T3SU 300
T3 Service Unit
USER MANUAL
1200217L1 T3SU 300
1200217L2 T3SU 300 with Internal Modem
1200218L1 HSSI DTE Interface Card
1200219L1 V.35 DTE Interface Card
61200217L1-1B
December 1998
Resumen del contenido incluido en la página 2
Trademark Information: OpenView is a trademark of Hewlett-Packard Company. Spectrum is a registered trademark of Cabletron. Netview is a registered trademark of IBM. 901 Explorer Boulevard P.O. Box 140000 Huntsville, AL 35814-4000 Phone: (256) 963-8000 © 1998 ADTRAN, Inc. All rights reserved. Printed in USA.
Resumen del contenido incluido en la página 3
ABOUT THIS MANUAL This manual is arranged so you can quickly and easily find the information you need. The following is an overview of the contents of this manual: • Chapter 1, Introduction, familiarizes you with T3 networks and T3SU 300 highlights and gives a brief explanation of options that may be purchased for use with the T3SU 300. • Chapter 2, Installation and Operation, describes the T3SU 300 connectors (pin assignments are given in Appendix A), provides installation instruc- tions,
Resumen del contenido incluido en la página 4
Notes provide additional useful information. Cautions signify information that could prevent service interrup- tion. Warnings provide information that could prevent damage to the equipment or endangerment to human life. IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS When using your telephone equipment, please follow these basic safety precautions to reduce the risk of fire, electrical shock, or personal injury: 1. Do not use this product near water, such as near a bath tub, wash bowl, k
Resumen del contenido incluido en la página 5
FCC regulations require that the following information be provided in this manual: 1. This equipment complies with Part 68 of FCC rules. On the bottom of the equip- ment housing is a label showing the FCC registration number and ringer equiva- lence number (REN) for this equipment. If requested, provide this information to the telephone company. 2. If this equipment causes harm to the telephone network, the telephone company may temporarily discontinue service. If possible, advance notificati
Resumen del contenido incluido en la página 6
YEAR 2000 COMPLIANCE All ADTRAN transmission hardware and software products have been tested and found to be fully compliant with the YEAR 2000 requirements. This is true for all models and revisions regardless of the date of manufacture or delivery. Users who wish to independently verify that specific products are in compliance may contact ADTRAN Technical Support at 1-888-423-8726. vi
Resumen del contenido incluido en la página 7
FEDERAL COMMUNICATIONS COMMISSION RADIO FREQUENCY INTERFERENCE STATEMENT This equipment has been tested and found to comply with the limits for a Class A dig- ital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio fre- quency energy and, if not installed and used in accordance with the instruction m
Resumen del contenido incluido en la página 8
CANADIAN EQUIPMENT LIMITATIONS Notice: The Canadian Industry and Science Canada label identifies certified equip- ment. This certification means that the equipment meets certain telecommunications network protective, operational, and safety requirements. The Department does not guarantee the equipment will operate to the user’s satisfaction. Before installing this equipment, users should ensure that it is permissible to be con- nected to the facilities of the local telecommunications compan
Resumen del contenido incluido en la página 9
Table of Contents Chapter 1. Introduction..................................................................................................... 1-1 Product Overview ...............................................................................................................1-1 T3 Overview ......................................................................................................................... 1-2 SNMP ..............................................................................
Resumen del contenido incluido en la página 10
Table of Contents Line Length ................................................................................................................... 3-3 DS3 Timing.................................................................................................................... 3-3 DS3 Scrambler............................................................................................................... 3-4 Data Link ................................................................................
Resumen del contenido incluido en la página 11
Table of Contents Port Status ..................................................................................................................... 4-5 Bandwidth ..................................................................................................................... 4-6 DTE Leads ..................................................................................................................... 4-6 Chapter 5. Statistics...............................................................
Resumen del contenido incluido en la página 12
Table of Contents xii T3SU 300 User Manual 61200217L1-1
Resumen del contenido incluido en la página 13
List of Figures Figure 2-1. T3SU 300 Rear View ....................................................................................... 2-4 Figure 2-2. T3SU 300 Front Panel...................................................................................... 2-6 Figure 2-3. Terminal Main Menu...................................................................................... 2-7 Figure 3-1. Configuration Main Menu ............................................................................ 3-2
Resumen del contenido incluido en la página 14
List of Figures Figure 6-4. Line Loopback Test.......................................................................................... 6-4 Figure 6-5. DTE Port Diagnostics Menu........................................................................... 6-5 Figure 6-6. Payload Loopback Test ................................................................................... 6-6 Figure 6-7. Payload BERT Test...........................................................................................
Resumen del contenido incluido en la página 15
List of Tables Table 3-1. Near End Alarm Trap Descriptions ............................................................. 3-16 Table 3-2. Far End Alarm Trap Descriptions .............................................................. 3-16 Table 3-3. MIB II Standard Trap Descriptions .............................................................. 3-17 Table 3-4. Network Test Trap Descriptions................................................................... 3-17 Table 3-5. DTE Port Trap Descriptio
Resumen del contenido incluido en la página 16
List of Tables xvi T3SU 300 User Manual 61200217L1-1
Resumen del contenido incluido en la página 17
Chapter 1 Introduction PRODUCT OVERVIEW The T3SU 300 is a multiport DSU/CSU (data service unit/channel service unit) that provides access to T3 services. The unit provides a cost-effective, versatile approach for migrating T1 services to T3. The TDM (time division multiplexer) multiport design allows you to share the cost of a T3 line between multiple applications. This unit maximizes the use of T3 services, providing up to four data ports capable of transmitting and receiving high-capacit
Resumen del contenido incluido en la página 18
Chapter 1. Introduction link, or through the built-in V.34 modem (1200217L2 only). Advanced dial-out on trap capabilities through the built-in modem allow the T3SU 300 to contact remote hosts and alert them to DSX-3 network conditions (without dedicated management connections). The T3SU 300 is designed for either desktop use or installation in a 19-inch rack. The major features or the T3SU 300 are as follows: • Full feature multiport T3 DSU/CSU • Maximum of four user data ports (HSSI or
Resumen del contenido incluido en la página 19
Chapter 1. Introduction (LAN) port. The T3SU 300 supports the MIB-II standard, RFC 1213, and the ADTRAN Enterprise Specific MIB. MIB files are available from ADTRAN in the support section of the ADTRAN Web page at www.adtran.com. The term SNMP broadly refers to the message protocols used to exchange information between the network management system (NMS) and the managed devices, as well as to the structure of device management databases. SNMP has three basic components: Network Manager C
Resumen del contenido incluido en la página 20
Chapter 1. Introduction INTERFACE OPTION CARDS Optional interface cards may be purchased to equip the T3SU 300 with up to three additional ports. Both HSSI and V.35 interface cards are available. HSSI Card The optional HSSI card plugs into one of the three card slots on the rear of the T3SU 300. With optional HSSI cards installed, the total 44.2 Mbps bandwidth of the T3 can be divided among the total number of ports to provide multiple data channels over the T3. The total bandwidth of the