Resumen del contenido incluido en la página 1
ADDENDUM
Addendum No. C1573M
Date February 1, 2006
Manuals Affected C1572M, C1555M-F, C1566M-C
Manual Update The front and rear mounting rails and the mounting brackets are no longer supplied with the CM9700-CC1.
Disregard the CM9700-CC1 mounting information in the above referenced manuals.
To mount the CM9700-CC1 into a standard 19-inch EIA rack follow these instructions:
1. Insert the CM9700-CC1 into the rack.
2. Tighten the CM9700-CC1 to the rack using the four supplied Phi
Resumen del contenido incluido en la página 2
INSTALLATION/OPERATION System 9770 ® C1555M-F (10/05)
Resumen del contenido incluido en la página 3
Resumen del contenido incluido en la página 4
Contents Contents. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 List of Illustrations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 Description . . . . . . . . . . .
Resumen del contenido incluido en la página 5
List of Illustrations 1 CM9770-MXB Mounting Baffle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10 2 Mounting the CM9770-MXB on Top of the Mounting Baffle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11 3 Mounting the CM9700-CC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Resumen del contenido incluido en la página 6
List of Tables A LEDs Illuminated During a Basic Check . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16 B Data Connections—Single Node Systems Without a Hot Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31 C Data Connections—Networked System Without a Hot Switch . . . . . . . . . . . . . . . . . . . . . . .
Resumen del contenido incluido en la página 7
Description The System 9770 is a full-featured video matrix switching control system that allows users to view and control up to 2,048 cameras and 512 monitors on a single node. The System 9770 has the following basic components: • CM9700-CC1—This is the system CPU; connect matrix bays, keyboards, PTZ camera control lines, and peripheral devices to the CC1. • CM9770-MXB—This is the video matrix (switching) bay with video input/output modules; connect cameras, monitors, VCRs, and other v
Resumen del contenido incluido en la página 8
MODELS Controller and CPU Components CM9700-CC1 CPU controller; 120 VAC, 60 Hz or 230 VAC, 50 Hz. CM9700-SER Serial communication card (RS-422 SERCOM); provides 8 communications ports to interface peripheral equipment (4 maximum per CPU). CM9700-SER-32 Port expansion unit; 32 serial communication (SERCOM) ports per unit. Up to three units can be added to a CC1. (Check with Pelco Systems Applications Department before adding to an existing CM9700-CC1). Includes interconnecting cables
Resumen del contenido incluido en la página 9
Keyboards The following keyboards are compatible with the System 9770: CM9760-KBD Full-function desktop variable-speed keyboard; 120 VAC, 60 Hz. CM9760-KBD-X Same as CM9760-KBD except 230 VAC, 50 Hz. CM9760-KBR Full-function 19-inch EIA rack mount keyboard; 120 VAC, 60 Hz. CM9760-KBR-X Same as CM9760-KBR except 230 VAC, 50 Hz. NOTE: CM9760-KBD software version 8.03 or higher is required. KBD200A Desktop keyboard with full switching capabilities, plus push-button control of PTZ
Resumen del contenido incluido en la página 10
Installation UNPACKING 1. Unpack and inspect all equipment, and verify delivery according to the packing slip. Before shipping, Pelco connects, tests, and programs each system according to the individual sales order. Contact Pelco immediately if there is any discrepancy in the equipment that you receive. CM9700-CC1 The following items are supplied with the CM9700-CC1: • 1 CM9700-CC1 unit, with front rack ears installed • 1 120 VAC, 60 Hz power cord (USA standard) • 1 230 VAC, 50 Hz
Resumen del contenido incluido en la página 11
MOUNTING Install the System 9770 in EIA-standard 19-inch (48.26 cm) racks. CM9770-MXB 1. Install the CM9770-MXB mounting baffle first (refer to Figure 1). The mounting baffle uses 1 rack unit (RU), and it has front and rear mounting ears, which are attached to the front and rear mounting racks. The rear mounting brackets are adjustable to allow for different depths of cabinets. NOTE: Be sure to use all eight screws provided with the mounting baffle. The mounting baffle must be ins
Resumen del contenido incluido en la página 12
Figure 2. Mounting the CM9770-MXB on Top of the Mounting Baffle (Optional) Install additional CM9770-MXB mounting trays and matrix bays to the side of and below the first unit, as necessary. WARNING: Always install equipment starting from the bottom of the rack frame or cabinet. Installing equipment from the top down will make a rack or cabinet top heavy and could cause the equipment to tip over. NOTE: Each CM9770-MXB has a unique label for identifying the bay location in the
Resumen del contenido incluido en la página 13
c. Attach the ear of the rear-mounting support rail to the rear of the equipment rack using four 10-32 x 0.375-inch flat head screws. (The holes in the ear of the rail should align with the threaded holes in the equipment rack.) 4. Tighten the three 8-32 x 0.375-inch pan head screws and washers that were attached to the front- and rear-mounting support rails in step 2 above. 5. Repeat steps 3 and 4 for the second set of support rails. 6. Place the CC1 onto the support rails and slide t
Resumen del contenido incluido en la página 14
VIDEO INPUT/OUTPUT CONNECTIONS The following steps provide an overview of how to connect video input and output sources. More complete procedures are provided in the subsequent sections. NOTE: If your System 9770 is configured by Pelco, the appropriate number of video input cards and monitor output cards and BNC rear panels are installed at the factory, and steps 1 and 2 are not necessary. If this is the case, skip to Step 3. 1. Install the CM9770-VCC and CM9770-VMC ca
Resumen del contenido incluido en la página 15
INSTALLING VIDEO INPUT CARDS (CM9770-VCC) The first video input card is inserted into slot 1; the next card is inserted into slot 2 (refer to Figure 4). To add a video card, slide the card into the first available slot. The CM9770-MXB can contain a maximum of eight viideo input cards. HOT SWAPPING: You can “hot swap” a video input card—remove a card and/or insert a new card—while the system is powered and running. When you hot swap a card, the CM9770-MXB automatically verifie
Resumen del contenido incluido en la página 16
INSTALLING MONITOR OUTPUT CARDS (CM9770-VMC) The monitor output card located in slot 10 is the primary card, and it handles video for monitors 1-16. Refer to Figure 5. Note that the CM9770-MXB will not function without a CM9770-VMC card inserted into slot 10. An optional secondary VMC card can be installed in slot 9. This card routes video for monitors 17-32. HOT SWAPPING: You can “hot swap” a monitor output card—remove a card and/or insert a new card— while the system is powere
Resumen del contenido incluido en la página 17
PERFORMING A BASIC LED CHECK You should perform a basic LED check before you connect any video input or output to the matrix bay. The LED check allows you to ensure that the system is operating properly. 1. Turn on the power switch on the rear of the matrix bay. The front cover can either be open or closed during the LED check. 2. Various LEDs will blink during the initialization process as the software verifies communication and version level information. Once the initia
Resumen del contenido incluido en la página 18
INSTALLING REAR PANEL BNC CARDS The following rear panel cards can be used with the CM9770-MXB matrix bay: • CM9770-RPC—the BNC card for video connections • CM9770-RPM—the BNC card for monitor connections • CM9770-DFC—this is a downframe card and cable assembly used to connect multiple matrix bays; refer to the Downframing section in the Appendix for more information • CM9770-DFL—this downframe card and cable assembly is the same as the CM9770-DFC, except that it also ha
Resumen del contenido incluido en la página 19
Change the Termination Jumpers on a Rear Panel Video BNC Card In a single-bay, non-looping configuration (up to 256 cameras and 32 monitors), the jumpers must be set in the terminated position. Refer to the Installing Additional Matrix Bays—Sideframing and Downframing section in the Appendix for details on termination jumper settings in multiple- bay configurations. When looping video out to another device (such as a DVR, VCR, or switcher), set the termination jumpers on the CM9770-R
Resumen del contenido incluido en la página 20
Looping Video When looping video out to another device (such as a DVR, VCR, or switcher), the connection instructions depend on the size of your system, as follows: • In a system containing 32 monitors or fewer (the video is not downframed), use the CM9700-VPP panels to loop the video out. Connect the DFC cables that are provided with the VPP panel to the connectors on the bottom of the matrix bay RPC cards, as shown in Figure 10. When looping video, set the termination jumpers