Resumen del contenido incluido en la página 1
QS200
Handheld Scanner
Programming Manual
v 2.1
Resumen del contenido incluido en la página 2
PSC Inc 959 Terry Street Eugene, Oregon 97402 Telephone: (541) 683-5700 Fax: (541) 345-7140 All rights reserved. No part of the contents of this documentation or the procedures described therein may be produced or transmitted in any form or by any means without prior written permission of PSC Inc. Owners of PSC Inc.'s products are hereby granted non-exclusive, revocable license to reproduce and transmit this docu mentation for the purchaser's own internal business purposes. Purchaser shall no
Resumen del contenido incluido en la página 3
TABLE OF CONTENTS Introduction Flow Chart 1 Interfaces 2 On/Off Symbologies 3 Code 39 7 Codabar/NW7 8 Interleaved 2/5 9 Standard 2/5 11 Matrix 2/5 12 EAN-13/EAN-8 13 UPC-A/UPC-E 14 CHINESE POSTAL 2/5 15 Reading Modes 16 General Parameters 17 Keyboard Parameters 20 Terminal Type 21 Function Key Setting 23 Function Key Table 24 Function Key Labels 25 Languages
Resumen del contenido incluido en la página 4
RS232 Parameters 28 CCD Wand Emulation 31 OCIA Types 32 Magnetic Setting 33 Code Mark 34 Truncate Digits 36 ASCII Table 38 Hexadecimal Labels 39 Pinout Assignments 40 Notes: 1. Options marked by { } are only available for some models. 2. Factory default values are indicated by . 3. All references to numbers in this menu are in Decimal, but you MUST input it as Hexadecimal. Ii
Resumen del contenido incluido en la página 5
INTRODUCTION Bar Code devices provide an accurate, easy, and fast method of data entry and data storage for computerized information systems. The products we are offering now can be integrated into any host computer system by the following ways: Keyboard emulation Wand emulation RS-232C serial asynchronous Dual RS-232C RS-422 RS-485 Parallel OCIA OTHERS All the operating parameters are programmed by bar code programming menu and stored in non-volatile RAM which can
Resumen del contenido incluido en la página 6
-1- FLOW CHART START OF CONFIGURATION SELECT INTERFACES SELECT SYMBOLOGIES OPERATION PARAMETERS SET FACTORY DEFAULTS ** ABORT CONFIGURATION * END OF CONFIGURATION **
SHOW VERSION * Reject new settings & end. ** Accept new settings & end.
Resumen del contenido incluido en la página 7
INTERFACES - 2 - KEYBOARD RS232C CCD WAND EMULATION {OCIA} RESERVED 1 RESERVED 2 To choose an Interface, e.g. KEYBOARD: 1. Scan START OF CONFIGURATION 2. Scan KEYBOARD 3. Scan END OF CONFIGURATION
Resumen del contenido incluido en la página 8
- 3 - SYMBOLOGIES CODE 39 OFF ON INTERLEAVED 2 OF 5 OFF ON STANDARD 2 OF 5 OFF ON MATRIX 2 OF 5 OFF ON CODABAR OFF ON
Resumen del contenido incluido en la página 9
SYMBOLOGIES - 4 - EAN-8 OFF ON EAN-13/UPC-A OFF ON UPC-E OFF ON ISBN/ISSN OFF ON EAN/UPC ADDON 2/5 OFF ON
Resumen del contenido incluido en la página 10
- 5 - SYMBOLOGIES CODE 128 OFF ON CODE 93 OFF ON CHINESE 2 OF 5 OFF ON {MSI/PLESSEY} OFF ON {CODE 11} OFF ON
Resumen del contenido incluido en la página 11
SYMBOLOGIES- 6 - {PHARMACEUTICAL CODE} OFF ON {CODE IV} OFF ON {CODE49} OFF ON Itallian PharmaCode “A” OFF ON EAN-8 TO EAN-13 OFF ON In order to enable Italian PhamaCode, PHARMACEUTICAL CODE should also be enabled.
Resumen del contenido incluido en la página 12
- 7 - CODE 39 TYPE STANDARD FULL ASCII TRANSMIT START/STOP CHAR OFF ON VERIFY CHECKSUN OFF ON TRANSMIT CHECK CHAR OFF ON CODE39 LABEL ID OFF ON
Resumen del contenido incluido en la página 13
CODABAR/NW7 - 8 - TRANSMIT START/STOP OFF ON TYPE OF START/STOP ABCD/ABCD ABCD/TN E abcd/abcd abcd/tn e TRANSMIT CHECK DIGIT OFF ON VERIFY CHECK DIGIT OFF ON
Resumen del contenido incluido en la página 14
- 9 -INTERLEAVED 2 OF 5 BAR CODE LENGTH MINI. TO MAXI. = ? <6-32> MINI.=2. MAXI.=32 CUSTOM DEFINE 3 SETS AVAILABLE TRANSMIT CHECK DIGIT OFF ON VERIFY CHECK DIGIT OFF ON
Resumen del contenido incluido en la página 15
INTERLEAVED 2 OF 5- 10 - To choose BAR CODE LENGTH, e.g. 10 - 20, (0A,14 in Hex): 1. Scan START OF CONFIGURATION 2. Scan BAR CODE LENGTH 3. Scan 0 A 1 4 SET 4. Scan END OF CONFIGURATION CUSTOM DEFINE, user may choose 1 to 3 individual lengths, excluding the range between, e.g. user wants lengths of 12, 16 and 20: (0C, 10 and 14 in Hex) Use above example except: No. 2. Scan CUSTOM DEFINE No. 3. Scan 0 C 1 0 1 4 SET
Resumen del contenido incluido en la página 16
- 11 -STANDARD 2 OF 5 BAR CODE LENGTH MINI. TO MAXI. = ? <6-32> MINI.=2. MAXI.=32 CUSTOM DEFINE 3 SETS AVAILABLE TRANSMIT CHECK DIGIT OFF ON VERIFY CHECK DIGIT OFF ON See example on page 10
Resumen del contenido incluido en la página 17
MATRIX 2 OF 5- 12 - BAR CODE LENGTH MINI. TO MAXI. = ? <6-32> MINI.=2. MAXI.=32 CUSTOM DEFINE 3 SETS AVAILABLE TRANSMIT CHECK DIGIT OFF ON VERIFY CHECK DIGIT OFF ON See example on page 10
Resumen del contenido incluido en la página 18
- 13 - EAN-13/EAN-8 EAN-13 TRUNCATE LEADING DIGIT S = ? 0 TRANSMIT CHECK DIGIT YES NO EAN-8 TRUNCATE LEADING DIGIT S = ? 0 TRANSMIT CHECK DIGIT YES NO Example: user wants to truncate 1 (the first leading digit): 1. Scan START OF CONFIGURATION 2. Scan TRUNCATE LEADING DIGIT 3. Scan 0 1 SET 4. Scan END OF CONFIGURATION
Resumen del contenido incluido en la página 19
UPC-A/UPC-E - 14 - UPC-A TRUNCATE LEADING DIGIT S = ? 0 TRANSMIT CHECK DIGIT YES NO UPC-E TRUNCATE LEADING DIGIT S = ? 0 TRANSMIT CHECK DIGIT YES NO UPC-E TO UPC-A YES NO See example on page 13
Resumen del contenido incluido en la página 20
- 15 - CHINESE 2 OF 5 BAR CODE LENGTH MINI. TO MAXI. = ? <6-32> MINI.=2. MAXI.=32 CUSTOM DEFINE 3 SETS AVAILABLE TRANSMIT CHECK DIGIT OFF ON VERIFY CHECK DIGIT OFF ON See example on page 10