Resumen del contenido incluido en la página 1
OWNER’S
INSTRUCTIONS
AW0529
PORTABLE-TYPE
ROOM AIR CONDITIONER
( Cool )
E S
DB68-30824B(3)
Resumen del contenido incluido en la página 2
Safety Precautions The following safety precautions must be taken when using your air conditioner. 1 The power supply must be from an independent circuit. The air conditioner shall be installed in accordance with national wiring regulations and safety regulations wherever applicable. 2 Some installation locations may require installation of a short circuit breaker or grounding 3 If the supply cord is damaged, it must be replaced by a special cord or assembly available from the manufa
Resumen del contenido incluido en la página 3
Contents PREPARING YOUR AIR CONDITIONER Safety Precautions ......................................................................................... 2 Description of Each Component .................................................................... 4 Getting Started ............................................................................................... 5 OPERATING YOUR AIR CONDITIONER Cooling Your Room .........................................................................
Resumen del contenido incluido en la página 4
Description of Each Component Air outlet Air flow direction adjustable blades Air filter Control panel (The air filter is located inside) Window Air inlet (Inside) filler panel Air inlet (Outside) Power plug (Be sure to check the voltage before installation. - Refer to page 12) CONTROL PANEL 6 OFF LOW LOW 4 8 FAN COOL 2 10 HI HI FAN COOL 12 COOLEST Thermostat control Master control E-4
Resumen del contenido incluido en la página 5
Getting Started You have just purchased a portable-type room air conditioner which should be installed according to your Owner’s Instructions. Your Owner's Instructions contain much valuable information on using your air conditioner. Please take the time to read them as they will help you take full advantage of the unit's features. The booklet is organized as follows: The following figure is shown on page 4. - Unit It will help you find the controllers and understand the symbols displayed.
Resumen del contenido incluido en la página 6
Cooling Your Room You must select the COOL mode if you wish to adjust the: Cooling temperature Fan speed when Cooling 1 Turn the MASTER CONTROL, OFF LOW and set it to “ HI COOL ” or “ LOW COOL ”. LOW FAN COOL Result: The air conditioner starts up in cool mode. N N N No o o otttte e e e HI COOL : The fan turns rapidly. HI HI FAN COOL LOW COOL : The fan turns slowly. You can change modes at any time. 2 Turn the thermostat control to the desired position. 81˚F ~ 73˚F 6 Possible temper
Resumen del contenido incluido en la página 7
Airing Your Room If the atmosphere in your room is stale, you can air the room using the Fan feature. 1 Turn the MASTER CONTROL, and set it to “ HI FAN ” or “ LOW FAN ”. OFF LOW LOW FAN COOL Result: The air conditioner starts up in fan mode. N No otte e HI FAN : The fan turns rapidly. N No otte e LOW FAN : The fan turns slowly. HI HI FAN COOL You can change modes at any time. To control the direction of the air flow, refer to below. 2 Adjusting the Air Flow Direction Vertically The air
Resumen del contenido incluido en la página 8
Power Failure Here are a few recommendations that you should follow when using your air conditioner. T If oa pic power R failure occurs ecommendation while the air conditioner is operating, it is switched off. When the power returns, the air conditioner restarts. Temperature and Humidity Range The following table indicates the temperature and humidity ranges within which the air conditioner can be used. If the air conditioner is used at... Then... Higher temperature The auto
Resumen del contenido incluido en la página 9
Cleaning Your Air Conditioner Be sure to clean the air filter periodically to maintain the air conditioner in the best condition for a long period time. When cleaning the air conditioner, be sure to stop IMPORTANT operation of the system, and pull out the power plug. Hold the handle of the air filter and slide it up. 1 2 Remove the dust on the air filter using a vacuum cleaner and brush. 3 Insert the air filter into the original position. 4 Wipe the surface of the unit with neutral detergent a
Resumen del contenido incluido en la página 10
Solving Common Problems Before contacting the after-sales service, perform the following simple checks. They may save you the time and the expense of an unnecessary call. Problem Explanation / Solution Check for any power failure. The air conditioner does not operate at all. Check the voltage. (See the technical specifications) Check the power plug for disconnection. Check to see whether the MASTER CONTROL is placed in "OFF " position. (Set it to the desired position.) Check to se
Resumen del contenido incluido en la página 11
Technical Specifications Power Supply Cooling Dimensions Net Weight Capacity (W X H X D) 115V, 60Hz 492 X 365 X 316 21kg 5,000 BTU/h (mm) Design and specifications are subject to change without notice. E-11
Resumen del contenido incluido en la página 12
Installation Before installation, be sure to check the installation area for the air conditioner, and drain hose. Checkpoints prior to installation 1 Check the cabinet and front grille of the unit for any harmful defects such as scratches. 2 Be sure to check the power supply. - Refer to the specifications on the label attached to the unit. Installation instructions 1 Electrical Requirements For personal safety: This appliance must be properly grounded. Do not, under any circumstances, cut
Resumen del contenido incluido en la página 13
Installation of the Drain system. The unit does not require any separate drain system. However, a separate drain tube can be installed if necessary. Cooling capacity Noise Drain system installed Decrease Decrease Without drain system installed Increase Increase The procedure for installing the drain tube should be determined by the conditions of the installing area. 1 Remove the rubber cap inserted into the base. 2 Insert the drain tube as show in the figure, and then connect the drain hose. (Y
Resumen del contenido incluido en la página 14
Installation (Cont.) Window installation Tools needed Philips head screw driver Ruler or tape measure Adjustable wrench Pencil Scissors Leveler Parts furnished Type Name of part Q’ty Type Name of part Q’ty Long wood screw (5X16) Adhesive seal strip A F 10 1 Screw (4X16) Window gasket B G 4 1 Window filler panel (Right) Window filler panel clamp C H 2 1 Window filler panel (Left) Window filler panel clamp D I 2 1 E “L” Bracket 2 1 Installation of the “L” bracket. 1-1 Meas
Resumen del contenido incluido en la página 15
3 Attach the seal strip to the window. 3-1 Cut the adhesive-backed foam seal strip gasket to the window width. 3-2 Remove the backing from the seal strip and attach the strip to the underside of the bottom window. 4 Install the unit in the window. 4-1 Lift unit into center of opened window. Use hand grips on top sides of unit as an aid in lifting and positioning unit. 4-2 Rest bottom of unit against outside edge of inner window sill. Be sure bottom edge of unit fits down into “L” bracket
Resumen del contenido incluido en la página 16
YOUR SAMSUNG ROOM AIR CONDITIONER WARRANTY Limited Warranty to Original Purchaser Samsung will repair or replace, at our option, this product if found defective within the warranty period beginning from the original date of purchase. This Samsung Product is warranted by SAMSUNG ELECTRONICS America Inc. against manufacturing defects in materials or workmanship for the period specified. Labor Parts 1 Year (Carry in) 1 Year Limited 5-Years Compressor Warranty Within one year of purchase Samsung El