Resumen del contenido incluido en la página 1
®
MegaRAID Express 500
Hardware Guide
MAN-475
6/13/2001
Resumen del contenido incluido en la página 2
© Copyright 2001 LSI Logic Corporation All rights reserved. LSI Logic Corporation 6145-D Northbelt Parkway Norcross, GA 30071 This publication contains proprietary information which is protected by copyright. No part of this publication can be reproduced, transcribed, stored in a retrieval system, translated into any language or computer language, or transmitted in any form whatsoever without the prior written consent of the publisher, LSI Logic Corporation. LSI Logic Corporation acknowledges th
Resumen del contenido incluido en la página 3
Table of Contents 1 Overview .................................................. 1 Single Ended and Differential SCSI Buses.......................2 Maximum Cable Length for SCSI Standards....................2 Documentation..................................................................3 MegaRAID Express 500 Block Diagram..........................4 2 Introduction to RAID................................ 5 RAID Benefits ..................................................................5 In This Ch
Resumen del contenido incluido en la página 4
Table of Contents, Continued 4 Features ................................................. 27 Hardware Requirements .................................................28 Configuration Features ...................................................28 Hardware Architecture Features .....................................29 Array Performance Features ...........................................29 RAID Management Features ..........................................30 Fault Tolerance Features..................
Resumen del contenido incluido en la página 5
Table of Contents, Continued 6 Hardware Installation............................ 49 Checklist .........................................................................49 Installation Steps.............................................................50 Step 1 Unpack.................................................................51 Step 2 Power Down ........................................................51 Step 3 Configure Motherboard .......................................51 Step 4 Install Cach
Resumen del contenido incluido en la página 6
Table of Contents, Continued 8 Troubleshooting .................................... 99 BIOS Boot Error Messages ..........................................101 Other BIOS Error Messages .........................................103 DOS ASPI Driver Error Messages ...............................104 Other Potential Problems..............................................105 A SCSI Cables and Connectors............. 107 SCSI Connectors...........................................................107 68-Pin
Resumen del contenido incluido en la página 7
Preface The MegaRAID Express 500 PCI RAID Controller supports all single ended and low-voltage differential (LVD) SCSI devices on a 160M Ultra and Wide SCSI channel with data transfer rates up to 160 MB/s (Megabytes per second). This manual describes MegaRAID Express 500. Limited Warranty The buyer agrees if this product proves to be defective, that LSI Logic is obligated only to repair or replace this product at LSI Logic’s discretion according to the terms and conditions of the warranty regist
Resumen del contenido incluido en la página 8
Preface, Continued Package Contents You should have received: • a MegaRAID Express 500 PCI RAID Controller • a CD with drivers, utilities, and documentation • a MegaRAID Express 500 Hardware Guide (on CD) • a MegaRAID Configuration Software Guide (on CD) • a MegaRAID Operating System Drivers Guide (on CD) • software license agreement (on CD) • a warranty registration card (on CD) Technical Support If you need help installing, configuring, or running the MegaRAID Express 500 PCI RAID Controller
Resumen del contenido incluido en la página 9
MegaRAID Problem Report Form Customer Information MegaRAID Information Name Today’s Date Company Date of Purchase Address Invoice Number City/State Serial Number Country email address Cache Memory Phone Firmware Version Fax BIOS Version System Information Motherboard: BIOS manufacturer: Operating System: BIOS Date: Op. Sys. Ver.: Video Adapter: MegaRAID CPU Type/Speed: Driver Ver.: Network Card: System Memory: Other disk controllers Other adapter cards installed: installed: Description of proble
Resumen del contenido incluido en la página 10
Logical Drive # of Physical Logical RAID Stripe Cache Read Write Size Drives Drive Level Size Policy Policy Policy LD20 LD21 LD22 LD23 LD24 LD25 LD26 LD27 LD28 LD29 LD30 LD31 LD32 LD33 LD34 LD35 LD36 LD37 LD38 LD39 x MegaRAID Express500 Hardware Guide
Resumen del contenido incluido en la página 11
Physical Device Layout Channel 1 Target ID Device Type Logical Drive Number/ Drive Number Manufacturer/Model Number Firmware level Target ID Device Type Logical Drive Number/ Drive Number Manufacturer/Model Number Firmware level Target ID Device Type Logical Drive Number/ Drive Number Manufacturer/Model Number Firmware level Target ID Device Type Logical Drive Number/ Drive Number Manufacturer/Model Number Firmware level Target ID Device Type Logical Drive Number/ Drive Number Manufacturer/Model
Resumen del contenido incluido en la página 12
Channel 1 Logical Drive Number/ Drive Number Manufacturer/Model Number Firmware level Target ID Device Type Logical Drive Number/ Drive Number Manufacturer/Model Number Firmware level Target ID Device Type Logical Drive Number/ Drive Number Manufacturer/Model Number Firmware level Target ID Device Type Logical Drive Number/ Drive Number Manufacturer/Model Number Firmware level Target ID Device Type Logical Drive Number/ Drive Number Manufacturer/Model Number Firmware level xii MegaRAID Express50
Resumen del contenido incluido en la página 13
Preface, Continued Disclaimer This manual describes the operation of the LSI Logic MegaRAID Express 500 Disk Array Controller. Although efforts have been made to assure the accuracy of the information contained here, LSI Logic expressly disclaims liability for any error in this information, and for damages, whether direct, indirect, special, exemplary, consequential or otherwise, that may result from such error, including but not limited to the loss of profits resulting from the use or misuse of
Resumen del contenido incluido en la página 14
FCC Regulatory Statement This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Warning: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Note: This equipment has been
Resumen del contenido incluido en la página 15
1Overview The MegaRAID® Express 500 PCI RAID controller is a high performance intelligent PCI-to-SCSI host adapter with RAID control capabilities. The MegaRAID Express 500 provides reliability, high performance, and fault-tolerant disk subsystem management. The MegaRAID Express 500 is part of the LSI Logic Intel i960RM/RS-based MegaRAID controller family. The MegaRAID Express 500 is an entry level-to mid-range RAID controller solution. MegaRAID Express 500 offers a cost-effective way to implemen
Resumen del contenido incluido en la página 16
Single Ended and Differential SCSI Buses The SCSI standard defines two electrical buses: • a single ended bus • low-voltage differential bus Maximum Cable Length for SCSI Standards Standard Single ended LVD Maximum Number of Drives SCSI I 6 m 12 m 7 Fast SCSI 6 m 12 m 7 Fast Wide SCSI 6 m 12 m 15 Ultra SCSI 1.5 m 12 m 7 Ultra SCSI 3 m 12 m 3 Wide Ultra SCSI 12 m 15 Wide Ultra SCSI 1.5 m 12 m 7 Wide Ultra SCSI 3 m 12 m 3 Ultra 2 SCSI 25 m 1 Ultra 2 SCSI 12 m 7 Wide Ultra 2 SCSI 25 m 1 Wide Ultra
Resumen del contenido incluido en la página 17
Documentation The MegaRAID Express 500 technical documentation set includes: • the MegaRAID Elite 1600 Hardware Guide • the MegaRAID Configuration Software Guide • the MegaRAID Operating System Drivers Guide MegaRAID Configuration Hardware Guide This manual contains the RAID overview, RAID planning, and RAID system configuration information you will need first. Read the MegaRAID Express 500 Hardware Guide first. MegaRAID Configuration Software Guide This manual describes the software configurati
Resumen del contenido incluido en la página 18
MegaRAID Express 500 Block Diagram 4 MegaRAID Express 500 Hardware Guide
Resumen del contenido incluido en la página 19
2 Introduction to RAID RAID (Redundant Array of Independent Disks) is an array of multiple independent hard disk drives that provide high performance and fault tolerance. A RAID disk subsystem improves I/O performance over a computer using only a single drive. The RAID array appears to the host computer as a single storage unit or as multiple logical units. I/O is expedited because several disks can be accessed simultaneously. RAID systems improve data storage reliability and fault tolerance com
Resumen del contenido incluido en la página 20
In This Chapter The following topics are discussed: Major Topic Subtopic turn to Host-based RAID solution page 7 RAID overview page 8 Consistency check page 8 Fault tolerance page 8 Disk rebuild page 9 Hot spares Page 10 Hot swaps page 10 Parity page 11 Disk striping page 12 Disk mirroring page 13 Disk spanning page 14 Logical drive page 15 Logical drive states page 15 SCSI drive states page 15 Disk array types page 16 Enclosure management page 16 6 MegaRAID Express 500 Hardware Guide