Resumen del contenido incluido en la página 1
Intelligent Pressure Scanner
User’s Manual
(Models 9016, 9021, 9022)
th
13 Edition
September 2007
NetScanner™ System
Visit us on the web:
www.PressureSystems.com
Resumen del contenido incluido en la página 2
Pressure Systems, Inc. NetScanner™ System (9016, 9021, & 9022) User’s Manual ©This User’s Manual is a copyright product of Pressure Systems, Inc. , 2007. Permission is hereby granted to make copies and distribute verbatim copies of this manual, provided the copyright notice and this permission notice are preserved on all copies. - i - www.PressureSystems.com
Resumen del contenido incluido en la página 3
Pressure Systems, Inc. NetScanner™ System (9016, 9021, & 9022) User’s Manual REVISION REVISION HISTORY PRINT DATE 1 Original - 2nd Edition 4/94 2 3rd Edition (add Model 902x and 9016) 11/97 3 4th Edition 3/98 4 5th Edition 9/99 th 5 6 Edition 03/00 th 6 7 Edition (delete Optomux references and add 02/01 multi-point calibration procedures) (add infor- mation about the 9021R- ruggedized version) th 7 8 Edition (officially change name from 9021R 03/02 to 9022, a new ruggedized version of the 9021)
Resumen del contenido incluido en la página 4
Pressure Systems, Inc. NetScanner™ System (9016, 9021, & 9022) User’s Manual Preface This manual describes the NetScanner System Intelligent Pressure Scanner modules (Models 9016, 9021, and 9022). It does not cover the 98RK Scanner Interface Rack, model 9816 Intelligent Pressure Scanner, nor models 903x (Pressure Standards/Controllers) and the 9116 Intelligent Pressure Scanner. These products are covered in their individual User’s Manuals. This manual is divided into seven (7) chapters and seve
Resumen del contenido incluido en la página 5
Pressure Systems, Inc. NetScanner™ System (9016, 9021, & 9022) User’s Manual Our Company Pressure Systems Incorporated, (PSI) develops, manufactures, and services level and pressure measuring instruments where the highest level of traceable accuracy is required for aerospace, industrial, municipal, and environmental applications. Our products have become the world standard for electronic level and pressure measurement and scanning. We are committed to the highest quality design, manufacture,
Resumen del contenido incluido en la página 6
Pressure Systems, Inc. NetScanner™ System (9016, 9021, & 9022) User’s Manual ATTN: PSI REPAIR DEPARTMENT (7-digit RMA number) Pressure Systems, Inc. 34 Research Drive Hampton, Virginia 23666 PSI will return warranty items prepaid via UPS GROUND. If the customer desires another method of return shipment, PSI will prepay and add the shipping charges to the repair bill. Incoming freight charges are the customer’s responsibility. The customer is also responsible for paying shipping charges to and
Resumen del contenido incluido en la página 7
Pressure Systems, Inc. NetScanner™ System (9016, 9021, & 9022) User’s Manual Table of Contents Chapter 1 — General Information ....................................... 1-1 1.1 Introduction .................................................... 1-1 1.2 Description of Instruments ......................................... 1-3 1.3 Options ........................................................ 1-4 1.3.1 Pressure Ranges ........................................... 1-4 1.3.2 Manifolds and Pressure Connec
Resumen del contenido incluido en la página 8
Pressure Systems, Inc. NetScanner™ System (9016, 9021, & 9022) User’s Manual Table of Contents (Cont.) 3.1.2 Commands ............................................... 3-2 3.1.2.1 General Command Format ............................. 3-2 3.1.2.2 Command Field ..................................... 3-3 3.1.2.3 Position Field ....................................... 3-3 3.1.2.4 Datum Fields ....................................... 3-4 3.1.2.5 Format Field ........................................ 3-4 3.1
Resumen del contenido incluido en la página 9
Pressure Systems, Inc. NetScanner™ System (9016, 9021, & 9022) User’s Manual Table of Contents (Cont.) 3.3 Obsolete Commands ............................................ 3-73 Chapter 4 — Calibration ............................................... 4-1 4.1 Introduction .................................................... 4-1 4.2 Re-zero Calibration .............................................. 4-3 4.2.1 Re-zero Calibration Valve Control ............................ 4-3 4.2.2 Re-zero Calibration S
Resumen del contenido incluido en la página 10
Pressure Systems, Inc. NetScanner™ System (9016, 9021, & 9022) User’s Manual Table of Contents (Cont.) 5.1.6 Replacement of O-Rings ................................... 5-10 5.1.6.1 DH200 Pressure Transducer O-Ring Replacement ......... 5-11 5.1.6.2 Tubing Plate O-Ring Replacement ..................... 5-12 5.1.6.3 Adapter Plate O-Ring Replacement ..................... 5-13 5.1.6.4 Calibration Manifold Piston O-Ring Replacement ......... 5-14 5.1.6.5 Solenoid Valve O-Ring Replacement ............
Resumen del contenido incluido en la página 11
Pressure Systems, Inc. NetScanner™ System (9016, 9021, & 9022) User’s Manual List of Figures Figure 1.1 NetScanner System Pneumatic Intelligent Pressure Scanners ........ 1-2 Figure 2.1 9016, 9021, 9022 Power Pin Assignments ...................... 2-2 Figure 2.3 Ethernet Host Port Connector Pins ............................ 2-3 Figure 2.3 Ethernet Network Topology .................................. 2-5 Figure 2.4 9021 Transducer Wiring ................................... 2-10 Figure 2.4a 9022 Tr
Resumen del contenido incluido en la página 12
Pressure Systems, Inc. NetScanner™ System (9016, 9021, & 9022) User’s Manual Chapter 1 General Information 1.1 Introduction This User’s Manual will: ™ ! Explain the electrical and pneumatic pressure connections for the NetScanner System Models 9016, 9021, and 9022 Intelligent Pressure Scanners. ! Instruct you on how to program each module with computer software. ! Instruct you on using the PSI start-up software to mani
Resumen del contenido incluido en la página 13
Pressure Systems, Inc. NetScanner™ System (9016, 9021, & 9022) User’s Manual NOTE: The newest PSI Intelligent Pressure Scanner is the 9022. Its serial numbers begin with 1000. The 9022 is similar in function to the 9021 (using external sensors), however, the 9022 features circular (military style connectors), splash-proof case and connectors, antialiasing filters, and a jumper selectable precision 5 or 10 volt excitation voltage for use with third-party sensors. The overall dimensions of the 90
Resumen del contenido incluido en la página 14
Pressure Systems, Inc. NetScanner™ System (9016, 9021, & 9022) User’s Manual 1.2 Description of Instruments ™ NetScanner System family of Intelligent Pressure Scanner modules are flexible pressure measuring devices intended for use in test and production environments. Models are available with 12 (Model 9021/9022), or 16 (Model 9016) channels, each with individual pneumatic or all- media transducers per channel. The most distinctive features are highlighted below: ! Pre-calibrated Transducer —
Resumen del contenido incluido en la página 15
Pressure Systems, Inc. NetScanner™ System (9016, 9021, & 9022) User’s Manual ! Measurement flexibility — each 9021/9022 module is capable of measuring general purpose voltage signals on any channel not populated with a 9400-type transducer. Full-scale ranges of ±50, ±100, ±250 and ±4500 mV are supported through programmable gain amplifier circuitry. ! Ease of use — modules have simple command sets and provide engineering units output. They may interface directly to a desktop or laptop compu
Resumen del contenido incluido en la página 16
Pressure Systems, Inc. NetScanner™ System (9016, 9021, & 9022) User’s Manual utilize an SAE 5/16 - 24 O-ring boss which supports a variety of other adapter compression fittings. They are also available with a quick disconnect plate which contains 0.063" bulge tubulation. The common differential version is available with all choices of fittings. The true differential version is available with 0.063" bulged tubulation fittings only. Models 9021 and 9022 12-channel Intelligent Pressure Scanners
Resumen del contenido incluido en la página 17
Pressure Systems, Inc. NetScanner™ System (9016, 9021, & 9022) User’s Manual This page intentionally left blank 1 - 6 www.PressureSystems.com
Resumen del contenido incluido en la página 18
Pressure Systems, Inc. NetScanner™ System (9016, 9021, & 9022) User’s Manual Chapter 2 Installation and Set Up 2.1 Unpacking and Inspection ™ The NetScanner System product family has many components which may be purchased either as an entire system, or as individual pieces of equipment. Before assembling the system, use the shipping bill as a reference to ensure that all parts have arrived. Pressure Systems takes no responsibility for equipment that is damaged during shipment. If containers
Resumen del contenido incluido en la página 19
Pressure Systems, Inc. NetScanner™ System (9016, 9021, & 9022) User’s Manual 2.3 Preparation for Use 2.3.1 Environment All standard Intelligent Pressure Scanners are factory calibrated to be accurate over a specified ™ temperature range, but may be operated or stored over a wider temperature range (see NetScanner System Data Sheet, published separately). Operating or storing an instrument outside its specified range(s) will result in a loss of measurement accuracy and may cause permanent damag
Resumen del contenido incluido en la página 20
Pressure Systems, Inc. NetScanner™ System (9016, 9021, & 9022) User’s Manual 2.3.3 Mounting and Module Dimensions Detailed mechanical drawings for each module are included in Appendix D. 2.3.4 Network Communications Hookup ™ Every NetScanner System Intelligent Pressure Scanner contains a Host Port, allowing it to be interconnected in a network with other modules and a host computer. Models 9016, 9021, and 9022 have an Ethernet Host Port using TCP/IP and UDP/IP transmission protocols. 2.3.4.1 Et