Resumen del contenido incluido en la página 1
User’s Manual
OPT-6125 Series
Handheld CCD Scanner
25-ULGPMU01-01
April 2002
Keyboard Wedge Interface
USB Interface
RS232 Interface
8 Olympic Drive
Orangeburg, NY 10962
Tel 845.365.0090
Fax 845.365.1251
www.opticonUSA.com
Resumen del contenido incluido en la página 2
Resumen del contenido incluido en la página 3
Manual No. 25-ULGPMU01-01 Series OPT Handheld CCD Scanner Table of Contents PART I CCD Scanning Part III Bar Code Menu Functions Section A Programming the Scanner……………..12 General Information ...........................................4 Unpacking Section B Symbology Selections ..................... 13 Factory Technical Support Enabling only a single symbology...................... 13 Enabling an addition symbology.............
Resumen del contenido incluido en la página 4
Manual No. 25-ULGPMU01-01 Series OPT Handheld CCD Scanner Part I General Information The OPT-6125 Series CCD Scanners utilize state-of-the-art imaging technology similar to that found in digital cameras, facsimile machines and video camcorders. The scanner images the bar code label, then converts the digital signals into data the host computer can understand. By capturing the bar code image all at once, the scanner provides fas
Resumen del contenido incluido en la página 5
Manual No. 25-ULGPMU01-01 Series OPT Handheld CCD Scanner Part II Installation and SetUp This section of the manual contains information on the physical installation of the scanner as well as certain programming options. There is a separate section for each type of interface. Check to see which type of interface your scanner has and turn to that section for information on installing the scanner A.) Installation – Keyboard Wedge
Resumen del contenido incluido en la página 6
Manual No. 25-ULGPMU01-01 Series OPT Handheld CCD Scanner Reset All Defaults – Keyboad Wedge Interface Our scanners are shipped with factory default settings that represent the settings most commonly used by our customers. In most applications, the scanner will work right out of the box without any need for additional programming. At any time you can return the scanner to the factory default settings by scanning the “Reset all De
Resumen del contenido incluido en la página 7
Manual No. 25-ULGPMU01-01 Series OPT Handheld CCD Scanner Intercharacter Delay for Keyboard Wedge interface The scanner may send data faster than the computer or application program can accept. This is called "keyboard buffer overrun". If data appears to be missing, random read errors occur or the scanner locks up and will not scan, experiment with the various keyboard timing options listed in the menu to follow. Start Program
Resumen del contenido incluido en la página 8
Manual No. 25-ULGPMU01-01 Series OPT Handheld CCD Scanner B.) Installation – RS232 Interface The RS-232 scanner cable is terminated in with a DB9 female connector. An external power supply (+5V DC) may be necessary. There is a power supply jack on the RS-232 connector. Installation is as follows: 1. Plug the scanner into an RS232 serial port (such as COM1) of the host PC. If external power is required, insert external power pl
Resumen del contenido incluido en la página 9
Manual No. 25-ULGPMU01-01 Series OPT Handheld CCD Scanner RS-232C Communication Parameters Handshaking Protocol Start Program ZZ -[[- Menu None P0 -Q1- Β RTS/CTS HP04 +IQ15+ ACK/NAK P3 -Q!- Xon/Xoff ZG -[H- Flow Control I0 Time -J1- Β Unlimited Flow Control: I1 -J2- 100ms Flow Control: I2 -J3- 200ms Flow Control: I3 -J!- 400ms Baud Rate 19200 K7 -L8- 9600 K6 -L7- Β 4800 K5 -L6- 2400 K4 -L5- 1200 K3 -L!- 600 K2 -L3- Page 9
Resumen del contenido incluido en la página 10
Manual No. 25-ULGPMU01-01 Series OPT Handheld CCD Scanner Data Bits / Stop Bits / Parity 7 Data Bits L0 -M1- 8 Data Bits L1 -M2- Β 1 Stop Bit L5 -M6- Β 2 Stop Bits L6 -M7- Even L3 Parity -M!- Odd L4 Parity -M5- Mark L2 No Parity -M3- Β End Program ZZ ,ZZ, Menu Page 10
Resumen del contenido incluido en la página 11
Manual No. 25-ULGPMU01-01 Series OPT Handheld CCD Scanner C.) Installation – USB Interface Plug the scanner into the USB connector on your host computer. PC must be running Windows 98 or higher or iMac Rev A or higher. The computer will sense the presence of the scanner and load any required software drivers automatically. Reset All Defaults - USB Interface Our scanners are shipped with factory default settings that represent
Resumen del contenido incluido en la página 12
Manual No. 25-ULGPMU01-01 Series OPT Handheld CCD Scanner Part III Bar Code Menu Functions Section A Programming the Scanner This manual contains information that allows you to easily change certain programmable parameters of the scanner. The scanner is ready to use - no additional programming is required in most situations. The scanner has been programmed at the factory with the most common settings. These factory default setti
Resumen del contenido incluido en la página 13
Manual No. 25-ULGPMU01-01 Series OPT Handheld CCD Scanner Symbology Selection Start/End Program ZZ -[[- Menu Read all codes A0 -B1- Β Code 39 A2 only -B3- Codabar A3 only -B!- IATA only A4 -B5- Code 93 A5 only -B6- Code 128 A6 only -B7- MSI/Plessey A7 only -B8- Telepen A9 only -B:- Matrix 2of5 AB only -BC- All UPC and J0 EAN only -K1- UPC J1 only -K2- CONTINUED ON NEXT PAGE... Page 13
Resumen del contenido incluido en la página 14
Manual No. 25-ULGPMU01-01 Series OPT Handheld CCD Scanner Symbology Selection (continued) Start/End Program ZZ -[[- Menu UPC+2 J2 only -K3- UPC+5 J3 only -K!- EAN J4 only -K5- EAN+2 J5 only -K6- EAN+5 J6 only -K7- Industrial 2of5 J7 -K8- only Interleaved 2of5 J8 -K9- only Trioptics JD only -KE- These options do not influence the reading of the menu labels. The required bar code types can be selected by enabling a single readable
Resumen del contenido incluido en la página 15
Manual No. 25-ULGPMU01-01 Series OPT Handheld CCD Scanner Symbology Additions If scanner will not be used to read all symbologies (default setting), speed operation by using this menu to add only the specific symbologies being used (add only the symbologies that are required). Start/End Program ZZ -[[- Menu Disable all B0 -C1- Enable B2 Code 39 -C3- Enable B3 Codabar -C!- Enable B4 IATA -C5- Enable B5 Code 93 -C6- Enable B6 Code
Resumen del contenido incluido en la página 16
Manual No. 25-ULGPMU01-01 Series OPT Handheld CCD Scanner Symbology Additions (continued) Start/End Program ZZ -[[- Menu Enable R4 EAN -S5- Enable R5 EAN+2 -S6- Enable R6 EAN+5 -S7- Enable Industrial R7 -S8- 2of5 Enable Interleaved R8 -S9- 2of5 Page 16
Resumen del contenido incluido en la página 17
Manual No. 25-ULGPMU01-01 Series OPT Handheld CCD Scanner Setting the Number of Characters to be Scanned Start/End Program ZZ -[[- Menu Fixed length OFF H0 all codes -I1- Β Fixed length ON H1 -I2- all codes Fixed length ON HK selected codes -IL- Min. length HL selected codes -IM- Max. length HM selected codes -IN- Setting Code Specific Options - Options for specific codes may be configured affecting: * Enabling and disabling c
Resumen del contenido incluido en la página 18
Manual No. 25-ULGPMU01-01 Series OPT Handheld CCD Scanner UPC Settings Options for UPC-A and UPC-E bar codes. NOTE: Abbreviations: Xmit = transmit; CD = Check digit; CC = Country code Start/End ZZ Program -[[- Menu UPC-A as EAN13 E2 w/ CD -F3- (13 digits) UPC-A w/ CD E3 -F!- (12 digits) UPC-A w/ CD E4 (12 digits) -F5- UPC-A w/o CD E5 -F6- (11 digits) UPC-E w/ CC & CD E6 -F7- (8 digits) UPC-E w/o CC, E7 w/ CD -F8- (7 digits) U
Resumen del contenido incluido en la página 19
Manual No. 25-ULGPMU01-01 Series OPT Handheld CCD Scanner UPC Settings (continued) Options for UPC-A - The UPC-A symbology is a fixed length symbology encoding 11 data digits, a check digit and non printable start/stop characters. Supported characters are numeric digits 1 to 9. An optional leading zero can be transmitted which, together with the data and the check digit, forms a 13 digit field providing compatibility with the EAN
Resumen del contenido incluido en la página 20
Manual No. 25-ULGPMU01-01 Series OPT Handheld CCD Scanner EAN-13 and EAN-8 Settings Start/End Program ZZ -[[- Menu EAN-13 6K transmit CD -7L- EAN-13 do not 6J -7K- transmit CD EAN-8 6I transmit CD -7J- EAN-8 do not 6H -7I- transmit CD Disable ISBN IB -JC- translation Enable ISBN IA translation -JB- Enable ISBN if IK -JL- possible Disable ISSN HN translation -IO- Β Enable ISSN HO -IP- translation Enable ISSN if 4V pos