Resumen del contenido incluido en la página 1
P
PNEUMATIC TOOLS
Operating and Maintenance Manual
403606-10
08/02
Resumen del contenido incluido en la página 2
PASLODE MODEL NUMBER DESIGNATION The model number of each Paslode tool contains information about the tool and the fasteners that are used with it. The following example illustrates the information contained in this tool model number. / 00 O 000 C P NAILER Power Pack Tool application letter Type of tool ( C = coil nailer) ( S = strip nailer) ( F = finish nailer) Maximum fastener ( R = Roof nailer) length, in inches that can be used with the tool Maximum fastener length in millimeters STAPLER 00
Resumen del contenido incluido en la página 3
INTRODUCTION Congratulations on purchasing a Paslode pnuematic tool. You have made a wise choice. A Paslode tool is a professional quality tool that combines power and speed in a light weight design for versatile operation in a variety of industial and construction applications. Please take the time to review this entire manual and all other documentation that came with the tool. They will help you to become familiar with operating a power fastening tool. Be sure to read the safety instruction
Resumen del contenido incluido en la página 4
SAFETY INSTRUCTIONS in use or when you leave the work area. The tool SAFETY FIRST should never be left unattended because people who These safety instructions provide information necessary are not familiar with the tool might handle it and ® for safe operation of Paslode tools. DO NOT ATTEMPT injure themselves or others. TO OPERATE THE TOOL UNTIL YOU READ AND UNDERSTAND ALL SAFETY PRECAUTIONS AND CARRY THE TOOL ONLY BY THE HANDLE MANUAL INSTRUCTIONS. Always carry the tool by the handle only.
Resumen del contenido incluido en la página 5
AIR SYSTEMS For air-powered tools to work their best, the air • Air hoses are not longer than 150 feet. supply system must be properly installed and maintained regularly. A drawing in this section shows a properly installed air supply system. • The air system is lubricated regularly. Handy checklists for installing and maintaining air supply systems follow. • A regular maintenance program is followed. Indoor Air System Installation -Be certain that: Filter/Regulator/Lubricator Units • All pipe
Resumen del contenido incluido en la página 6
AIR SYSTEMS - Continued Calculated Required Piping Calculating Compressor Size Use the air consumption chart in the Tool Schematic for each tool when calculating the For example, given a 20 hp electric compressor operating requirements for the tools. Paslode supplying approximately 80 cfm of air at 120 psi tools are designed to operate efficiently and a main supply pipe length of 350 feet, we see between 80 and 120 psi and should never be by the table the minimum main pipe inside diam- operate
Resumen del contenido incluido en la página 7
TOOL INSTALLATION TOOL OPERATION Depth of Drive Adjustment (On tools equipped with this feature) Your Paslode tool comes ready for immediate use and can be installed by following these steps: 1. SAFETY - All tool operators and their immediate supervisors must become familiar with the operator safety instructions before operating the tool. The instructions are on page 2 of this manual. The depth of drive adjustment is made by adjusting the work contacting element. The 2. Included wuth each t
Resumen del contenido incluido en la página 8
TOOL OPERATION - TOOL LOADING continued Staplers ➔ Step No. 1 – Pull back the rail follower until it MOVE UP latches at the end of the magazine. The rail cover TO INCREASE DRIVE DEPTH will automatically open. MOVE DOWN TO DECREASE DRIVE DEPTH ➔ SOCKET HEAD CAPSCREW WORK CONTACTING ELEMENT Precision Placement Driving ■ Grasp the tool handle firmly and hold the bottom of the work contacting element firmly against the workpiece until it is com- pletely depressed. Step No. 2 – Insert the fastener
Resumen del contenido incluido en la página 9
Coil Nailers Step No. 3 – Remove the retainer from a nail coil and Step No. 1 – Grasp the nailer handle firmly with one place the nail coil in the magazine with the tips of the nails hand and with the other hand unlatch the magazine against the loading tray and with about 4 inches of coil cover clip. Swing the magazine door open. unwound. Step No. 4 - Slide the free strip of nails along the top of the feeder body assembly and place the first nail between the feed claw and the locator. Step No.
Resumen del contenido incluido en la página 10
PowerMaster Plus T250-F16 Series Finish Nailer Series Strip Nailer Step No. 1 – Grasp the nailer firmly with one hand. Step No. 1 – Grasp the nailer handle firmly. Pull the magazine follower all the way to the rear of the magazine until it is latched into its loading position by the magazine latch. Step No. 2 – Insert the strip with the point of the fastener facing down towards the bottom of the magazine. Step No. 2 – Insert the a strip of fasteners into the top of the magazine with the point
Resumen del contenido incluido en la página 11
2000 Series Stapler 6000 Series Strip Nailer Step No. 1 – Grasp the stapler firmly with one hand. Step No. 1 – Grasp the nailer handle firmly. Pull the Depending on the model,either squeeze the latch magazine follower all the way to the rear of the with your small finger or press it with your thumb magazine and pivot it downward until it latches into With your other hand, pull the magazine back the locked position. towards you. Step No. 2 – Insert the a strip of fasteners into the top of the ma
Resumen del contenido incluido en la página 12
■ Open the drain on the air compressor tank to drain any MAINTENANCE moisture at least daily in extremely cold or humid weather. A few ounces of anti-freeze in the tank will keep the air ® free of frost. Paslode tools are built for ease of maintenance. A few simple details will assure trouble-free operation and long tool life. Anyone who uses or maintains the tool must read Testing the Tool After Servicing the safety and maintenance instructions. Study the sche- After replacing any part or pa
Resumen del contenido incluido en la página 13
MAINTENANCE - Continued MAINTENANCE TABLE ACTION WHY HOW Drain air line filter(daily). Prevent accumulation of Open manual petcock (most mositure and dirt. air supply systems have such a valve). Keep lubricator filled. Keep tool lubricated. Fill with Paslode pneumatic tool lubricant. Part No. 219026. Clean filter element-then blow Prevent clogging of filter with Wash with soap and water or air through filter in direction dirt. follow manufacturers instruc- opposite to normal flow. tions. Check t
Resumen del contenido incluido en la página 14
OPERATOR TROUBLESHOOTING PROBLEM CORRECTIVE ACTION Adjust work contacting element (retract length). Fasteners will not drive completely into wood. Increase air pressure (do not exceed 120 psi). Increase air flow to tool -- use larger air lines Fasteners penetrate properly during normal (3/8 inch ID minimum). operation, but won't drive fully at faster speeds. Adjust work contacting element (extend length). Fasteners drive too deeply into wood. Reduce air pressure. Op
Resumen del contenido incluido en la página 15
TOOL WARRANTY P An Illinois Tool Works Company 888 Forest Edge Drive Vernon Hills, Illinois 60061 TOOL WARRANTY AND LIMITATIONS 15