Resumen del contenido incluido en la página 1
WARNING
This equipment has been tested and found to comply with the limits for a Class A
digital device, pursuant to Part 15 of FCC Rules. These limits are designed to
provide reasonable protection against harmful interference in a residential
installation. This equipment generates, uses and can radiate radio frequency energy
and, if not installed and used in accordance with the instructions, may cause
WWS800/850 Bluetooth Wireless Scanners
harmful interference to radio communic
Resumen del contenido incluido en la página 2
4.4.3 Clear Data ...................................................................................... 13 Table of Contents 4.4.4 Send Data........................................................................................ 13 4.4.5 Memory Data Delay........................................................................ 13 1. INTRODUCTION...........................................................................................1 5. BLUETOOTH SERIAL PORT................................
Resumen del contenido incluido en la página 3
8. DATA OUTPUT FORMAT.........................................................................29 8.1 CHARACTER SUBSTITUTION.....................................................................29 8.2 PREFIX / POSTFIX CODE...........................................................................29 8.3 CODE ID ..................................................................................................29 8.4 LENGTH CODE .....................................................................
Resumen del contenido incluido en la página 4
1. Introduction 2. Base Installation The WWS800/850 kit contains: This manual described how to operate and configure the WWS800/850 Wireless A WWS800/850 wireless barcode scanner Barcode Scanner and is divided into two sections. The first section describes the A base installation, operation and programmable features of the scanner. The second A rechargeable battery section contains the setup barcodes used to configure the scanner. A Serial/Keyboard/USB Cable (depending on configura
Resumen del contenido incluido en la página 5
2.2 Power Up the WWS800/850 2.4 Charging your WWS800/850 When you receive your WWS800/850, the battery will be packaged separately. There are three methods to charge the battery. One is placing the scanner on the Please insert the battery into the bottom of the scanner and lock the battery into base and another is inserting the battery in front of the base, and the other is place by pushing up on the clip. The scanner will beep and the LED will be light inserting the power supply into the
Resumen del contenido incluido en la página 6
3. General Features 2.4.3 DC Jack 3.1 Buzzer The buzzer of the scanner beeps differently to indicate various operating conditions. • Power On Beep: The scanner will issue a long beep to indicate a successful power on. • Good Read Beep: The system provides four volume levels and four beeping Insert the power supply to the DC Jack at bottom of the scanner. When charging, tones (frequencies) that the user can select from to si
Resumen del contenido incluido en la página 7
• Continuous Mode: The scanner is always scanning. 3.5 Re-read Delay • Auto Power Off Mode: The scanner will start scanning once the switch is triggered. The scanning continues until a preset scanning period (Scanner If the scanner mode is set to Continuous, Auto Power Off, Alternate, or Momentary Time-Out Duration) is expired. Unlike the Auto Off mode, the scanner will mode, the scanner will prevent accidentally reading the same barcode twice by continue to scan and the scanning period
Resumen del contenido incluido en la página 8
• EAN8 (with or without Addon) 4. Output Interface (Base Unit) • EAN13 (with or without Addon) • Code 93 The WWS800/850 is a multi-interface scanner. It can be used as a keyboard wedge • Code 128 scanner, an RS-232 scanner, or a USB scanner. The output interface can be • EAN 128 programmed using the setup barcodes in this manual. • MSI Please ensure that you have an RF connection between the scanner and the base • Telepen prior to selecting the interface type. • Plessey 3.9 Negat
Resumen del contenido incluido en la página 9
4.2 RS232 Interface 1 2 3 4 ! @ # $ User can select the desired, flow control, baud rate, parity, and data bits to be used Digits on Upper Row in this output interface. 4.2.1 Baud Rate / Parity / Data Bits 4.1.4 Capital Lock Status The supported baud rate, parity, and data bit are listed below. In order to send alphabets with correct case, the scanner needs to know the capital • Baud Rate: 115200 / 3
Resumen del contenido incluido en la página 10
the scanner is out of signal range and data will transmitted to server when the 5. Bluetooth Serial Port scanner is back to the service range. The WWS800/850 can work offline and store the reading data into the internal Flash memory for later upload to the host. The stored data can be up to 128Kbytes. The WWS800/850 can be configured to the standard Bluetooth Serial Port as the data output interface. This will make the WWS800/850 send the scanned barcode data to Bluetooth enabled comput
Resumen del contenido incluido en la página 11
the initial (first time) connection setup, this setting must be enabled. User can 6. Bluetooth HID disable this setting for security reasons after initial connection setup is completed. 5.1.4 Update Settings The 800/850 scanner can be configured to the standard Bluetooth HID as data output interface. This will make the 800/850 scanner sends the scanned barcode After all the desired settings are completed, the “Update” barcode must be scanned data to Bluetooth enabled computer or PDA dir
Resumen del contenido incluido en la página 12
6.1.2 Reset Connection The digit layout style can be changed by the following configuration settings. There are three options: Default, Lower Row, and Upper Row. The scanner will Scan the “Reset Connection” when switch connection from one PC to another PC. make necessary adjustment when sending digits according to the setting value of The scanner will re-start itself after this barcode is read. this parameter. This setting is used with the above setting (Keyboard Style – Alphabets) and per
Resumen del contenido incluido en la página 13
6.3 Configuring Bluetooth Device Driver Please follow the procedures below to configure the Bluetooth driver on the host system. Please note that, when searching nearby Bluetooth devices on Host computers, the 800/850 scanner will come out with the serial number as their device name. Please check the serial number label on the scanner when making 2. Select the 800/850 scanner and click Next button. connections. 6.3.1 Windows XP with Service Pack2 1. Insert the Blueto
Resumen del contenido incluido en la página 14
3. Right click the 800/850 scanner and select Pair Device. 8. The scanner is ready to use. Please click OK button. 4. Input PIN code and click OK button. 6.3.2 Widcomm Bluetooth Driver 5. Right click 800/850 scanner and select Discover Available Services. 1. Click icon at PC. 2. Click Find Bluetooth Devices icon at My Bluetooth Places. 22 21
Resumen del contenido incluido en la página 15
6. Click PC Remote Commander icon. 7. Symbology Parameters This section describes user configurable parameters that are pertaining to barcode symbologies. 7.1 Code39 • Standard / Full ASCII Code 39: User can choose to read either Standard Code 39 or Full ASCII Code 39 by configuring this parameter. • Start/Stop Transmission: This parameter specifies whether the start/stop 7. Click Yes Button. characters of Code 39 are included in the data being transmitted. • Checksum Ve
Resumen del contenido incluido en la página 16
• Checksum Transmission: This parameter specifies whether the checksum • System Number Transmission: If this parameter is enabled, the system character is included in the data being transmitted. number will be included in the data being transmitted. • Code Length Qualification: Because of the weak structure of the 2 of 5 • Checksum Transmission: If this parameter is enabled, the checksum codes, a partial scan has a high probability of decoding as a valid but shorter character will be included
Resumen del contenido incluido en la página 17
• Checksum Verification: Three kinds of checksum calculations can be • Code ID Transmission: If this parameter is enabled, the Code ID selected implemented into MSI code: Single Modulo 10, Double Modulo 10, or by the preceding setting will be included in the data being transmitted. Modulo 11 & 10 checksum. If the checksum character is incorrect, the • Application ID Transmission: If this parameter is enabled, the Application barcode will not be read. ID will be included in the data being tr
Resumen del contenido incluido en la página 18
Set 1 Set 2 Set 3 Set 4 Set 5 8. Data Output Format Code 39 A C Y M A Italy Pharmacode A C Y M A French Pharmacode A C Y M A Data read by the scanner will be processed in the following sequence (RS-232, Industrial 25 C H H H S Keyboard Wedge and USB interfaces). Interleave 25 D I Z I S 1) The character substitution is performed on the barcode data. Matrix 25 E G G G S 2) The Code ID and the Length Code are inserted at the beginning of the data as Codabar F N X N F shown below. Co
Resumen del contenido incluido en la página 19
9.3 Applicable Conditions 9. Data Editing Three applicable conditions can be configured to qualify whether the data read by The WWS800/850 scanner provides advanced data editing functions for data the scanner can be processed by the particular editing format. Data editing will not formatting. Data editing is performed according to user configured editing formats. be performed unless all three applicable conditions are met. The configurable Up to three editing formats can be configured
Resumen del contenido incluido en la página 20
always included in the field. User though, has the option of discarding this 9.10 Exclusive Data Editing terminating string. • Field Length: The field division can be simply specified by the field length. If this parameter is enabled, all data read by the scanner must be processed by the The scanner will assign the next specified number of characters into the editing format. If the data is not eligible for all enabled editing formats, the scanner field. will not accept the reading and