Resumen del contenido incluido en la página 1
1250/1750/2750 Manual 3/6/02 2:45 PM Page 1
OWNER’S MANUAL
1000/2000 WATT
SERIES
THE WHISTLER GROUP HIGH SURGE POWER INVERTERS
CORPORATE HEADQUARTERS
13016 N. Walton Blvd.
Bentonville, AR 72712
TEL (479) 273-6012 FX (479) 273-2927
www.whistlergroup.com
PRODUCT DEVELOPMENT CENTER
25 Industrial Ave.
Chelmsford, MA 01824
TEL (978) 244-1400 FX (978) 244-1491
CUSTOMER RETURN CENTER
1201 N. Dixieland Rd.
Rogers, AR 72756
Consumer Relations Tel (800) 531-0004
See important information section r
Resumen del contenido incluido en la página 2
1250/1750/2750 Manual 3/6/02 2:45 PM Page 3 INTRODUCTION If you have questions concerning the Dear Whistler Owner, operation of this Whistler product For many of us, a vehicle is more than just transportation. It please call consumer relations: can be a mobile office, communications or enter t a i n m e n t c e n t e r, or simply an expression of our personality. Whistler p roducts are designed to make the time you spend in your 1-800-531-0004 vehicle more productive, more fulfilling, safer,
Resumen del contenido incluido en la página 3
1250/1750/2750 Manual 3/6/02 2:45 PM Page 5 TABLE OF CONTENTS WHISTLER FEATURES A Word About Whistler Power Inverters Topic Page Features Summary ..................................................................3-7 Whistler inverters convert low voltage, direct current (DC) Important Information................................................................8 to 110 volt alternating household current (AC). The AC output is called “modified sine wave”. See “Technical Inverter Information.
Resumen del contenido incluido en la página 4
1250/1750/2750 Manual 3/6/02 2:45 PM Page 7 FEATURES FEATURES for safe operation. When this occurs, turn the equipment automatically shut down. In this event, it is likely that the or appliance off. draw of the equipment or appliance being operated is In the event of excess temperature, the High Speed greater than the battery is capable of producing. Cooling Fan also will automatically turn on. Overheating may result when the inverter is being operated at levels Voltage Indicator. This Bar Gr
Resumen del contenido incluido en la página 5
1250/1750/2750 Manual 3/6/02 2:45 PM Page 9 FEATURES FEATURES Note: e). Two Standard North American 110 AC Outlets are The 2000 series inverters incorporates all of the operating provided. and safety features of the 1000 series models. In addition to these common features, the 2000 series are equipped f).Remote Operation Socket. with circuit breakers and a terminal for making direct con- The inverter is designed to be nection between the inverter and an electrical distribution operated from a
Resumen del contenido incluido en la página 6
1250/1750/2750 Manual 3/6/02 2:45 PM Page 11 IMPORTANT INFORMATION INVERTER INFORMATION Getting Star t e d I m p o rtant Information About Your New W h i s t l e r Power equipment and appliances which operate with motors Inverter. or tubes r e q u i re an initial surge of power to get them up and This manual will provide you with directions for the safe running. This power surge is r e f e rred to as the "star t i n g and efficient operation of your Whistle Power Inverter. load" or "peak lo
Resumen del contenido incluido en la página 7
1250/1750/2750 Manual 3/6/02 2:45 PM Page 13 INVERTER INFORMATION INVERTER INFORMATION Don’t Push It. designed to shut down automatically in the event of a power overload. Testing appliances and equipment with Although your Whistler power inverter has the capacity to s t a rt up load ratings comparable to your inverter wattage p rovide power output (excess current) equal to appr o x i- rating will not damage it. mately two times its rated wattage capacity for a very brief period, it is design
Resumen del contenido incluido en la página 8
1250/1750/2750 Manual 3/6/02 2:45 PM Page 15 BATTERY/CABLE INFORMATION BATTERY INFORMATION 1. To calculate the amp/hour of the battery, first determ i n e • It may be advisable to operate the inverter from a bank its "r e s e rve minutes" rating. (Deep cycle marine batter- of batteries of the same type in a "parallel" configura- ies generally have the highest r e s e rve minute ratings). tion. Two such batteries will generate twice the This rating typically is marked on the battery along with
Resumen del contenido incluido en la página 9
1250/1750/2750 Manual 3/6/02 2:45 PM Page 17 OPERATION CABLE INFORMATION Making the Connection. R e g a rdless of the wire gauge selected to make the connec- tions to the battery, we recommend use of an "O Ring A d a p t e r." Use of #0 gauge wire to make the connections to 1. Make certain that the Power switch is in the OFF (O) the inverter may r e q u i re a "0 to 4 Gauge Adapter." Both position. adapters are available through electronic supply stor e s 2. Connect the cables to the power in
Resumen del contenido incluido en la página 10
1250/1750/2750 Manual 3/6/02 2:45 PM Page 19 OPERATION OPERATION Note: connecting the ground, make certain that the invert- • Loose connections can result in a severe decrease in er is turned off. Operating the inverter without voltage which may cause damage to the wires and properly grounding it may result in electrical shock. insulation. • Failure to make proper connection between the 7. Turn the inverter ON (I). Check the Bar Graph Meter inverter and the power source will result in on th
Resumen del contenido incluido en la página 11
1250/1750/2750 Manual 3/6/02 2:45 PM Page 21 OPERATION OPERATION appliance or equipment being operated will not signif- b). The 2000 series models are designed for direct wiring to an electrical distribution panel via the direct icantly decrease the power being generated by the inverter. For best operating results, the extension cord wire connection "cut out" on the front panel of the inverter. should be no more than 50 feet long. • Check frequently to ensure that the input and out This dire
Resumen del contenido incluido en la página 12
1250/1750/2750 Manual 3/6/02 2:45 PM Page 23 OPERATION OPERATION 3. Isolate the television, its power cord and antenna cables If you are using the inverter while the engine is off, we f rom the 12 volt power source by running an extension cord recommend you start the engine every 30 to 60 minutes and f rom the inverter to the television set. let it run for at least 10 minutes to r e c h a rge the battery. We also recommend that the device plugged into the inverter be 4. Coil the televisio
Resumen del contenido incluido en la página 13
1250/1750/2750 Manual 3/6/02 2:45 PM Page 25 OPERATION OPERATING PRINCIPALS Some Powerful Advice. • V E N T I L ATION. In order to disperse the heat generat- e d while the inverter is in operation, keep it well venti- Your Whistler i n v e rter will work best when placed on a r e a- lated. While in use, maintain several inches of clear- sonably flat surface. The floor or wall of your vehicle are good ance around the top and sides of the inverter. l o c a t i o n s . • FUMES & GASES. Avoid
Resumen del contenido incluido en la página 14
1250/1750/2750 Manual 3/6/02 2:45 PM Page 27 OPERATING PRINCIPALS OPERATING PRINCIPALS/SUMMARY For more information on inverters see our Inverter FAQ page This stepped waveform is similar to the power generated by at www . w h i s t l e rg ro u p . c o m / f a q - i n v e rt e r s . a s p utilities and has a broad range of applications. The modified sine wave produced by your Whistler Inverter The modified sine wave produced by your Whistler invert e r A true sine wave typical of home AC ou
Resumen del contenido incluido en la página 15
1250/1750/2750 Manual 3/6/02 2:45 PM Page 29 OPERATION SUMMARY OPERATION SUMMARY • If the rated power consumption of the equipment is in the range of the maximum specified wattage of your • When in use, make certain that the inverter is proper- c o n v e rt e r, test the inverter to ensure that it will operate ly ventilated. p ro p e r l y. • Do not use the inverter near flammable materials, • B e f o re attempting to use a battery charger see page 19. fumes, or gases. • B e f o re attempting
Resumen del contenido incluido en la página 16
1250/1750/2750 Manual 3/6/02 2:45 PM Page 31 TROUBLESHOOTING TROUBLESHOOTING Overload or High Temp LED on PROBLEM: TV Interference Problem Solution Problem Solution Equipment has a high Turn inverter power switch start up surge. OFF (O) and then ON (l) Electrical interference from Add a Ferrite data line filter again until the inverter inverter. on to the TV power cord. powers your appliance. This filter is available at Repeat as necessary RadioShack, to get your appliance "started".
Resumen del contenido incluido en la página 17
1250/1750/2750 Manual 3/6/02 2:45 PM Page 33 SPECIFICATION WARRANTY WHISTLER PP1000AC & PP1250AC WATT Consumer W a rr a n t y INVERTER SPECIFICATIONS The Whistler 1000 & 2000 series inverters are warranteed to Maximum Continuous Power………………1000 Watts/1250 Watts the original purchaser for a period of (2) two years, from the Maximum Surge Capability (Peak Power)...2000 Watts/2500 Watts date of original purchase, against all defects in materials and No Load Current Draw……………………………….............<
Resumen del contenido incluido en la página 18
1250/1750/2750 Manual 3/6/02 2:45 PM Page 35 WARRANTY WARRANTY I M P O RT A N T: Whistler will not assume responsibility for loss or damage incurred in shipping. Ther e f o re, please ship your The out of warranty service fee for your PP1250AC Whistler i n v e rter insured with r e t u rn receipt re q u e s t e d . inverter is $135.00, PP1750AC Whistler inverter is $225.00 and PP2750AC Whistler inverter is $465.00. If you require out 2. Include with your unit the following information, clea