Enterprise 1U Rackmount Series User's Manual 1. Introduction 2 2. Controls and Indicators 6 3. Installation 8 4. Operation 12 5. Troubleshooting 15 6. Replacing the Battery 16 7. Obtaining Service 19 8. Specifications 20 9. Configurable Parameters & Settings 22 10. Limited Product Warranty 23 11. Declaration of Conformity 25 © Copyright Para Systems, Inc., 2005 1 English
Resumen del contenido incluido en la página 3
English Thank you for purchasing a MINUTEMAN power protection product. It has been designed and manufactured to provide many years of trouble free service. IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS ! Please read this manual before installing your Enterprise 1U Rackmount Se- ries UPS, models E700RM1U, E1000RM1U, E1500RM1U, as it provides im- portant information that should be followed during installation and maintenance of the UPS and batteries allowing you to correctly set up your sy
Resumen del contenido incluido en la página 4
This symbol indicates "Direct Current Supply" This symbol indicates "Equipment Grounding Conductor" CAUTION! Connect the UPS to a two pole, three wire grounding AC wall outlet. The receptacle must be connected to the appropriate branch protection (circuit breaker or fuse). Connection to any other type of receptacle may result in a shock hazard and violate local electrical codes. Do not use extension cords, adapter plugs, or surge strips. CAUTION! To reduce the risk of electrical shock with
Resumen del contenido incluido en la página 5
English NOTICE: This equipment has been tested and found to comply with the limits for a Class A computing device in accordance with the speci- fications in Subpart J of Part 15 of FCC Rules and the Class A limits for radio noise emissions from digital apparatus set out in the Radio Interference of the Canadian Department of Communications. These limits are designed to provide reasonable protection against such interference in a residential installa- tion. This equipment generates and uses r
Resumen del contenido incluido en la página 6
Para Systems Life Support Policy As a general policy, Para Systems Inc. (Para Systems) does not recommend the use of any of its products in life support applications where failure or mal- function of the Para Systems product can be reasonably expected to cause failure of the life support device or to significantly affect its safety or effective- ness. Para Systems does not recommend the use of any of its products in direct patient care. Para Systems will not knowingly sell its products for use
Resumen del contenido incluido en la página 7
English CONTROL PANEL The AC normal (green) LED illuminates in a steady state when the UPS is on and operating in the AC normal mode. The AC normal LED will extinguish when operating in the Battery mode. The On-Battery (green) LED illuminates in a steady state when the UPS is operating in the Battery mode. The On-Battery LED will extinguish when operating in the AC normal, Boost and Buck modes. The Boost (yellow) LED illuminates in a blinking state when the UPS is operating in the Boost mode.
Resumen del contenido incluido en la página 8
The Load Level Bar Graph operates as follows: LED #10: >10% load (green/red/yellow) LED will be green and illu- minated when there is at least 10% of the rated capacity. LED #30: >30% load (green/yellow) LED will be green and illumi- nated when there is at least 30% of the rated capacity. LED #50: >50% load (green/yellow) LED will be green and illumi- nated when there is at least 50% of the rated capacity. LED #70: >70% load (green/yellow) LED will be green and illumi- nated when there is at lea
Resumen del contenido incluido en la página 9
English REAR PANEL 1. The input power cord has a NEMA 5-15P Plug. 2. The input circuit breaker will trip in the event the load exceeds the UPS’s power rating. 3. The Battery Backup output power receptacles are NEMA 5-15R type. The output receptacles are electrically wired into two segments to support the "Load Shedding Function". The three receptacles on the left are Segment 1 and the three receptacles on the right are Segment 2. 4. The RS232 Communications Interface Port is fo
Resumen del contenido incluido en la página 10
INSTALLATION Be sure to read the installation placement and all the cautions before installing the UPS. Place the UPS in the final desired location and complete the rest of the installation procedure. These UPSs are shipped with the internal batteries disconnected. The batteries must be connected before putting these UPSs into service. Follow the procedure below to connect the batteries and install the UPS into the rack. USE CAUTION: The UPS is heavy. Use the appropri- ate number of perso
Resumen del contenido incluido en la página 11
English Installing the UPS in a 4-post rack USE CAUTION: The UPS is heavy. Use the appropriate number of personnel when installing the UPS. 1. Install the rails in the 4-post rack. (FIG. 1) 2. Install the rack ears on the UPS. (FIG. 2) 3. Align the cleats with the rails and slide the UPS into the rails. (FIG. 3) NOTE: The cleats are pre-mounted on the UPS. 4. Secure the UPS to the rack with the retaining screws (not provided). The UPS is ready for normal operation, see connecting your e
Resumen del contenido incluido en la página 12
CONNECTING YOUR EQUIPMENT Plug the equipment into the output receptacles on the rear panel of the UPS. Do not use extension cords, adapter plugs or surge strips on the output of the UPS. Ensure that you do not exceed the maximum output rating of the UPS (refer to the information label on the UPS or the Electrical Specifications in this manual). DO NOT connect a laser printer to the output receptacles on the CAUTION! UPS, unless the UPS is rated 2000VA or greater. A laser printer draws signific
Resumen del contenido incluido en la página 13
English SYSTEM OVERVIEW This Line-Interactive 1U Rackmount model UPS protects internetworking and telecommunications equipment from blackouts, brownouts, overvoltages, and surges. The AVR function continuously corrects the voltages, in-between the brownout and overvoltage transfer points (85 - 150VAC), to a safe usable level. When the UPS is operating in the AVR mode the audible alarm will remain silent and the Boost or the Buck indicator will blink. During normal AC opera- tion, the MINUTEMAN
Resumen del contenido incluido en la página 14
SELF TEST The self test feature is useful to verify the correct operation of the UPS and the condition of the batteries. With the UPS in the AC normal mode, press and hold the On/Off/Test Button for four beeps, then release the button. The UPS will perform a ten-second self test. During the self test, the UPS will switch to battery power and the On-Battery LED will illuminate and the audible alarm will sound. The length of the test that is automatically performed every two weeks is longer th
Resumen del contenido incluido en la página 15
English OVERLOAD When the amount of load attached to the UPS exceeds its power rating, the Overload LED will illuminate and the UPS will sound a constant alarm. This alarm will remain on until the excess load is removed or the UPS’s self protec- tion circuit shuts the UPS down. WEAK/BAD BATTERY The UPS automatically tests the battery’s condition and will illuminate the Weak/ Bad Battery LED and sound the alarm. This alarm will be repeated until the batteries pass a self test. If the battery is
Resumen del contenido incluido en la página 16
What To Do Symptom Possible Cause UPS will not turn on On/Off/Test button not Press and release the On/Off/ pushed Test button to start UPS UPS operates in Input AC circuit breaker is Reset circuit breaker by battery mode only, tripped pressing the plunger back in. even though there is If the AC circuit breaker trips normal AC present after UPS starts up, reduce the load on the UPS Fault LED is UPS has detected an Call for service illuminated internal fault Have a Qualified Electrician Incorrec
Resumen del contenido incluido en la página 17
English REPLACING THE BATTERY (QUALIFIED SERVICE PERSONNEL ONLY) The Enterprise 1U Rackmount Series UPS has an easy to replace hot-swappable batteries. Please read all of the WARNINGS and CAUTIONS before attempt- ing to service the batteries. NOTE: If there is a power interruption while replacing the hot-swappable batteries, with the UPS on, the load will not be backed up. This Uninterruptible Power Supply contains potentially hazardous WARNING! voltages. Do not attempt to disassemble the UPS b
Resumen del contenido incluido en la página 18
CAUTION: Replace batteries with the same number and type as originally installed in the UPS. These batteries have pressure operated vents. These UPSs contain sealed non-spillable lead acid batteries. E700RM1U E1500RM1U Model # E1000RM1U Battery 4-6V9Ah 4-6V9Ah 4-6V9Ah Qty/Rating EPOWER HR9-6 HR9-6 HR9-6 Part # Panasonic UP-RW0645Ch1 UP-RW0645Ch1 UP-RW0645Ch1 Part # CSB HRL634WF2FR HRL634WF2FR HRL634WF2FR Part # Yuasa VALA NPW 45-6 VALA NPW 45-6 VALA NPW 45-6 Part # BATTERY REPLACEMENT PROCEDUR
Resumen del contenido incluido en la página 19
English 8. Remove the four retaining screws for the battery retaining bracket. (FIG. 3) 9. Remove the battery retaining bracket. (FIG. 3) 10. Grasp the battery tray and gently pull the battery tray out far enough to get to the battery connectors (red and black). (FIG. 4) 11. Disconnect the battery connectors (red and black). (FIG. 5) 12. Gently remove the battery tray from the UPS and set on the floor. NOTE: Use Caution, the battery tray is heavy. 13. Remove the battery jumper wires. 14.
Resumen del contenido incluido en la página 20
IF THE UPS REQUIRES SERVICE 1.Use the TROUBLESHOOTING section to eliminate obvious causes. 2.Verify there are no circuit breakers tripped. A tripped circuit breaker is the most common problem. 3.Call your dealer for assistance. If you cannot reach your dealer, or if they cannot resolve the problem call or fax MINUTEMAN Technical Support at the following numbers; Voice phone (972) 446-7363, FAX line (972) 446-9011 or visit our Web site at www.minutemanups.com the "Discussion Board". Please