Remote Operation Software (DX-PC For View) Table of Contents Chapter 1 ─ Overview................................................................................... 1 1.1 In This Manual ................................................................................... 1 1.2 DX-PC For View Features ................................................................. 1 1.3 Product Information ........................................................................... 1 Chapter
Resumen del contenido incluido en la página 4
User’s Manual ii
Resumen del contenido incluido en la página 5
Remote Operation Software (DX-PC For View) Chapter 1 ─ Overview 1.1 In This Manual This manual describes installation and operation of DX-PC For View (Remote Operation Software) software, which is designed to be used with remote digital video recorders (DVRs). 1.2 DX-PC For View Features DX-PC For View program is an integrated software program that controls system management, video monitoring, video recording and image playback of multiple remote sites. DX-PC For View o
Resumen del contenido incluido en la página 6
User’s Manual 2
Resumen del contenido incluido en la página 7
Remote Operation Software (DX-PC For View) Chapter 2 ─ Installation CAUTION: If an older version of DX-PC For View software is installed in your computer, you should uninstall the older version first. NOTE: In the Windows Start menu, go to Control Panel. Double click the Power Options to open the Management Properties dialog box. Under the Power Schemes tab, set both Turn off monitor and Turn off hard disks to Never. 1. Insert the installation CD. 2. Run the Setup.exe f
Resumen del contenido incluido en la página 8
User’s Manual 5. When the following dialog box appears, click Next. 6. Click Next. 7. Select whether or not to run DX-PC For View automatically when logging onto Windows, and then click Next. 4
Resumen del contenido incluido en la página 9
Remote Operation Software (DX-PC For View) 8. Set the language option by selecting either Select language when starting DX-PC For View or Always start DX-PC For View using the language below. If you select Always start DX-PC For View using the language below, select the desired startup language from the list of available languages and then click OK. NOTE: To properly display the selected language, your PC’s operating system should be set to support the selected language. 9.
Resumen del contenido incluido en la página 10
User’s Manual 10. Click Next. 11. Select I accept the terms in the License Agreement, and click Next. 12. Enter User Name and Organization, and click Next. 6
Resumen del contenido incluido en la página 11
Remote Operation Software (DX-PC For View) 13. Select Install Now. 14. Click Finish to complete the MSXML installation. 7
Resumen del contenido incluido en la página 12
User’s Manual 8
Resumen del contenido incluido en la página 13
Remote Operation Software (DX-PC For View) Chapter 3 ─ Configuration After installing the DX-PC For View software, you will find the DX-PC For View shortcut icon on the desktop. Run the DX-PC For View program by double clicking the icon. The DX-PC For View program consists of the screen, 12 docking panels, menu and toolbar. NOTE: Some panels will not be displayed on the screen in the default frame layout. To display those panels, open the View menu at the top of the screen a
Resumen del contenido incluido en la página 14
User’s Manual NOTE: There might be a problem with screen display or screen update due to low image transmission speed when using Microsoft Windows Vista or later operating system. In this situation, it is recommended that you disable the Auto Tuning capability of your computer. Run the Command Prompt with elevated administrator permissions (Go to the Start Menu → Accessories → Command Prompt → Click the right mouse button and select the Run as administrator option). Then enter “ne
Resumen del contenido incluido en la página 15
Remote Operation Software (DX-PC For View) Remote Sites Panel The Remote Sites Panel displays a list of remote sites registered during DX-PC For View System setup and a list of installed cameras at the remote sites. Entering the site name in the query box and clicking the icon allows you to find the remote site easily in the Remote Sites list. Clicking the icon allows you to register the remote site, clicking the icon removes the selected remote site from the list, and clicking
Resumen del contenido incluido en la página 16
User’s Manual The Map panel pops up another screen when alarm-in, motion or video loss events are detected or when you click the device icon according to the Map Editor settings. Change the popup screen location by clicking the left mouse button on the screen and dragging it to where you want it located. Clicking the right mouse button on the popup screen displays the following popup menu. x0.25 to x2: Sets the desired size of the Map popup screen. Full Screen: Enters
Resumen del contenido incluido en la página 17
Remote Operation Software (DX-PC For View) PTZ, Color and Alarm Out Control Panels Three panels allow PTZ control, color control, and alarm out control while live monitoring a remote site. NOTE: Refer to 4.1 Live Monitoring for more details. Image Processing Panel The Image Processing panel allows enhancing played back images. NOTE: Refer to 4.2 Playback and Search for more details. Watch Event View Panel The Watch Event View panel displays event
Resumen del contenido incluido en la página 18
User’s Manual Alarm-In On Alarm-In Off Motion Detection Object Detection Video Loss Video Blind Text-In Alarm-In Bad Recorder Bad Disk S.M.A.R.T. Disk Bad Disk Full Disk Almost Full Disk Config Change Disk Temperature Panic Recording Off Fan Error On Panic Recording On Fan Error Off System Boot Up System Alive System Restart System Shut Down Video Analytics Detection Audio Detection NOTE: Some event icons may not be supported, dependi
Resumen del contenido incluido en la página 19
Remote Operation Software (DX-PC For View) The Report View panel displays the system status information of remote sites. DX-PC For View checks the remote site and reports system status. Clicking the icon on the panel reloads the data and clicking the icon prints the report out. Report Setup must be configured during DX-PC For View System setup for this feature to function. Refer to 3.3 Menu – System Menu for more details. NOTE: Some report options may not be supported, dependin
Resumen del contenido incluido en la página 20
User’s Manual 3.3 Menu System Menu Setup: Allows setting up the system operation and remote site configuration. System 1: Set up the date/time format for DX-PC For View, display option, and panic recording function. 16