Resumen del contenido incluido en la página 1
®
Magellan 1400i
Omni-Directional Imaging Scanner
Product Reference Guide
Resumen del contenido incluido en la página 2
Datalogic Scanning, Inc. 959 Terry Street Eugene, Oregon 97402 Telephone: (541) 683-5700 Fax: (541) 345-7140 An Unpublished Work - All rights reserved. No part of the contents of this documentation or the procedures described therein may be reproduced or transmitted in any form or by any means without prior written permission of Datalogic Scanning, Inc. or its subsidiaries or affiliates ("Datalogic" or “Datalogic Scanning”). Owners of Datalogic products are hereby granted a non-exclusive, re
Resumen del contenido incluido en la página 3
Table of Contents About This Manual ............................................................................................................... 1-1 Manual Conventions ....................................................................................................... 1-1 Connecting the Scanner ....................................................................................................... 1-2 Programming ..............................................................................
Resumen del contenido incluido en la página 4
Minimum Reads .............................................................................................................5-7 GTIN ............................................................................................................................5-8 Expand UPC/EAN to GTIN ................................................................................................5-8 EAN-13 ..............................................................................................................
Resumen del contenido incluido en la página 5
Interleaved 2 of 5 Length 1, Length 2 Programming Instructions .........................................5-43 Interleaved 2 of 5 Stitching ............................................................................................5-44 Minimum Reads ............................................................................................................5-45 Codabar ............................................................................................................................5-46 D
Resumen del contenido incluido en la página 6
Keyboard Wedge ............................................................................................................B-2 Standard Feature Defaults ................................................................................................... D-1 Keyboard Model Cross Reference ...........................................................................................E-1 Accepting RS-232 Commands ...........................................................................................
Resumen del contenido incluido en la página 7
Chapter 1 Getting Started ® The Magellan 1400i Omni-Directional Imaging Scanner offers hands-free scanning for small, easily handled items and handheld scanning for bulkier items. Its aggressive imaging perfor- mance and intuitive operation reduces user training and speeds checkout for better customer service. About This Manual This manual presents advanced user information which includes connection, programming, product and cable specifications, and other useful references. For additional in
Resumen del contenido incluido en la página 8
K e W y e b d o a g r d e Getting Started Connecting the Scanner The scanner kit you ordered to match your interface should provide a compatible cable for your installation. Use the appropriate instructions below to connect the scanner to the terminal, PC or other host device. Upon completing the connection via the appropriate interface instructions below, proceed to the Interface Related Features section of this manual and scan the bar code to select the correct interface type. RS-232 Seri
Resumen del contenido incluido en la página 9
Programming Wand Emulation Connection — Connect the scanner to the appropriate port on the termi- 1 nal/PC via a decoder using the correct cable for the interface type you ordered. Reference Figure 2. IBM Connection — Connect the scanner to the IBM port on the terminal/PC using the cor- rect IBM cable. Reference Figure 2. Keyboard Wedge Connection — Before connection, turn off power to the terminal/PC. The Keyboard Wedge cable has a ‘Y’ connection from the scanner. Connect the female to the m
Resumen del contenido incluido en la página 10
Getting Started LED and Beeper Indicators The scanner’s beeper sounds and its green LED illuminates to indicate various functions or errors on the scanner. The tables below list these indications. One exception to the behaviors listed in the tables is that the scanner’s functions are programmable, and may or may not be turned on. For example, certain indications, such as the power-up beep can be disabled using programming bar code labels. Green LED Indications LED INDICATION COMMENT INDIC
Resumen del contenido incluido en la página 11
Error Codes Error Codes Upon startup, if the scanner flashes its indicator LED or sounds an unexpected series of beep tones (other than normal power-up indications), this means the scanner has not passed its auto- 1 matic Selftest and has entered FRU isolation mode. If the scanner is reset or the button is pressed, the sequence will be repeated. The following table describes the LED flashes/beep codes associated with an error found. NUMBER OF LED FLASHES/ ERROR CORRECTIVE ACTION BEEPS 1 Conf
Resumen del contenido incluido en la página 12
Getting Started NOTES ® 1-6 Magellan 1400i
Resumen del contenido incluido en la página 13
Chapter 2 General Features Double Read Timeout The Double Read Timeout feature sets a time limit that determines how much time must pass before reading the same label again (e.g. two identical items in succession). START / END PROGRAMMING BAR CODES 0.1 Second 0.2 Second 0.3 Second 0.4 Second 0.5 Second 0.6 Second DEFAULT Product Reference Guide 2-1
Resumen del contenido incluido en la página 14
General Features Double Read Timeout — cont. START / END PROGRAMMING BAR CODES 0.7 Second 0.8 Second 0.9 Second 1 Second PDF Double Read Timeout This double read timer value is used ONLY when scanning PDF417 bar codes. NOTE The PDF Double Read Timeout feature sets a time limit that determines how much time must pass before reading the same PDF417 label again (e.g. two identical PDF417 bar codes in suc- cession). START / END PROGRAMMING BAR CODES 1.5 Seconds ® 2-2 Magellan 1400i
Resumen del contenido incluido en la página 15
PDF Double Read Timeout PDF Double Read Timeout — cont. START / END PROGRAMMING BAR CODES 1.6 Seconds 1.8 Seconds DEFAULT 1.9 Seconds 2 Seconds 2.1 Seconds 2.2 Seconds 2.3 Seconds 2.4 Seconds 2.55 Seconds Product Reference Guide 2-3
Resumen del contenido incluido en la página 16
General Features Label Gone Timeout This feature sets the time after the last label segment is seen before the scanner prepares for a new label. START / END PROGRAMMING BAR CODES Sets the label gone timeout duration using hex values from 000 to 255 in increments of ten milliseconds (10ms or 0.01 seconds). To configure this feature, scan the “START/END” bar code above to place the unit in Programming Mode, then the “Set Label Gone Tim- eout,” followed by three digits (zero padded) from the Alph
Resumen del contenido incluido en la página 17
Sleep Mode Sleep Mode This feature specifies the amount of time with no bar code reads before the scanner enters sleep mode. START / END PROGRAMMING BAR CODES 15 Seconds DEFAULT 30 Seconds 1 Minute 2 Minutes 3 Minutes 4 Minutes 5 Minutes Product Reference Guide 2-5
Resumen del contenido incluido en la página 18
General Features Sleep Mode — cont. START / END PROGRAMMING BAR CODES 6 Minutes 7 Minutes 8 Minutes 9 Minutes 10 Minutes DEFAULT 12 Minutes 15 Minutes 30 Minutes 1 Hour ® 2-6 Magellan 1400i
Resumen del contenido incluido en la página 19
LED and Beeper Indicators LED and Beeper Indicators Power On Alert Disables or enables the indication (a single beep) that the scanner has finished all its power up tests and is now ready for operation. START / END PROGRAMMING BAR CODES Disable Enable DEFAULT Product Reference Guide 2-7
Resumen del contenido incluido en la página 20
General Features Good Read: When to Indicate This feature specifies when the scanner will provide indication (beep and/or flash its green LED) upon successfully reading a bar code. Choices are: • Good Read = Indicate after decode • Good Read = Indicate after transmit • Good Read = Indicate after CTS goes inactive, then active This option (Indicate after CTS goes inactive, then active), which uses CTS, is only valid for RS-232 inter- faces. NOTE START / END PROGRAMMING BAR CODES After Decode DEF