Resumen del contenido incluido en la página 1
834171 C 0811YZ
IS SERIES
Commercial & Security Video Intercom system
Local System
SETTING MANUAL
Thank you for selecting Aiphone for your communication and security needs. Please read this manual and the separate
“OPERATION MANUAL” carefully before setting and using this system.
* Refer to the provided “INSTALLATION MANUAL” for complete information regarding this system.
IMPORTANT
Please read and understand the system setting procedures before beginning the setup process.
Please note that
Resumen del contenido incluido en la página 2
CONTENTS Registering stations and PA outputs ABOUT THIS MANUAL ............... 3 to zones [System setting – PURPOSE OF THE SYSTEM Zone setting] ............................... 17 SETTINGS ................................... 3 Registering sound fi les for chime [Chime setting – Registering SETTING LIST ............................. 4 sound source] .............................. 17 STARTING UP THE SYSTEM ..... 8 Registering sound sequences [Chime setting – Registering System requirements for
Resumen del contenido incluido en la página 3
GETTING STARTED SETTING THE SYSTEM USING THE SYSTEM APPENDIX ABOUT THIS MANUAL The IS system provides various manuals to meet various system planning and work processes. Use the manuals necessary for your system. Manual confi gurations The following manuals are provided for a local system. Read all the manuals for installing, setting up, and using a local system, or provide the manuals to the persons working with the system. * The INSTALLATION MANUAL includes the contents for a standard (IP) sy
Resumen del contenido incluido en la página 4
SETTING LIST The following is the list of system settings you can make via the web browser. The titles or items in shaded cells are required. NOTE: The following list is a brief overview of the setting items available in the system settings on a PC. The descriptions, and the style and order of descriptions do not necessarily equate with the actual displays. Title Sub title Item Sub item Setting range Default (On the login - (Language) - English/French/German/Spanish/Dutch/ English window) Itali
Resumen del contenido incluido en la página 5
GETTING STARTED SETTING THE SYSTEM USING THE SYSTEM APPENDIX Title Sub title Item Sub item Setting range Default System setting Advanced station Video door Call priority Normal/Priority/Urgent Normal settings station/Audio Called stations (Set up to 20 master stations from the - door station/ registered ones.) Room sub Contact type Normally open (NO) Normally open station /Normally closed (NC) (NO) Call priority/Answering Answering the page Normal the page /Call (Normal/Priority/Urgent) Trans
Resumen del contenido incluido en la página 6
Title Sub title Item Sub item Setting range Default System setting Advanced station Room sub (Contact output L1 to L4 L1 settings control unit/ terminal) Add-on Contact type Normally open (NO)/Normally closed (NC) Normally open control unit (NO) Trigger condition None/Calling notice/Door release/PA None output Calling notice Normal: OFF/ON Normal: OFF (Only when "Calling Priority: OFF/ON Priority: OFF notice" is selected at Urgent: OFF/ON Urgent: OFF "Trigger condition") Door release (Select f
Resumen del contenido incluido en la página 7
GETTING STARTED SETTING THE SYSTEM USING THE SYSTEM APPENDIX Title Sub title Item Sub item Setting range Default Transfer setting Registering daily Schedule number - DT1/DT2 DT1 transfer schedule Schedule name - Up to 24 alphanumeric characters - Call transfer time - Hour: 0 to 23 - Minute: 0 to 59 (Set to the Start time and End time individually.) Transfer schedule Weekly schedule (Repeat setting) Every week/Every other week Every week setting Schedule start date From the current day to 1 year
Resumen del contenido incluido en la página 8
RJ45 STARTING UP THE SYSTEM Before making the system settings, confi rm that a PC is connected to the central control unit (IS-CCU). The system settings are made on the PC by accessing the web browser for the settings incorporated with the central control unit (IS-CCU). System requirements for PC Your PC and operating environment must meet the following system requirements to make the settings. Network 10BASE-T Ethernet, 100BASE-TX Ethernet Web browser Internet Explorer 6.0 or later (with Inter
Resumen del contenido incluido en la página 9
GETTING STARTED SETTING THE SYSTEM USING THE SYSTEM APPENDIX Press down the "I" side of POWER switch to turn on 2 Setting the system confi guration all the control units in the system. [System confi guration] After logging in to the system, the [System confi guration] POWER switch window appears. Press down "I" side to turn on the • unit. First of all, make the setting on this window before starting the Press down "O" side to turn off the • system settings. unit. Select your system between
Resumen del contenido incluido en la página 10
MAKING THE SYSTEM SETTINGS The basic setting procedure When you have logged in to the system, the setting window appears. You can make the settings on this window. * Make sure to refer to the on-screen instructions and comments displayed on each window when you make the settings. * Depending on the PC and its OS or environment, the display may differ. Setting contents display area The setting items of the selected setting title and their details are displayed here. Tem
Resumen del contenido incluido en la página 11
GETTING STARTED SETTING THE SYSTEM USING THE SYSTEM APPENDIX The following shows the setting procedure for the items of each title. Refer to “SETTING LIST” ( →P. 4-7) for details about the settings. Make the settings by also referring to the on-screen instructions. Making network settings [Network setting] Setting the administrator ID and password [Administrator setting] Make the settings for network according to your requirements. We recommend that you change the administrator ID and passw
Resumen del contenido incluido en la página 12
Registering areas Registering control units [System setting Required – Control units composition] [System setting – Area registration] Register all the control units connected to the central control Register areas for separating stations in the system. The unit. number to which a name is entered is registered as an area number. Up to 99 areas can be registered. Click Control units composition in the table of 1 Click Area registration in the table of contents. contents. 1 Enter an area n
Resumen del contenido incluido en la página 13
GETTING STARTED SETTING THE SYSTEM USING THE SYSTEM APPENDIX Station number Registering stations and PA outputs • Click to assign sequential numbers to all the checked [System setting – Registering stations] stations from top to bottom. The number you enter will Register all the stations and PA outputs connected in the be set as the fi rst number and will be assigned to the top system, and set the area, station no., station name (or PA station of the ones checked. Other checked stations wil
Resumen del contenido incluido en la página 14
Making detailed settings to stations and Making detailed settings to door stations or room sub stations control units [System setting – Advanced station settings] NOTE: Make the settings to door stations or room sub stations Make detailed settings for the registered stations and control respectively. You cannot select a video door station, audio door units. The settings can be made to a station or control unit station and a room sub station at the same time. individually, or multiple sta
Resumen del contenido incluido en la página 15
GETTING STARTED SETTING THE SYSTEM USING THE SYSTEM APPENDIX B Settings on [Contact input] window (for room Making detailed settings to master sub stations only) stations Make settings for contact input. [Contact type]: • The following setting item buttons are displayed in the “Advanced settings” window. Select either Normally open (NO) or Normally closed (NC). [Call priority/Answering the page]: • D You can select the action of the station when detecting input between ‘calling with appr
Resumen del contenido incluido en la página 16
[Sound source]: • Making detailed settings to the central control Select either [Internal sound source] or [External sound source] as the source of chime. When [Internal unit, add-on control unit(s) or room sub sound source] is selected, select a sound fi le or control unit(s) sequence from the registered ones in the list. (You need to register sound fi les and/or sound sequences in advance. ( →P. 17-18)) NOTE: When [External sound source] is selected, select Make the settings to the
Resumen del contenido incluido en la página 17
GETTING STARTED SETTING THE SYSTEM USING THE SYSTEM APPENDIX Registering stations and PA outputs to zones Registering sound fi les for chime [System setting – Zone setting] [Chime setting – Registering sound source] Assign stations and PA outputs to the registered zones. Register sound data as the source of each chime. Copy MP3- format sound fi les onto the PC in advance. (Only MP3 fi les can Click Zone setting in the table of contents. be registered in the system.) 1 * Up to 3MB of the total a
Resumen del contenido incluido en la página 18
Registering sound sequences Registering daily chime schedule [Chime setting – Registering sound sequences] [Chime setting – Registering daily chime schedule] Register sound sequences for chime. Up to 10 daily schedules can be registered. Click Registering daily chime schedule in the table * Up to 20 sequences can be registered. 1 of contents. Click Registering sound sequences in the table of 1 contents. [Schedule number]: 2 Select the schedule number to register the daily [Sound number]:
Resumen del contenido incluido en la página 19
GETTING STARTED SETTING THE SYSTEM USING THE SYSTEM APPENDIX H Settings on [Weekly schedule] setting window Setting chime schedule Select either [Every week] or [Every other week]. 1) [Chime setting – Chime schedule setting] Set the schedule start and end dates. 2) You can set a weekly chime schedule or individual daily * The monthly calendar is displayed by clicking schedule. Refer calendar and you can select the start and end dates. * The settings can be made to 1 year ahead. * If ne
Resumen del contenido incluido en la página 20
Registering daily transfer schedule Setting transfer schedule [Transfer setting – Registering daily [Transfer setting – Transfer schedule setting] transfer schedule] You can set a weekly transfer schedule and individual daily schedule. You can set the schedule for transferring calls to other master * stations automatically. The schedules registered on this setting The settings can be made 1 year ahead. are used when making a transfer setting on a master station. Click Transfer schedule setti