Resumen del contenido incluido en la página 1
Technical Data Sheet
™
VNA Master
Handheld Vector Network Analyzer + Spectrum Analyzer
MS2026C MS2036C MS2028C MS2038C
5 kHz to 6 GHz 5 kHz to 6 GHz 5 kHz to 20 GHz 5 kHz to 20 GHz Vector Network Analyzer
9 kHz to 9 GHz 9 kHz to 20 GHz + Spectrum Analyzer
The Ultimate Handheld Vector Network + Spectrum Analyzer
for Cable, Antenna and Signal Analysis Anytime, Anywhere
Introduction
High Performance Handheld S-Parameters
Anritsu introduces the MS202x/3xC VNA Master + Spectrum Analyzer, the indu
Resumen del contenido incluido en la página 2
Performance and Functional Highlights VNA Master • Broadband coverage of 5 kHz to 6/20 GHz • Full Speed USB Memory support • True 2-port Vector Network Analyzer (VNA) • High resolution daylight viewable TFT color display • Ultimate accuracy with 12-term error correction • Time Domain option for Distance-to-Fault diagnostics • User-defined quad display for viewing all 4 S-Parameters • Internal Bias Tee option • Arbitrary data points up to 4001 • Vector Voltmeter option • IF Bandwi
Resumen del contenido incluido en la página 3
VNA Master Functional Specifications Definitions • All specifications and characteristics apply under the following conditions, unless otherwise stated: • After 30 minutes of warm-up time, where the instrument is in VNA Mode and left in the ON state. • Temperature range is 23 ºC ± 5 ºC. • All specifications apply when using internal reference. • All specifications subject to change without notice. Please visit www.us.anritsu.com for most current data sheet. • Typical performance is t
Resumen del contenido incluido en la página 4
Uncertainty Curves for Round-Trip Cable Loss Measurements (1-Port) Round-trip cable loss measurements are convenient for field personnel testing installed cable or waveguide runs. This one-port technique provides one-way data after twice traversing the cable. The following two sets of uncertainty curves, less than 6 GHz on the left and greater than 6 GHz on the right, present worst-case uncertainty by DUT Match (i.e., Log Mag) when using VNA Master for one-port cable loss measurements. As a
Resumen del contenido incluido en la página 5
High Port Power OSLxx50 Calibration Components (N-Connectors) Corrected System Performance and Uncertainties: MS202x/3xC Model with 12-term SOLT calibration including isolation using either OSLN50 & OSLNF50 or OSLK50 & OSLKF50 Calibration Kits Precision calibration standards come in a convenient configuration for field work. Frequency Range (GHz) Directivity (dB) Frequency Range (GHz) Typical High Port Power (dBm) ≤ 5 > 2 ≤ 3 +3 ≤ 15 > 36 ≤ 6 –3 ≤ 20* > 32 ≤ 20 –3 * N Connector guarantee
Resumen del contenido incluido en la página 6
Low Port Power OSLxx50 Calibration Components Corrected System Performance and Uncertainties: MS202x/3xC Model with 12-term SOLT calibration including isolation using either OSLN50 & OSLNF50 or OSLK50 & OSLKF50 Calibration Kits Frequency Range (GHz) Directivity (dB) Frequency Range (GHz) Typical High Port Power (dBm) ≤ 5 > 42 ≤ 3 –25 ≤ 15 > 36 ≤ 6 –25 ≤ 20* > 32 ≤ 20 –15 * N Connector guaranteed to 18 GHz, typical > 18 GHz Measurement Uncertainties The following graphs provide measurement u
Resumen del contenido incluido en la página 7
High Port Power 3652A Calibration Kit (K-Connector) Corrected System Performance and Uncertainties: MS202x/3xC Model with 12-term SOLT calibration including isolation using 3652A Calibration Kit Frequency Range (GHz) Directivity (dB) Frequency Range (GHz) Typical High Port Power (dBm) ≤ 5 > 2 ≤ 3 +3 ≤ 15 > 36 ≤ 6 –3 ≤ 20* > 32 ≤ 20 –3 * N Connector guaranteed to 18 GHz, typical > 18 GHz Measurement Uncertainties The following graphs provide measurement uncertainty at 23 ºC ± 5 ºC for the abo
Resumen del contenido incluido en la página 8
Low Port Power 3652A Calibration Kit (K-Connector) Corrected System Performance and Uncertainties: MS202x/3xC Model with 12-term SOLT calibration including isolation using 3652A Calibration Kit Frequency Range (GHz) Directivity (dB) Frequency Range (GHz) Typical Low Port Power (dBm) ≤ 5 > 2 ≤ 3 –25 ≤ 15 > 36 ≤ 6 –25 ≤ 20* > 32 ≤ 20 –25 * N Connector guaranteed to 18 GHz, typical > 18 GHz Measurement Uncertainties The following graphs provide measurement uncertainty at 23 ºC ± 5 ºC for the ab
Resumen del contenido incluido en la página 9
+ Spectrum Analyzer Functional Specifications (Models MS2036/38C only) Frequency Frequency Range 9 kHz to 20 GHz (usable to 0 Hz), Preamp 100 kHz to 20 GHz Tuning Resolution 1 Hz Aging: ± 1.0 ppm/10 years Frequency Reference Accuracy: ± 0.3 ppm (25 °C ± 25 °C) + aging External Reference Frequencies 1, 1.2288, 1.544, 2.048, 2.4576, 4.8, 4.9152, 5, 9.8304, 10, 13, 19.6608 MHz Frequency Span 10 Hz to 20 GHz including zero span Sweep Time 10 μs to 600 seconds in zero span Sweep Time Accuracy ± 2% in
Resumen del contenido incluido en la página 10
+ Spectrum Analyzer Functional Specifications (Models MS2036/38C only) (continued) Spurs Preamp Off (RF input terminated, 0 dB input attenuation) –90 dBm 9 kHz to 13 GHz –85 dBm 13 GHz to 20 GHz Residual Spurious Preamp On (RF input terminated, 0 dB input attenuation) –100 dBm 1 MHz to 20 GHz (0 dB attenuation, –30 dBm input, span < 1.7 GHz) Input-Related Spurious –60 dBc, –70 dBc typical Third-Order Intercept (TOI) (–20 dBm tones 100 kHz apart, –20 dBm Ref level, 0 dB input attenuation, preamp
Resumen del contenido incluido en la página 11
VNA Performance Capabilities (MS202x/3xC) Measurement Parameters S , S , S , S , S , S , S , S 11 21 22 12 d1d1 c1c1 d1c1 c1d1 Four: TR1, TR2, TR3, TR4 Number of Traces Trace Format Single, Dual, Tri, Quad. When used with Number of Traces, overlays are possible including a Single Format with Four trace overlays. Log Magnitude SWR Phase Real Imaginary Group Delay Graph Types Smith Chart Log Mag / 2 (1-Port Cable Loss) Linear Polar Log Polar Real Impedance Imaginary Impedance Frequency Domain,
Resumen del contenido incluido en la página 12
+ Spectrum Analyzer Performance Capabilities Measurements Field Strength (uses antenna calibration tables to measure dBm/m2 or dBmV/m) Occupied Bandwidth (measures 99% to 1% power channel of a signal) Channel Power (measures the total power in a specified bandwidth) Smart Measurements ACPR (adjacent channel power ratio) C/I (carrier-to-interference ratio) Emission Mask (recall limit lines as emission mask) Setup Parameters Frequency Center/Start/Stop, Span, Frequency Step, Signal Standard, Chann
Resumen del contenido incluido en la página 13
Measurement Options Specifications Time Domain (Option 0002) (includes Distance Domain Option 0501) The VNA Master can also display the S-parameter measurements in the time or distance domain using lowpass or bandpass processing analysis modes. The broadband frequency coverage coupled with 4001 data points means you can measure discontinuities both near and far with unprecedented clarity for a handheld tool. With this option, you can simultaneously view S-parameters in frequency, time, and di
Resumen del contenido incluido en la página 14
Bias Tee (Option 0010) Vector Voltmeter (Option 0015) For tower mounted amplifier tests, the MS20x/3xC series A phased array system relies on phase matched cables for with optional internal bias tees can supply both DC and RF nominal performance. For this class of application, the VNA signals on the center conductor of the cable during Master offers this special software mode to simplify phase measurements. For frequency sweeps in excess of 2 MHz, matching cables at a single frequency. The si
Resumen del contenido incluido en la página 15
High Accuracy Power Meter (Option 0019) Requires external USB power sensor. Conduct precise measurements of CW and digitally modulated transmitters in the field using this VNA Master software mode with a separately purchased Anritsu USB power sensor. After specifying the center frequency and zeroing the sensor to ensure accuracy at low power levels, the software offers intuitive operation for absolute and relative readouts in dBm or Watts. Option 0019 supports the USB Power Sensors in the fo
Resumen del contenido incluido en la página 16
GPS (Option 0031), (Models MS2036/38C only) Requires external GPS antenna Built-in GPS provides location information (latitude, longitude, altitude) and Universal Time (UT) information for storage along with trace data so you can later verify that measurements were taken at the right location. The GPS option requires a separately ordered magnet mount GPS antenna (2000-1528-R), which is configured with a 15 foot (~5 m) cable to mount outside on a metallic surface. Frequency accuracy is enhance
Resumen del contenido incluido en la página 17
VNA Master General Specifications (MS202x/3xC) Setup Parameters Size and Weight Status (Temperature, Battery Info, S/N, Firmware Ver, IP Height 211 mm (8.3 in) Address, Options Installed) System Width 315 mm (12.4 in) Self Test, Application Self Test Dimensions GPS (see Option 0031) 78 mm (3.1 in) (MS202xC) Depth 97 mm (3.8 in) (MS203xC) Name, Date and Time, Ethernet Configuration, Brightness, Volume Language (English, French, German, Spanish, Chinese, 4.5 kg (9.9 lbs) (MS202xC) System Options
Resumen del contenido incluido en la página 18
Ancillary Module extends Optical Fiber Testing to Distance-to-Fault The ODTF-1 module is primarily intended for field use by technicians and engineers responsible for the deployment and maintenance of remote radio heads (RRH), and nicely complements the field diagnostic power of the VNA Master. The ODTF-1 module is fully compatible with the MS202x/3xC VNA Masters which are equipped with the Time Domain Option 0002 or Distance Domain Option 0501. Field operation of the ODTF-1 module with the V
Resumen del contenido incluido en la página 19
Master Software Tools and Remote Programming ® Each VNA Master ships with a versatile test assistant: a copy of Anritsu’s Master Software Tools for Windows 2000/XP/Vista/7. This allows an operator to add the processing capabilities of a PC and this software utility to the VNA Master to form a powerful and flexible measurement solution for network analysis. For automation, the VNA Master also supports remote programming via the Ethernet or USB interface. Connect VNA Master to a PC for archivin
Resumen del contenido incluido en la página 20
Ordering Information 1 1 1 1 MS2026C MS2028C MS2036C MS2038C VNA Master, VNA Master, VNA Master VNA Master 2-port, VNA 2-port, VNA + Spectrum Analyzer, S/A + Spectrum Analyzer, S/A 5 kHz to 6 GHz 5 kHz to 20 GHz 9 kHz to 9 GHz 9 kHz to 20 GHz Options Description MS2026C-0002 MS2028C-0002 MS2036C-0002 MS2038C-0002 Time Domain (includes DTF capability) MS2026C-0005 MS2028C-0005 – – Power Monitor (requires external detector) MS2026C-0007 MS2028C-0007 MS2036C-0007 MS2038C-0007 Secure Data O