Resumen del contenido incluido en la página 1
Blue Star C500 Static Single-phase Watt-hour Meter – IEC 61036 (1.0S)
IEC 61036
IEC 1107
C500 Single-Phase Watt-hour Meter
Product Description
Operating Instructions
Features and Technical Data
Maintenance Instructions
Diagrams and Figures
Nanjing Blue Star Electrical Meter Research Institute
181 Hanzhongmen Street
Nanjing 210036, China
International Sales Tel: 86-25-86504148
Fax: 86-25-86601945
www.bluestarmeters.com
sales@bluestarmet
Resumen del contenido incluido en la página 2
Blue Star C500 Static Single-phase Watt-hour Meter – IEC 61036 (1.0S) TABLE OF CONTENTS 1. Features and Applications............................................................................................................3 1.1 Energy Metering..............................................................................................................3 1.2 1.2 Data displaying .........................................................................................................3 1.3 1
Resumen del contenido incluido en la página 3
Blue Star C500 Static Single-phase Watt-hour Meter – IEC 61036 (1.0S) 1. Features and Applications Blue Star’s C500 watt-hour meter meets the IEC 61036 (class 1.0S) standard for energy meters. The main features of C500 include none physical adjustment components, digital signal processing, digital filters, digital error correction, digital calibration, immunity to temperature fluctuation, and excellent stability. Due to its 12 times overload multiplier, A0 can record energy usage of e
Resumen del contenido incluido en la página 4
Blue Star C500 Static Single-phase Watt-hour Meter – IEC 61036 (1.0S) There are 2 modes after data processing unit powers up: 1. Running Mode: In this mode, B500 meter can perform TOU metering, demand calculating and load monitoring, and automatically display data at given time as programmed. 2. Programming mode: A0 will switch to this mode after holding reset button for 8 seconds. In this mode, LCD will display message “PRG”. It will only process energy counting, demand calculating and t
Resumen del contenido incluido en la página 5
Blue Star C500 Static Single-phase Watt-hour Meter – IEC 61036 (1.0S) 2.2 Programming B500 can be programmed (namely parameter setting) through infrared port with handheld unit. 2.2.1 Password Password is needed to program B500, reading does not need password. Password can not be modified. Password is set as “666666”, please keep it at the safety place. Page 5 1/26/2005 Rev 1.0.01
Resumen del contenido incluido en la página 6
Blue Star C500 Static Single-phase Watt-hour Meter – IEC 61036 (1.0S) 3. Specifications and technical data 1.1 Specifications 1.2 Technical data 1.2.1 Power supply Power Current Power Meter type consumption (mA) (W) (VA) 220V <5 <1 <0.7 (transformer) 110V <4 <0.8 <0.5 (transformer) 4. Use, transportation and storage conditions Same requirements as indoor meters. The number of piling layers should not exceed five in original package. Moisture absorbent must b
Resumen del contenido incluido en la página 7
Blue Star C500 Static Single-phase Watt-hour Meter – IEC 61036 (1.0S) Appendix A: Warning and Error Information ERR 2 Error Info 0000 0001 Clock ‘s Oscillator Error 0000 0010 Read/Write Clock Error 0000 0100 Read/Write EEPROM Error 0000 1000 Read /Write Cs5460A Error 0001 0000 CPU Program Error 0010 0000 reserved 0100 0000 Low Battery Voltage 1000 0000 SPI Read or Write Error ERR 1 Warning Info 0000 0001 Over Voltage 0000 0010 Under Voltage 0000 0100 Pha
Resumen del contenido incluido en la página 8
Blue Star C500 Static Single-phase Watt-hour Meter – IEC 61036 (1.0S) Appendix B: Connect Figure 3 Phase 4 Wire Direct connection Connection through current transformer Connection through current transformer and voltage transformer Page 8 1/26/2005 Rev 1.0.01
Resumen del contenido incluido en la página 9
Blue Star C500 Static Single-phase Watt-hour Meter – IEC 61036 (1.0S) 3 Phase 3 Wire Direct connection Connection through current transformer Connection through current transformer and voltage transformer Output Define Page 9 1/26/2005 Rev 1.0.01
Resumen del contenido incluido en la página 10
Blue Star C500 Static Single-phase Watt-hour Meter – IEC 61036 (1.0S) NO.1 Pulse Output : Active import energy NO.2 Pulse Output : Active export energy NO.3 Pulse Output : Reactive import energy NO.4 Pulse Output : Reactive export energy RXD : PC send data to meter TXD : Meter send data to PC Page 10 1/26/2005 Rev 1.0.01