Resumen del contenido incluido en la página 1
You can rely on
User Guide and Gold System
Important Warranty Information HE A
Range
Condensing
System Boiler
Please keep these instructions in a safe place.
If you move house, please hand them over to
the next occupier.
© Baxi Heating UK Ltd 2010
Resumen del contenido incluido en la página 2
Contents Section Page Natural Gas 1.0 Quick Reference Guide 3 Potterton Gold System 18 HE A o G.C.N 41 592 15 2.0 Troubleshooting 4 Potterton Gold System 24 HE A o G.C.N 41 592 16 3.0 Repressurising System 6 Potterton Gold System 28 HE A o G.C.N 41 592 17 4.0 Clearances 7 5.0 Care of the Boiler 8 6.0 Legislation 9 7.0 Notes 10 8.0 Emergency 11 9.0 Warranty & Service 12 The Benchmark Scheme Baxi Heating UK Ltd is a licensed member of the Benchmark Scheme which aims to improve the standards of
Resumen del contenido incluido en la página 3
1.0 Quick Reference Guide 2 Reset 1 3 0 4 bar ON/OFF/Reset Display Central Heating Calibration Control System Pressure Gauge Selector Switch Temperature Control Reset Reset Reset OFF Position Central Heating & Hot Water Reset The boiler will not operate. Both Heating & Hot Water will operate. Hold for approx 5 seconds and release. Central Heating Indicator - The indicator will illuminate when the boiler is in the central heating mode. Burner On Indicator - The indicator will illuminate when the
Resumen del contenido incluido en la página 4
Boiler not working 2.0 Troubleshooting START Make sure the gas supply is Is the ( ) light on and the YES YES NO Is the ON/OFF/Reset turned ON and check if other ( ) on ? Select Switch in the gas appliances are operating ( ) position and (e.g. fire, cooker). Central Heating the display lit ? Indicator NO If no gas, consult your supplier. Reset Burner On Indicator YES Display NO Boiler operating satisfactorily. Check electricity to the boiler is switched on. Is the Central He
Resumen del contenido incluido en la página 5
5 4 3 2 25 25 1 20 20 2.0 Troubleshooting Is the Timer ON and calling for Is the Room Thermostat (if YES YES heat ? fitted) set high enough ? 12 15 Typical examples of external timer CH OFF CH ON NO Turn Room Thermostat to maximum setting (typical example shown). NO Ensure timer is set for Central 15 Heating ON (see any instructions supplied with timer). CONTACT YOUR INSTALLER OR SERVICE ENGINEER. If you don’t know what you need to do to get the boiler to light, or need help with the system and
Resumen del contenido incluido en la página 6
3.0 Repressurising System 2 3.1 Central Heating System Pressure 1 3 1. The normal operating water pressure is between 1 and 2.5 bar (Fig. 1). If the pressure exceeds 3 bar the 0 4 safety pressure valve will operate and a fault is indicated. bar Contact your installer. Fig. 1 Normal Pressure 2. It may be necessary to repressurise the system occasionally (Fig. 2). A filling device (the filling loop) will be fitted on the system. 2 1 3 3. If you are unsure of its position, or cannot identify it, co
Resumen del contenido incluido en la página 7
4.0 Clearances 4.1 For your Safety 5mm Min 450mm 5mm Min 1. This appliance must have been installed in accordance with the manufacturer’s instructions and the regulations in force. 200mm Min (300mm Min if 2. Any modification that may interfere with the normal using 80/125mm operation of the appliance without express written flueing system permission from the manufacturer or his agent could invalidate the appliance warranty. In GB this could also infringe the Gas Safety (Installation and Use) Reg
Resumen del contenido incluido en la página 8
5.0 Care of the Boiler 5.1 Cleaning the Outer case The painted panels should be wiped with a damp cloth and then dried completely. DO NOT USE ABRASIVE CLEANING AGENTS. 5.2 Protection & Precaution 1. The boiler incorporates an integral frost protection feature that will operate when the selector switch is in the ( ) position. If the boiler temperature falls below 5° C, then the boiler will operate until the water temperature has been raised. 2. If a system frost thermostat has been fit
Resumen del contenido incluido en la página 9
6.0 Legislation 6.1 Installation, Commissioning, Service & Repair 1. This appliance must be install in accordance with the manufacturer’s instructions and the regulations in force. Read the instructions fully before installing or using the appliance. 2. In GB, this must be carried out by a competent person as stated in the Gas Safety (Installation & Use) Regulations. 3. Definition of competence: A person who works for a Gas Safe registered company and holding current certificates in the relevant
Resumen del contenido incluido en la página 10
7.0 Notes 10 © Baxi Heating UK Ltd 2010
Resumen del contenido incluido en la página 11
8.0 Emergency Warning ! If you smell gas Do not operate light switches Do not operate any electrical equipment Do not use a telephone in the hazardous area Extinguish any naked flame and do not smoke Open windows and doors in the hazardous area Turn off the gas supply at the meter Warn any other occupants and vacate the premises Telephone the National Gas Emergency Service on:- 0800 111 999 Faulty boiler If it is known or suspected that a fault exists on the boiler, it must not be used until th
Resumen del contenido incluido en la página 12
Please complete the boxes below 9.0 Warranty & Service Serial Number Standard Warranty Terms & Conditions To activate your second year free warranty you must register your boiler with heateam the service division of Baxi Heating UK Ltd either by completing and returning the registration card or calling our telephone registration line on 0800 731 1644. It is also a requirement of the warranty that the boiler has an annual service (every 12 months) in accordance with the installation and servicing