Resumen del contenido incluido en la página 1
Speed Dome
EPTZ900/500
USER MANUAL
Date: June 2006
Resumen del contenido incluido en la página 2
Table of Contents 1. EPTZ900/500 OVERVIEW ................................................ 1-3 1.1. Introduction .............................................................................................1-3 1.2. Specifications ..........................................................................................1-5 1.3. Feature .....................................................................................................1-7 1.3.1. Profile of EPTZ900/500 ................
Resumen del contenido incluido en la página 3
2.4.1. Installation Requirements .............................................................. 2-20 2.4.2. EPTZ900 Dome Camera Wall Mount Installation ......................... 2-20 2.4.3. EPTZ500 Dome Camera Installation ............................................. 2-24 2.5. Separately Sold Accessories ................................................................ 2-27 2.5.1. Pole mount ...................................................................................... 2-27 2.5
Resumen del contenido incluido en la página 4
1. EPTZ900/500 OVERVIEW 1.1. Introduction EPTZ900/500, an intelligent high-speed dome camera is ready to secure your property with its omni-directional and exact monitoring. An 18X optical and 12X digital zoom combining with a high-performance chip makes captured images clear and vivid. The other powerful camera functions this type of speed dome equips with: PAL / NTSC image format suppose. Auto and fast focus increases the searching speed and precision. Auto Iris adjusts the monitori
Resumen del contenido incluido en la página 5
All of the features make the intelligent high-speed dome camera works for a wide range and demanding application such as banks, airports, stations, casinos, streets of cities, intelligent buildings, and etc. 1-4
Resumen del contenido incluido en la página 6
1.2. Specifications Model EPTZ900 EPTZ500 Pickup Device 1/4" type Sony Super HAD CCD Video Format NTSC or PAL Scanning System NTSC: 525 TV lines, 60 fields/sec PAL: 625 TV lines, 50 fields/sec Picture Elements 768 x 494 ( NTSC ) , 752 x 582 ( PAL ) Horizontal Resolution 480 TVL Sensitivity 1.0 Lux/F=1.4 S/N Ratio (AGC OFF) Over 50dB Electronic Shutter 1/50~1/10,000 (s) Digital Slow Shutter No Shutter Selection No Lens Type 18x optical zoom , f=4.1 mm (wide) to 73.8mm (tele) , F1.4
Resumen del contenido incluido en la página 7
1-239 grade available,0.1º/s - 360º/s Running To Position Speed Dwell Time At Preset Position 1-239 second available Tour 16 group Tour Point Per Group 16 preset positions Fan, Heater (EPTZ900) Fan & Heater auto starts No Position Accuracy ±0.1° Alarm 4 in 1 out with tour/position auto triggering Proportional Pan Speed Yes Built-in menu for functions Yes Built-in Protocols Auto, EVF, Plus-D, A-Type, Pelco-D, Pelco-P Communication RS485 Address editable through DIP Yes switch Spe
Resumen del contenido incluido en la página 8
1.3. Feature 1.3.1. Profile of EPTZ900/500 EPTZ900 Wall Mount Bracket M5 Bolt (Hex) x3 Base PCB board Control board Connection Bus Housing Power Cable Inner Housing BNC Cable RS485 Cable M3 Bolt x3 Mechanical Part Bulb Camera Module EPTZ500 Power Cable Base PCB board BNC Cable RS485 Cable Control board Housing Clip Connection Bus Mechanical Part Ceiling Button Camera Module Bulb 1-7
Resumen del contenido incluido en la página 9
1.3.2. Base Board The base board that is on the bottom of the housing connects to power cable, video cable, control cable, alarm cable, fan and heater (fan and heater are for EPTZ900 only). In order to connect to cables, the board needs to be taken off, and put back after finishing connecting to all cables. The connectors of cable names are marked on the board in white text. The details of the alarm connector (JP5) are shown on the APPENDIX A. For EPTZ900, JP1, JP3 and JP6 that are tw
Resumen del contenido incluido en la página 10
ON 123 456 78 ON 12 345 678 JP5 RELAY EPTZ500 Baseboard 1.3.3. EPTZ900/500 Control Board The PCB board with two dipswitches is the control board of speed dome. The two switches are used to set address, protocol, Baud Rate, video format and terminator resistance. CPU SW2 ID1 ID2 ID3 ID4 ID5 ID6 ID7 ID8 SW1 1-9 Video + Video - RS485 + RS485 - AC24 AC24 BAUD Protocol
Resumen del contenido incluido en la página 11
1.4. EPTZ900/500 Connection 110V AC 24V AC POWER 24V AC / 3.5 A Adapter BNC Video Out 1.0Vpp ± 0.2V, 75 Ω RS485 Tx(+) RS485 Control Line RS485 Tx(-) Alarm 1 EPTZ900/500 Alarm 2 Alarm 3 4 ALARM INPUTS Alarm 4 GROUND ALARM OUTPUTS N.C. N.O. COM 1-10
Resumen del contenido incluido en la página 12
1.5. EPTZ900/500 Quick Operation Guide (Work with EKB500) EPTZ900/500 and EKB500 (Keyboard) can work together by using factory default setting. You just need to connect cables by following the steps: 1. Connect the RS485 cable to EPTZ900/500 and a Keyboard (EKB500). 2. Connect a video cable from EPTZ900/500 to a monitor. 3. Connect the power to the EPTZ900/500 and a Keyboard (EKB500) . After the speed dome finishes the self-test mode, you can start to operate the speed dome via the keyboa
Resumen del contenido incluido en la página 13
2. EPTZ900/500 INSTALLATION 2.1. Packing List There are 3 boxes that are housing, bulb and mechanical part with a camera module, one wall mount bracket, one power adapter and one accessory packet in the package. The detail accessories list below: Housing x1 Bulb x1 Mechanical part with a camera module x1 Wall mount bracket x1 Adapter x1 Accessory packet Glove x2 M5 Hex Allen wrench x1 Pin connector x1 M5 screw (Hex) x3 for wall mount bracket fixing M3 screw x3 for bulb
Resumen del contenido incluido en la página 14
Video Cable A BNC cable is used for connecting a speed dome to a DVR or a monitor. An amplifier may be needed if the video cable is too long. Control Cable Basically, EPTZ900/500 uses a differential pair to connect to other devices by cascading. A cable that has low signal decline can be used as a control cable. Alarm Cable An alarm cable is not included in the packing list. A suitable wire can be used as an alarm cable. 2.3. Initial Setup Initial setup includes dome address
Resumen del contenido incluido en la página 15
ON 12 34 567 8 ON 1 234 56 78 2.3.1. Address Setting The address code of the EPTZ900/500 should be set to correspond properly with a control device to control multiple dome cameras. The address codes are made up by the dipswitch SW1 (8 bits) on the PCB board. The 8 bits dipswitch indicates the binary 8 coded of the address, and there are 256 addresses can be selected (0 ~ 255, 2 = 256). It also means that there up to 256 dome cameras can cascade on the RS485 bus. The dipswitch setting and
Resumen del contenido incluido en la página 16
Switch Address Sw Sw Switch i it tch ch Ad A Ad ddress d dr re es ss s S Sw Sw Sw wii i itch t t tch ch ch A Address Address Address ddress Sw Sw Sw Sw Swi i i i it t t t tch ch ch ch ch Addre Add Add Add Addr r r re e e es s s s ss s s s s ON ON ON ON 0 32 64 96 1234 5678 12 3456 78 1234 5678 1 23456 78 ON ON ON ON 1 33 65 97 1234 5678 12 3456 78 1234 5678 1 23456 78 ON ON ON ON 2 34 66 98 1234 5678 12 3456 78 1234 5678 1 23456 78 ON ON ON ON 3 35 67 99 1234 5678 12 3456 78 1234 5678 1 23456 78
Resumen del contenido incluido en la página 17
Switch Address Sw Sw Switc itc itch h h Addres Addres Address s s Sw Sw Sw Switch it it itch ch ch Add Add Addre Addr r re e es s s ss s s s Sw Sw Sw Sw Swiitch itch itch itch tch A Address Address Address Address ddress ON ON ON ON 128 160 192 224 12345678 1 2345678 1234 5678 12345678 ON ON ON ON 129 161 193 225 12345678 1 2345678 1234 5678 12345678 ON ON ON ON 130 162 194 226 12345678 1 2345678 1234 5678 12345678 ON ON ON ON 131 163 195 227 12345678 1 2345678 1234 5678 12345678 ON ON ON ON 132
Resumen del contenido incluido en la página 18
ON ON 123 45 678 12 3 45 67 8 ON ON 123 45 678 12 3 45 67 8 ON ON 123 45 678 12 3 45 67 8 ON ON 123 45 678 12 3 45 67 8 ON ON 12345 678 12 34 56 78 2.3.2. Communication Protocol Setting st nd rd The 1 , 2 and 3 bits of the SW2 are used to set communication protocol. The factory default protocol is EVF. EVF - 1 PELCO-D PELCO-P TYPE-A SW2 Protocol Baud Rate PAL / NTSC Maching Resistance Notice: Please make sure the power is off before setting, and restart the speed dome to enable a new v
Resumen del contenido incluido en la página 19
ON ON 12345 6 78 123 45 67 8 ON ON 12345 6 78 123 45 67 8 ON ON 12345 678 123 45 67 8 2.3.4. Video Format Setting th The 6 bits of the SW2 on the PCB board are used to set the video format. The default video format depends on the factory setting. Please do not change it. NTSC PAL SW2 Protocol Baud Rate PAL / NTSC Maching Resistance Notice: Please make sure the power is off before setting, and restart the speed dome to enable a new value after changing. 2.3.5. RS-485 Bus Terminator R
Resumen del contenido incluido en la página 20
n ≦ 255 RS485 Keyboard DVR Ternimator Control Unit CAM-0 CAM-1 CAM-n Resistance ON Note: When the dome is out of control, or does not work under control well, try to switch the terminator resistance ON. Notice: Please make sure the power is off before setting, and restart the speed dome to enable a new value after changing. 2-19