Resumen del contenido incluido en la página 1
Pub. 988-0154-641
EP-90R Pressure
Electronic Sensor
Installation and Configuration Instructions
This document shows how to install an EP-90R Pressure sensor and
®
how to connect it to a NMEA 2000 network. It also provides
instructions on how to configure your pressure sensor with Lowrance
digital gauges (LMF-200 & LMF-400) and display units.
NMEA 2000 is the communication bus standard developed by the
National Marine Electronics Association (NMEA) for use in boats.
Lowrance has intro
Resumen del contenido incluido en la página 2
The EP-90R consists of a red cable connector and the EP-90R housing with standard size hose barb attachment. The EP-90R Water Pressure sensor, like the other LowranceNet Electronic Probe (EP) sensors, is designed for use with a NMEA 2000 DeviceNet Network. Your sensor, however, is also compatible with LowranceNet blue connector networks. It can be added to a blue connector network by using a red female to blue female adapter cable. Your sensor MUST be connected to a NMEA 2000 network or
Resumen del contenido incluido en la página 3
For complete instructions on setting up a new NMEA 2000 network or expanding an existing one, see the other document packed with your EP-90R, "Setup and Installation of NMEA 2000 Networks, General Information" part number 988-0154-173. If that document is not available, it can be downloaded free from the Lowrance web site. Installation The EP-90R Pressure sensor can provide pressure data for the following categories: Atmospheric Pressure, Engine Boost Pressure, Engine Oil Pressure, Engin
Resumen del contenido incluido en la página 4
3. Slide the pressure hose onto the EP-90R hose barb attachment. If it does not fit snugly, secure it with a zip tie at the base of the hose barb attachment. 4. Now you are ready to remove the speedometer. Refer to the speedometer’s installation manual for removal instructions. 5. The EP-90R is ready to be connected to NMEA 2000 network. If the NMEA 2000 network backbone is in another part of the boat, the EP- 90R can be linked to the display unit at the console — if one is present — or
Resumen del contenido incluido en la página 5
In similar fashion, a NMEA 2000 network allows multiple display units to receive data from a GPS antenna or multiple sonar units to receive messages sent from a temperature sensor. A NMEA 2000 network gives you the flexibility to view information like, engine diagnostics and fuel level data on digital gauges or display units located anywhere on your boat. There are two types of LowranceNet red connectors: the single T connector (left) and the double T connector (right). Network B
Resumen del contenido incluido en la página 6
Backbone cable Terminator at (to rest of bus) Double T the end of the connector Cable from backbone (bus) sensor or display unit Cap for unused connector NMEA 2000 network node located at the end of a NMEA 2000 backbone. NOTE: If you have a double T Connector on your network that is not attached to a device, you must cap the unused connector with a NMEA 2000 cap. This will protect the pin connectors from corrosion. The NMEA 2000 cap looks like a terminator, but has "Cap" s
Resumen del contenido incluido en la página 7
Use T-connector or double T connector to add Backbone cable device to bus (maintaining linear architecture) to rest of bus Existing network node Attach terminator at end of bus Devices connect to double T connector In this example, a new device is added to the NMEA 2000 bus by installing a T connector between a T connector and a terminator at the end of the backbone (network bus). Additional Network Information For more information on creating or expanding a network refer to
Resumen del contenido incluido en la página 8
Notes 8
Resumen del contenido incluido en la página 9
LMF-200: EP-90R Pressure Configuration This section covers how to use EP-90R Pressure Sensor with the LMF- 200 Multi-function gauge. NOTE: You will notice the LMF-200 does not have an Exit key. Menus will time out after a preset amount of time (3, 5, 10 or 15 seconds). The default setting is 5 seconds. Refer to your LMF-200 instruction manual for more information on the Timeout feature. LMF-200 Multi-function Digital Gauge. Boat Setup If this is the first time you have turned on you
Resumen del contenido incluido en la página 10
4. Use the UP and DOWN keys to input the number of gallons the tank will hold and press MENU. Repeat steps 3 and 4 for each additional tank. After all tanks have been set up, you will be directed to the main display. Boat Setup Reset If you want to access the Setup screen (Boat Setup) after an engine- tank configuration has been chosen you will have to reset the configuration to default settings. To reset engine tank configuration: 1. Press MENU, highlight SYSTEM SETUP and press MENU.
Resumen del contenido incluido en la página 11
To unconfigure the EP-90R: 1. Press MENU, select SYSTEM SETUP and press MENU. 2. Highlight BUS DEVICES and press MENU. Select a configured pressure sensor and press MENU. 3. The pressure sensor menu will appear. Highlight UNCONFIG and press MENU. The following message will appear: Hit Menu to Unset Dev Name. 4. Press MENU. You will be taken back to the Bus Devices list. To reconfigure the EP-90R: 1. Press MENU, select SYSTEM SETUP and press MENU. 2. Highlight BUS DEVICES and press M
Resumen del contenido incluido en la página 12
Adding a page: 1. Press MENU, use the UP and DOWN keys to select PAGES and press MENU, which will open the Pages menu with the following options: Add Page, Rem Page, Autoscroll and Set Pop-up. 2. Highlight ADD PAGE and press MENU. 3. Select Gauge, Single Digital or Dual Digital and press MENU. You will be taken back to the main display, where the page you selected will be shown. Customizing Pages The customizing pages feature allows you to choose what data will be displayed and where
Resumen del contenido incluido en la página 13
up to three options. (If your unit is configured for one engine, or if you chose Pitot Speed or Atmospheric Pressure, you will be directed back to the main display.) 4. Select the desired engine and press MENU. You will be taken back to the main display. To customize Dual Digital page: 1. After the Dual Digital page has been added to the page screen rotation, use the UP and DOWN keys to display it on the screen. 2. Press MENU, select CUSTOMIZE and press MENU. The Position menu will app
Resumen del contenido incluido en la página 14
3. Select the desired option and press MENU. The Pressure Range menu will appear with the following options: 0-30 psi, 0-60 psi, 0-80 psi and 0-100 psi. 4. Select the desired PSI range and press MENU. Warning Threshold When you set a Warning Threshold for a pressure sensor, a pop-up window will appear and an alarm will sound when pressure exceeds a preset pressure level of your choosing. NOTE: Warning Thresholds may be set to monitor Boost Pressure, Engine Water Pressure, Oil Pressu
Resumen del contenido incluido en la página 15
LMF-400: EP-90R Pressure Configuration This section covers how to use your EP-90R Pressure Sensor with the LMF-400 Multi-function gauge. LMF-400 Multi-function Digital gauge. Boat Setup If this is the first time you have turned on your LMF-400, you will have to complete Boat Setup before you will be able to configure your water pressure sensor. To execute Boat Setup: 1. With Boat Setup highlighted on the screen, press ENTER. A menu will appear, allowing you to choose the number of
Resumen del contenido incluido en la página 16
5. After all tanks on your vessel have been set up, press EXIT repeatedly to return to the main display. Boat Setup Reset If you want to access the Setup screen (Boat Setup) after an engine- tank configuration has been chosen you will have to reset the configuration to default settings. To reset engine-tank configuration: 1. Press MENU, highlight SYSTEM SETUP and press ENTER. 2. Choose ENG/TANK CFG and press ENTER twice. The following message will appear: Press ENTER to reset Eng/Tnk C
Resumen del contenido incluido en la página 17
4. Press ENTER. You will be taken back to the Bus Devices list. Press EXIT repeatedly to return to the main display. To reconfigure the EP-90R: 1. Press MENU, select SYSTEM SETUP and press ENTER. 2. Highlight BUS DEVICES and press ENTER. Select a configured pressure sensor and press ENTER. 3. Highlight RECONFIGURE and press ENTER. 4. Select the PITOT SPEED, ENG BST PRESS, ENG OIL PRESS, ENG WTR PRESS, FUEL PRESSURE, TRNS OIL PRESS or ATM PRESSURE and press ENTER. The Select Engine men
Resumen del contenido incluido en la página 18
Customizing Pages The customizing pages feature allows you to choose what data will be displayed on selected pages. You can use the Single Analog, Dual Analog, Quad Analog, Single Digital, Dual Digital, Quad Digital pages and Fuel Manager pages to display pressure sensor data. To customize Single Analog page: 1. Make sure the Single Analog page has been added to the page screen rotation. 2. Use the ENTER and EXIT keys to scroll the Single Analog page onto the main display. 3. Press M
Resumen del contenido incluido en la página 19
To customize Quad Analog page: 1. Make sure the Quad Analog page has been added to the page screen rotation. 2. Use the ENTER and EXIT keys to scroll the Quad Analog page onto the main display. 3. Press MENU, select CUSTOMIZE and press ENTER. The Position menu will appear with four options: Top Left, Top Right, Bottom Left and Bottom Right. 4. Select the desired position and press ENTER. The data menu will appear. 5. Highlight PITOT SPEED, ENG BST PRESS, ENG OIL PRESS, ENG WTR PRESS,
Resumen del contenido incluido en la página 20
5. Highlight PITOT SPEED, ENG BST PRESS, ENG OIL PRESS, ENG WTR PRESS, FUEL PRESSURE, TRNS OIL PRESS or ATM PRESSURE and press ENTER. The Select Engine menu will appear with up to three options. (If your unit is set to a single-engine configuration, or if you chose Pitot Speed or ATM Pressure, you will be taken back to the Position menu.) 6. Select the desired engine and press ENTER. You will be directed to the Position menu. 7. Repeat steps 4-6 to customize the other position or press E