured to a solid surface, with appropriate hardware (not included), to ensure the stability of the Pump. (See Figure E.) 4. Install an additional union (not included) or other means of separating the Dis- charge Pipe just above the floor to facilitate removal of the
Resumen del contenido incluido en la página 10
6. Carefully set the Pump in place. do not lower or raise the Pump by the Power Cord or discharge Pipe. (See Figure E.) 7. The Float Switch (2) automatically switches on and off at a water depth of approxi- mately 4 inches. The ON/OFF height can be manually changed by adjusting the Float Switch Lock. CAUTIOn: Do not run the Pump dry. Doing so will increase wear to the unit and possibly cause seal damage. (See Figure E.) note: This Pump has a built-in thermal protector for the Motor wh
Resumen del contenido incluido en la página 11
2. To clean the Impeller Cover and Impeller: A clogged or dirty Impeller Cover or Impeller (28) will greatly reduce performance of the Pump. To clean the Impel- ler Cover (31), spray the Cover with clean water. To clean the Impeller, remove the nine Screws (32) at the bottom of the Base (25). Then, remove the Base to expose the Impeller Cover and Impeller. Use a stream of clean water to clean the Impeller and Impeller area inside the Pump. Then, replace the Base. (See Assy. diagram.)
Resumen del contenido incluido en la página 12
PLEASE REAd THE FOLLOWIng CAREFULLY THE MANUFACTURER AND/OR DISTRIBUTOR HAS PROVIDED THE PARTS LIST AND ASSEMBLY DIAGRAM IN THIS MANUAL AS A REFERENCE TOOL ONLY. NEITHER THE MANUFACTURER OR DISTRIBUTOR MAKES ANY REPRESENTATION OR WARRANTY OF ANY KIND TO THE BUYER THAT HE OR SHE IS QUALIFIED TO REPLACE ANY PARTS OF THE PRODUCT. IN FACT, THE MANUFACTURER AND/OR DISTRIBUTOR EXPRESSLY STATES THAT ALL REPAIRS AND PARTS REPLACEMENTS SHOULD BE UNDERTAKEN BY CERTIFIED AND LICENSED TECHNICIANS,
Resumen del contenido incluido en la página 13
ASSEMBLY dIAgRAM SKU 95591/95592/95593 For technical questions, please call 1-800-444-3353 PAGE 13 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 Power Cord/Plug not shown. 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 note: Some parts are listed and shown for illustration purposes only, and are not available individually as replacement parts. *Internal Motor Parts Are Not Consumer-Serviceable.
Resumen del contenido incluido en la página 14
LIMITEd 1 YEAR / 90 dAY WARRAnTY Harbor Freight Tools Co. makes every effort to assure that its products meet high quality and durability standards, and warrants to the original purchaser that for a period of ninety days from date of purchase that the engine/motor, the belts (if so equipped), and the blades (if so equipped) are free of defects in materials and workmanship. Har- bor Freight Tools also warrants to the original purchaser, for a period of one year from date of purchase, that all