Resumen del contenido incluido en la página 1
1500 Watt DC to AC Power Inverter
C o n v e r t s 1 2 V D C B a t t e r y P o w e r
t o 1 1 0 V A C H o m e P o w e r
O W N E R ' S M A N U A L
– SAVE THESE INSTRUCTIONS –
The recommended source of power is a 12-volt deep-cycle battery
due to their high reserve power capacity. Automotive batteries
are recommended for only a short period of time of an hour or less.
Model PI-1500 00-99-000628/0206
Resumen del contenido incluido en la página 2
The advanced surge capacity of the PI-1500 power inverter gives it the means to start most electrical devices including: color televisions, TV/VCR/d Vd combinations, small microwaves, refrigeration electric coolers, small air conditioners. Warning: Handling the cord on this product or cords associated with accessories sold with this product, may expose you to lead, a chemical known to the State of California to cause cancer and birth defects or other reproductive harm. Wash hands after h
Resumen del contenido incluido en la página 3
• d o not place the inverter in direct sunlight. The ideal air temperature for operation is between 30º and 105ºF. • Keep the inverter well ventilated in order to properly dis- perse heat generated while it is in use. • While in use, make sure there are several inches of clear- ance around the top and sides of the inverter. • Do not use the inverter near flammable materials. • d o not place or install the inverter in areas such as bat- tery or engine compartments where fumes or gases may accu
Resumen del contenido incluido en la página 4
• If you are powering the inverter with an automobile or ma- rine battery, start the engine every 30 to 45 minutes and let it run for about 10 minutes to recharge the battery. • If you hear a continuous alarm or automatic shut down, turn the inverter o FF immediately. d o not restart the inverter until the source of the problem has been identified and corrected. • d isconnect the inverter when not in use in order to avoid battery drain. Before Using PI-1500 It is important to know the conti
Resumen del contenido incluido en la página 5
In the event of a power overload, the inverter is designed to automatically shut down. This safety feature prevents damaging the inverter while testing devices and equip- ment within the 1500-watt range. If a device will not operate properly when first connected to the inverter, turn the inverter rocker switch o N (I), o FF (o ), and o N (I) again in quick succession. If this proce- dure is not successful, it is likely that the PI-1500 inverter does not have the required capacity to operate
Resumen del contenido incluido en la página 6
2. Place the back of the PI-1500 with the mounting bracket against a secure and flat surface. 3. Attach the inverter to the flat surface using corrosion resistant screws. Inverter Features: A. o N/o FF Rocker Switch – Turns inverter on and off. B. led Indicator l ight – (Green = power o N, Red = o verload, interruption in power). C. Two, 110V GFCI AC o utlets d . o ne Pair, 12-Volt Power Cords e. Two, High Speed Cooling Fans – keeps inverter cool. The speed of the fan is faster as the load i
Resumen del contenido incluido en la página 7
Grounding the PI-1500 To avoid electrical shock, it is necessary to ground the PI-1500 Inverter as well as the device powering it. The inverter should be grounded using #8 AWG copper wire (not included). Note: d o not turn on the inverter or the power source until the inverter and the power source are grounded. 1. Turn off the PI-1500. 2. l ocate the chassis ground screw underneath the negative terminal on the left side of the inverter. Unscrew the two hex nuts and one washer. 3. Strip the
Resumen del contenido incluido en la página 8
Connecting Inverter Cables The inverter and the power source must be in the o FF mode. Inverter Connection: 1. l ocate the positive and negative plastic terminals located on the left side of the inverter. Using a flathead or standard screwdriver, unscrew the positive (red) and negative (black) terminal screws just enough to be able to insert the bare end of the connector cables. 2. Insert the bare end of the positive (red) cable into the positive terminal and bare end of the negative (bla
Resumen del contenido incluido en la página 9
Connecting Your PI-1500 t o t urn o N: 1. Push the rocker switch, located on the right side, to the “o N” (I) position. The led indicator light should glow GRee N verifying the inverter is receiving power and can deliver power to your device. (A brief audio alarm may sound or red LED may flash. This is normal.) 2. Turn on the power source or device to be powered. Note: If more than two devices are to be powered, start one device at a time to avoid a power surge and overload- ing the inver
Resumen del contenido incluido en la página 10
Using GFCI o utlet The GFCI (Ground Fault Interrupter) must be tested before each use. To test: 1. Turn the inverter o N. 2. Push the "ReSeT" button located on the GFCI receptacle, first to assure normal GFCI operation. 3. Plug a nightlight (with an "o N/o FF" switch) or other product (such as a lamp) into the GFCI receptacle and turn the product "o N." 4. Push the "TeST" button located on the GFCI receptacle. The nightlight or other product should go "o FF." 5. Push the "ReSeT" button,
Resumen del contenido incluido en la página 11
inverter to reset. To reset: press the “TeST” button (stops flow of electricity to outlet) on the outlet face. Next, press the “RESET” button (restores flow of electricity to outlet) on the outlet face. LeDs and Audio Alarms Green – Power o n Red l ight and/or Audio Alarm Current o verload – Red led glows for a short time and inverter shuts down. Current load too high for inverter. Reduce current demand. Voltage o verload – Red led glows and inverter shuts down. Voltage range of 15.5V ± 0.
Resumen del contenido incluido en la página 12
power consumption. When the inverter is o FF, no lights appear. Using the Inverter to o perate a t V or Audio Device The inverter is shielded and filtered to minimize signal interference. d espite this, some interference may occur with your television picture, especially with weak signals. Below are some suggestions to try and improve reception. Make sure the television antenna produces a clear signal under normal operating conditions (i.e., at home plugged into a standard 115V AC wall out
Resumen del contenido incluido en la página 13
Blown Fuse A blown fuse is usually caused by reverse polarity or a short circuit within the device or equipment being operated. If the fuse blows, take the inverter to a qualified techni- cian for repair. Power Source Your average automobile or marine battery will provide an ample power supply to the inverter for 30 to 45 minutes even when the engine is off. The actual length of time the inverter will function depends on: 1. Age and condition of the battery. 2. Power demand being placed b
Resumen del contenido incluido en la página 14
Safety Features The led Indicator light will turn from GR eeN to R ed and the inverter will automatically turn itself off when: 1. The power input from the battery drops to approximately 10 volts. (When the power input drops to approximately 10.5 volts, an alarm will sound for an extended period). 2. The power input from the battery exceeds 15.5 volts. 3. The continuous load demand from the equipment or device being operated exceeds 1500 watts. 4. The case temperature exceeds 140 ºF. Atten
Resumen del contenido incluido en la página 15
St AGe 2: The inverter then converts the 145-volts d C into 110-volts AC (household voltage) using advanced MOSFET transistors in a full bridge configuration. A "modi- fied sine wave" waveform is generated by this conversion. t roubleshooting PRo BLeM: Low or No o utput Voltage Reason/Solution 1. Poor contact at terminals. Unhook and rehook the 12-volt connections. 2. Using incorrect type of voltmeter to test output voltage. Use a true RMS reading meter. PRo BLeM: Red LeD o n Reason/So
Resumen del contenido incluido en la página 16
PRo BLeM: Audible Alarm o n All t he t ime Reason/Solution 1. Input voltage below 11 volts. Recharge or replace battery to maintain adequate power input. 2. Poor or weak battery condition. Recharge or replace battery. PRo BLeM: Device Does Not Work Reason/Solution 1. Device does not turn on. Try turning the inverter o N, then o FF, then o N again. Contact the device manufacture for start up surge and/or if the device is compatible with a modified sine wave. An inverter producing a la
Resumen del contenido incluido en la página 17
SPeCIFICAt Io NS: Maximum Continuous Power ............................ 1500 watts Surge Capability (Peak Power) ........................ 3000 Watts No l oad Current d raw ............................................. < 0.6A Wave form ...........................................Modified Sine Wave Input Voltage Range ....................................10.5V–15V d C AC outlets ..................................................Two, 110V GFCI LIMIte D WARRANt Y Schumacher electric Corporation warr
Resumen del contenido incluido en la página 18
Schumacher electric Corporation, Warranty Service d epartment 1025 Thompson, Hoopeston, Il 60942 Phone: 800-621-5485 (Hours: a.m. - 4:30 p.m. CST) You will be responsible for all insurance and freight or other transportation charges to the factory or point of repair. We will return your inverter freight prepaid if repair is covered under warranty. Your inverter should be prop- erly packed to avoid damage in transit since we will not be responsible for any such damage. In no event shall