Resumen del contenido incluido en la página 1
® ®
Polycom KIRK
Wireless Server 8000
Installation Guide
Resumen del contenido incluido en la página 2
Copyright © Polycom, Inc. All Rights Reserved Catalog No. 14184630_Hd.1 Version 1 Proprietary and Confidential The information contained herein is the sole intellectual property of Polycom, Inc. No distribution, reproduction or unauthorized use of these materials is permitted without the expressed written consent of Polycom, Inc. Information contained herein is subject to change without notice and does not represent commitment of any type on the part of Polycom, Inc. Polycom and Accord are re
Resumen del contenido incluido en la página 3
Contents Contents KWS8000 Installation Installing the KWS8000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–1 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–1 General Installation Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–2 Installing the KWS8000 in a Rack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–2 Installing the KWS 8000 on a Flat Surface
Resumen del contenido incluido en la página 4
1 KWS8000 Installation This guide describes how you install the KWS8000. Installing the KWS8000 The KWS 8000 can be installed in a rack, on a flat surface or on a wall using the KWS8000 Wall Hanger. Before you start the installation, place the KSW 8000 on a stable flat surface in the selected location, and inspect the package for any damage and report it to the reseller or distributor immediately. Important Please review all the safety instructions for important safety and regulatory informa
Resumen del contenido incluido en la página 5
Polycom KIRK Wireless Server 8000 Installation Guide Table 1-3 Power consumption Power consumption Typical AC Power Consumption 90 Watt Max. AC Power Consumption Max 360 Watt Table 1-4 Environment Environment Operating temperature 0°C - 40°C (22° - 104°F) Storage temperature -30°C - 70°C (40° - 158°F) Relative humidity 20% - 80% Non condensing Operating altitude Up to 2,000 m (6,500 ft) Operating ESD level 4 KV General Installation Information The maximum number of KWS 8000 units that can be lin
Resumen del contenido incluido en la página 6
KWS8000 Installation Rack mounting Safety Precautions. • Ensure that the leveling jacks on the bottom of the rack are fully extended to the floor with the full weight of the rack resting on them. • In a single rack installation, stabilizers should be attached to the rack. • In multiple rack installations, the racks should be coupled together. • Always make sure the rack is stable before extending a component from the rack. • You should extend only one component at a time - extending two or mor
Resumen del contenido incluido en la página 7
Polycom KIRK Wireless Server 8000 Installation Guide Figure 1-1 Rack Installation Installing the KWS 8000 on a Flat Surface Before you start installation take notice of the following safety precautions. Flat Surface Mounting Safety Precautions • Ensure the surface can support the weight of the unit. • Never install the KWS8000 on the floor. • Never place anything, except ONE additional KWS8000 unit, on top of the KWS8000. The top plate must be free to allow sufficient cooling. To Install the KW
Resumen del contenido incluido en la página 8
KWS8000 Installation 2 Before placing the unit, carefully turn it upside down and mount the four rubber pads supplied in the package. One must be placed at each corner of the bottom plate. 3 Place it on a clean, flat, horizontal surface. Installing the KWS8000 on a Wall Before you start installation take notice of the following safety precautions. Wall Mounting Safety Precautions • Ensure the wall quality is good enough for holding the unit. Avoid high-porous surfaces, joints and similar. • N
Resumen del contenido incluido en la página 9
Polycom KIRK Wireless Server 8000 Installation Guide 2 Mount the wall hanger securely using four screws. Use rawlplugs, expansion bolts or other appropriate fastening methods in relation to the wall material. 3 Remove drilling dust, unpack the KWS8000, fit it into the wall hanger, and then fasten the two front screws. Figure 1-3 Fitting the kWS8000 into the wall hanger Connecting the KWS8000 Cables When the KWS8000 has been mounted, the cables can be connected. Cable Safety Precautions Before
Resumen del contenido incluido en la página 10
KWS8000 Installation • The interface cables must be removed before any interface card is removed or replaced. • When unplugging power, unplug AC mains power first before unplugging the power connector from the KWS8000. • The AC adapters must never be hanging by their own weight in the AC mains connector or the output connector. To Connect Power Cables The KWS8000 has four power plugs on the back panel behind the sliding doors: • System Power Backup • System Power Primary • 4+ BIF Power Backu
Resumen del contenido incluido en la página 11
Polycom KIRK Wireless Server 8000 Installation Guide The unit configuration determines which plugs to use. Connect the plugs according to the following table. Table 1-5 Cable plugs overview Nbr BIF SYS SYS 4+ BIF 4+ BIF BIF Card Card Redun- PWR PWR PWR PWR Place- # s dancy Primary Backup Primary Backup ment 1 ≤4 No Connect No No No Slot 4-7 Connect Connect Connect 2 ≤4 Yes Connect Connect No No Slot 4-7 Connect Connect 3 >4 No Connect No Connect No Slot 0-7 Connect Connect 4 >4 Yes Connect Co
Resumen del contenido incluido en la página 12
KWS8000 Installation Figure 1-5 Storing room for two AC power adapters If more than two AC power adapters are used, these must be kept on a flat surface (same requirements as for the KWS8000 unit). In a rack installation the power adapters can be kept on a tray installed for the purpose provided that the ambient temperature is below 32ºC, and they have free air surrounding them. Installing Interface Cards and CPU Cards Before you install an interface or a CPU card ensure to take the followin
Resumen del contenido incluido en la página 13
Polycom KIRK Wireless Server 8000 Installation Guide Figure 1-6 Installing Interface cards 2 Plug the interface cables into the card as described in “Connecting Interface Cables” on page 1-11. To Install CPU Cards 1 Ensure that the KWS8000 is powered off completely. 2 With two hands, gently slide the card into the unit. Give the card a gentle push on the last centimeter so that it enters the backplane connector properly. Avoid pushing on the front connectors - push only on the plastic parts
Resumen del contenido incluido en la página 14
KWS8000 Installation Figure 1-7 Installing CPU card 3 Plug the interface cables into the card as described in “Connecting Interface Cables” on page 1-11. 4 Connect the power and reboot the unit. Connecting Interface Cables The front interface of the KWS8000 is provided with connectors for the different interfaces provided. Please see the KWS8000 User Guide for the actual pin-out of the different connectors. The cables can be harnessed in two ways as shown in the following figures depending o
Resumen del contenido incluido en la página 15
Polycom KIRK Wireless Server 8000 Installation Guide Figure 1-8 Harnessing cables to the back and out 1–12
Resumen del contenido incluido en la página 16
KWS8000 Installation Figure 1-9 Harnessing cables to the side and out. Regardless of which way is used for harnessing, you must guide the cables through the opening in the plastic front. This ensures safe retention of the cable. 1–13
Resumen del contenido incluido en la página 17
2 Replacing Components The KWS8000 is designed to minimize down-time. Several components can be replaced while the system is up. Component Replacement The following components are hot-swappable: • Interface cards • AC adapters The following require a power down of the system: • Backplane • CPU card Before replacing any components, take notice of the component replacement precautions. 2–1
Resumen del contenido incluido en la página 18
Polycom KIRK Wireless Server 8000 Installation Guide Component Replacement Precautions • Cards contain static sensitive circuitry and may be destroyed or damaged by electrostatic discharge (ESD.) • All maintenance tasks must be performed by qualified, authorized personnel only. • Use only original replacement parts. • Make sure you are using proper ESD equipment, to prevent damage to the system. • Fill all empty slots with blanking front plates to close the front. Replacing Interface and CPU
Resumen del contenido incluido en la página 19
Replacing Components 7 Plug the interface cables into the card. 8 Connect power and reboot the unit. Replacing the Backplane The backplane cannot be replaced on-site. The chassis will have to be returned for repair or be replaced with a new one. If a new chassis is to be installed, you can move the cards from the faulty chassis to the new one. To Replace an AC Adapter. >> Check to see if unit has a backup supply attached. If yes, then unplug the faulty one and replace it with a new one. >> If
Resumen del contenido incluido en la página 20
3 Regulatory Notices This section contains important safety regulations for the KWS8000. International Regulatory and Product Information United States Federal Communication Commission (FCC) Part 15: Class A Statement. This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. Test limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment