Resumen del contenido incluido en la página 1
® ™ ®
Hotwire ReachDSL v1 (MVL ) Modem,
Model 6310-A4, with Inline Phone Filter
Installation Instructions
Document Number 6310-A2-GN12-00
September 2001
Contents
Hotwire 6310 ReachDSL v1 (MVL) Modem Overview .................................. 1
Getting Started .............................................................................................. 4
Installing the Hotwire 6310 ReachDSL v1 Modem ....................................... 5
Power-On ..........................................
Resumen del contenido incluido en la página 2
In addition, the ReachDSL v1 technology: Transforms a single copper pair into multiple virtual lines to support multiple services simultaneously. Supports simultaneous multiple access of four ReachDSL v1 modems with up to 254 end-user systems sharing one common WAN interface. Features HomeLink, which provides peer-to-peer communications, including print and file sharing applications (see HomeLink (for ReachDSL v1 Modems Only) on page 10). Hotwire ReachDSL System Copper pairs run from
Resumen del contenido incluido en la página 3
POWER ETHERNET PHONE LINE PHONE LINE POWER ETHERNET Phone Filter Depending on the type of phone handset and the quality of the home or business wiring, a phone filter is recommended to minimize background noise during a phone conversation. An internal phone filter is included with the Hotwire 6310 ReachDSL v1 Modem. If additional telephones are used on the same phone line as the ReachDSL modem, install one phone filter on each telephone. There are two Hotwire phone filters: Hotwire 6035
Resumen del contenido incluido en la página 4
Getting Started Before beginning your modem’s installation, make sure that you have all the equipment that you need. Package Checklist Verify that your package contains the following: ❑ Hotwire 6310 ReachDSL v1 Modem ❑ DSL interface cable with RJ11 connectors ❑ Power cord with power transformer Be sure to register your warranty at www.paradyne.com/warranty. Wiring and Cables You Need The following wiring and standard connectors are used with this product: ❑ Standard RJ11 (or RJ14) wall jack for
Resumen del contenido incluido en la página 5
POWER ETHERNET PHONE LINE Installing the Hotwire 6310 ReachDSL v1 Modem Place the ReachDSL modem on a flat surface with clearance for the rear connectors. Procedure 1. If a telephone is connected at the RJ11 RJ11 wall jack where the modem will be installed, Wall Jack unplug the telephone line from the wall jack. 2. Connect a telephone to the modem. (Optional – go to Step 3 if you are not connecting a telephone to the ReachDSL modem.) Plug the existing telephone interface cable 01-1701
Resumen del contenido incluido en la página 6
POWER ETHERNET PHONE LINE POWER ETHERNET PHONE LINE 4. Use an 8-pin Ethernet cable for the Ethernet connection. Insert one end of the cable into the jack labeled ETHERNET. — Use a straight-through cable and connect the other end to an Ethernet hub. (To connect to a hub’s Uplink connection, use an Ethernet crossover cable). Ethernet Line Ethernet Hub Ethernet Straight-Through Cable 01-17008 –or– — Use an Ethernet crossover cable and connect the other end to a PC with an Ethernet Network Int
Resumen del contenido incluido en la página 7
PHONE LINE POWER ETHERNET 5. Insert the supplied power cord’s round end into the jack labeled POWER. Plug the transformer into an AC outlet. Power Jack Transformer or 01-17010 The ReachDSL modem hardware installation is now complete. When the power cord is installed, the ReachDSL modem goes through a power-on self-test. 7
Resumen del contenido incluido en la página 8
Power-On When power is applied, the ReachDSL modem performs self-diagnostics and the PWR LED is on. The self-diagnostics includes a power-on self-test and all of the LEDs turn on for one second. Power – green Alarm – red Test – yellow DSL Line – green Transmit/Receive – green Ethernet Link – green PWR ALM TST LINE TX/RX ETHERNET ReachDSL 01-17003 Status LEDs All of the LEDs turn on and off during the power-on self-test. After a successful self-test, the LEDs should appear as indicated in BO
Resumen del contenido incluido en la página 9
Troubleshooting LED Symptom Action All LEDs are on. If LEDs remain on after ten minutes, the modem is not functional. Contact the service provider. ALM LED remains The power-on self-test may have failed. Unplug the unit and on. reapply power. If the alarm LED is still on, contact the service provider. ALM and TST LEDs Firmware download may be in progress. If firmware download is are blinking. not in progress or the LEDs continue blinking after ten minutes, contact the service provider. Ethe
Resumen del contenido incluido en la página 10
PHONE LINE POWER ETHERNET POWER ETHERNET PHONE LINE To improve data transmission throughput and minimize background noise during a telephone conversation, make sure that: The Hotwire 6310 ReachDSL v1 Modem is always powered on, even when not in use, and A Hotwire phone filter is installed on every telephone on the same line as the Hotwire 6310 ReachDSL v1 Modem (see Phone Filter on page 3). HomeLink (for ReachDSL v1 Modems Only) HomeLink is a feature that provides peer-to-peer communica
Resumen del contenido incluido en la página 11
Cables & Connectors This section is reference information. Standard twisted-pair CAT3 or better cables are recommended. The LINE and PHONE interface connectors use 6-pin, non-keyed modular plugs. RJ11 or RJ14 6-pin connectors can be used. 6-Pin RJ11 Plugs Line & Phone Connectors Pin # Function 1 Not used 2 Ring 2 (optional) 3 DSL Ring 1 Pin #6 4DSL Tip 1 Pin #1 5 Tip 2 (optional) 6 Not used 98-15304a The LINE and PHONE jack pinouts are either filtered or unfiltered for POTS. PHONE Jack P
Resumen del contenido incluido en la página 12
The Ethernet interface connector uses an 8-pin, non-keyed modular plug. — To connect the ReachDSL modem to an Ethernet hub, use the straight-through connection. Ethernet Cable 8-Pin Straight-through Connection Pin # Function 1 10BaseT TX D+ 8-Pin 2 10BaseT TX D– Plug 3 10BaseT RX D+ 4 & 5 Not used 6 10BaseT RX D– Pin #8 7 & 8 Not used Pin #1 98-16055a –or– — To connect the ReachDSL modem directly to a PC with an Ethernet NIC card, use an Ethernet crossover cable. 8-Pin Ethernet Crossover
Resumen del contenido incluido en la página 13
Optional ReachDSL Modem Wall Placement The Hotwire 6310 ReachDSL v1 Modem is designed for tabletop placement. The ReachDSL modem can also be mounted on a wall. To mount the modem, you will need: ❑ Two slotted-head #6 self-threading screws with plastic anchors ❑ Drill and 3/16" drill bit for the plastic anchors ❑ Screwdriver A template with the dimensions for the two screws is provided. See ReachDSL Modem Hardware Template on page 14. Procedure To mount the Hotwire 6310 ReachDSL v1 Modem: 1.
Resumen del contenido incluido en la página 14
ReachDSL Modem Hardware Template 01-17014 14 Top 5.10 Bottom
Resumen del contenido incluido en la página 15
Technical Specifications for Hotwire 6310 ReachDSL v1 Modem Item Specification* Height x Width x Depth 1.46" x 5.72" x 4.33" (3.71 cm x 14.54 cm x 11.00 cm) 0.45 lb. (0.20 kg) Weight Power Class 2 Transformer normal Input: 100 VAC (+10%), 50 Hz; service input voltage range 120 VAC (+10%), 60 Hz; or 230 VAC (+10%), 50/60 Hz Output: 5 VDC nominal, minimum 0.6A (SELV) Approvals FCC Part 15 Class B digital device CISPR 22 Class B Other Certifications Refer to equipment’s label for approvals on pr
Resumen del contenido incluido en la página 16
! Important Safety Instructions 1. Read and follow all warning notices and instructions marked on the product or included in the manual. 2. Slots and openings in the cabinet are provided for ventilation. To ensure reliable operation of the product and to protect it from overheating, these slots and openings must not be blocked or covered. 3. Do not allow anything to rest on the power cord and do not locate the product where persons will walk on the power cord. 4. Do not attempt to service t
Resumen del contenido incluido en la página 17
CE Marking When the product is marked with the CE mark on the equipment label, this demonstrates full compliance with the following European Directives: Directive 73/23/EEC – Council Directive of 19 February 1973 on the harmonization of the laws of the member states relating to electrical equipment designed for use within states relating to electrical equipment designed for use within certain voltage limits, as amended by Directive 93/68/EEC. Directive 89/336/EEC – Council Directive of 3
Resumen del contenido incluido en la página 18
Declaration of Conformity This Declaration of Conformity is made by Paradyne Corporation pursuant to Parts 2 and 15 of the Federal Communications Commission’s Rules. This compliance information statement pertains to the following products: Trade Name: Hotwire Model Number: 6310-A4-200 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference re
Resumen del contenido incluido en la página 19
Government Requirements Certain governments require that instructions pertaining to connection to the telephone network be included in the installation and operation manual. Specific instructions are listed in the following sections. United States – Notice to Users of the Telephone Network 1. This equipment complies with Part 68 of the FCC rules. On the equipment is a label that contains, among other information, the FCC registration number and Ringer Equivalence Number (REN) for this equipm
Resumen del contenido incluido en la página 20
8. This equipment cannot be used on public coin service provided by the telephone company. Connection to Party Line Service is subject to state tariffs. (Contact the state public utility commission, public service commission or corporation commission for information.) 9. An FCC compliant telephone cord with modular plugs may be provided with this equipment. This equipment is designed to be connected to the telephone network or premises wiring using a compatible modular jack which is Part 6