Resumen del contenido incluido en la página 1
PWR / DDS
1102040L4
ACT
UBR1TE III
CR LP
B
2
B
1
Section 61102040L4-5B
Issue 2, January 2001
CLEI Code #5SC597IF_ _
SLC-5 U-BR1TE III w/PWR and DDS Loopbacks
ISDN 2B1Q Interface
Installation and Maintenance
CONTENTS
1. GENERAL .............................................................................. 1
2. INSTALLATION .................................................................... 3
3. TESTING ................................................................................ 8
4. MAINTENA
Resumen del contenido incluido en la página 2
transport of 2B+D information. Block error rate • Loopback release in response to TIPs generated performance over the T1 facility is monitored and is from the network direction per TR62310. available to the network. • Remap all subsequent DS0 DP loopback codes into respective eoc loopbacks to loopback The SLC-5 U-BR1TE III incorporates a feature that respective downstream U-Repeaters, TRISDN allows for detection of ISDN capable and non-ISDN elements, and U-BR1TES when optioned for capable SLC-5
Resumen del contenido incluido en la página 3
The U-BR1TE III will function with any ISDN 2B1Q U-interface that is ANSI T1.601 compliant. I 2B+D 2B+D Empty 2. INSTALLATION 12 3 C A U T I O N C A U T I O N ! SUBJECT TO ELECTROSTATIC DAMAGE Available OR DECREASE IN RELIABILITY. II 2B+D Empty for Other HANDLING PRECAUTIONS REQUIRED. Services 45 6 After unpacking the unit, inspect it for damage. If damage is noted, file a claim with the carrier, then contact ADTRAN. See Warranty and Customer Available Service. III for Other 2B+D Empty Ser
Resumen del contenido incluido en la página 4
Interface Requirements The U-BR1TE III unit includes two interfaces. The NOTE loop-side interface is an ISDN U-interface which is When the U-BR1TE III is optioned for B1 or B2, used to deliver Basic Rate service. The carrier-side the SLC-2000 slot must be provisioned for D interface is a SLC-5 or SLC-2000 channel bank only. If the U-BR1TE III is optioned for 2B, interface which is used to insert data into the 1.544 then the SLC-2000 slot must be provisioned for Mbps T1 stream. Only the polarit
Resumen del contenido incluido en la página 5
Table 2. Internal Switch Option Settings Sl witchLn abeFn unctio Descriptio SW1-1 B1Se ervice Level Selection Selects the service level. The U-BR1TE III may b SW1-2 B2 optioned to deliver full ISDN (2B+D) or any of the SW1-3 D following levels of service. Service SW1-1 SW1-2 SW1-3 Service Type O OOn OOn p p p p pt t t t tiiiiio o o o on n n (() ( (() B B B B B1 1 1 1 1) ) ) (() ( (() B B B B B2 2 2 2 2) ) ) () ( (() (D D D D D) ) ) ID SDN *n 2B+ OnOn O LB eased (128 kbps) 2nOnOf Of ID SDN/ DDS
Resumen del contenido incluido en la página 6
Figure 5 displays the position switch settings at ISDN network locations. SLC-5 SLC-5 COT RT 2-Wire 2-Wire L L Loop T Carrier U U Customer N L NT1 T T Note: Channel Channel Refer to Table 2 for switch Bank Bank function descriptions. Adjacent Adjacent to Customer (Source) to Switch SW2- SW2- 1 - LUNT (COT) 1 - LULT (RT) 2 - ADJ 2 - ADJ SW1- SW1- 5 - OFF 5 - OFF D4/SLC- 96 D4/SLC-96 SLC-5 SLC-5 2-Wire COT RT COT RT 2-Wire 2-Wire Loop L T Carrier L L
Resumen del contenido incluido en la página 7
Figure 6 displays the position switch settings at IDSL/DDS network locations. SLC 5 AB 4W 2-Wire Digital C D E Local 4W DS0 DP 4W DS0 DP Loop T1 T1 Customer 4W DS0-DP U-BR1TE or or IDSL OCU-R 1 Premises or DCS 1B OCU DP DCS COT RT D4 D4 SW2- 1 - LULT 2 - ADJ SW1- 1 - B1 2 - OFF 3 - OFF 4 - OFF 5 - PWR Non-ADTRAN U-BR1TE 1B+D A 2-Wire 2W BC DE Local 4W DS0 DP Digital Loop T1 U-BR1TE U-BR1TE or T1 U-BR1TE Customer IDSL OCU-R 2 1B 1B+D OCU DP Premises 1B+D COT D4 RT D4 1102040L4 Equip
Resumen del contenido incluido en la página 8
Front Panel Features When used in B1 configuration (non-D channel modes The RJ-45 jack allows front panel test access for local of operation) the U-BR1TE III will respond to an in- or downstream loopbacks. The address select knob band DS0 DP latching loopback sequence. When (SW3) determines which element is being looped remote testing is not available, or during back. Table 3 lists the loopback options. troubleshooting, the U-BR1TE III front panel provides local test capabilities for use with
Resumen del contenido incluido en la página 9
To initiate a point-to-point test, perform the Local Loopback following: The U-BR1TE III incorporates a special test mode to provide a local 2B+D bilateral loopback. Once 1. Connect the DS0 digital tester to the RJ-45 jack. invoked, this test allows an upstream and downstream 2. Configure the test set for Near Logic and 64kbps. test set to send a straight-away test pattern. To put the 3. Select the desired test direction and bearer U-BR1TE III into this test mode, select ADR7 on the channel u
Resumen del contenido incluido en la página 10
When the U-BR1TE III operation is normal, the of the U-interface between the LULT and the NT1. ADR7 position of SW1 does not have a function. Performance Monitoring TR829 The U-BR1TE III supports performance monitoring remotely from the ISDN switch. NOTE This test option is only available on power up of IDSL/DDS Description the U-BR1TE III. The U-BR1TE III may be deployed in the adjacent to customer mode to provide transport for DDS/Frame Relay services with an ADTRAN IDSL OCU-R. This I
Resumen del contenido incluido en la página 11
DS0 DP Loopback eoc Remapping 3. Minimum of 100 loopback enable (LBE) bytes Upon receipt of subsequent DS0 DP loopback codes (X1010110). when the D channel is disabled, the U-BR1TE III 4. Minimum of 32 far-end voice (FEV) bytes remaps the subsequent DS0 DP loopback sequences (X1011010). into the respective ISDN eoc loopback messages. This capability will permit all downstream ISDN D If the U-interface of the U-BR1TE III is not in sync, channel enabled U-BR1TEs, U-Repeaters, and the unit transmit
Resumen del contenido incluido en la página 12
Remote End Initiated LBK Tests If errors exist the loopbacks can help determine the The U-BR1TE supports loopbacks generated from source; either the local loop or the IDSL OCU-R. the IDSL OCU-R which allow testing to be performed During a remote end initiated loopback the IDSL/DDS without coordination with the CO or test center. system transmits ASC 9Eh towards the network, Loopbacks initiated by the OCU-R front panel LBK indicating an out-of-service condition generated by the pushbutton, aid i
Resumen del contenido incluido en la página 13
IDSL/DDS Trouble Code Contact Customer and Product Service (CAPS) prior The IDSL/DDS system provides a quick diagnosis in to returning equipment to ADTRAN. the case of a circuit condition where continuity is For service, CAPS requests, or further information, broken. The trouble code type received by a tester contact one of the following numbers: determines whether the open condition is occurring on the local loop or at the customer premises. In the ADTRAN Sales event of a 2-wire DSL loss of s
Resumen del contenido incluido en la página 14
14 Section 61102040L4-5, Issue 2 61102040L4-5B