INSTALLATION INSTRUCTIONS
UFM
Universal Flat Mount
AUSTRALIA, NEW ZEALAND,
NORTH AMERICA EUROPE OCEANIA (DISTRIBUTOR)
3130 East Miraloma Avenue Swallow House, P.O. Box 295
Anaheim, CA 92806 USA Shilton Industrial Estate, Mordialloc Victoria 3195
USA and Canada – Shilton, Coventry, England CV79JY Australia
Phone: 800-368-9700 Phone: +44 (0) 2476 614700 Phone: 03 9586 6330
Fax: 800-
Resumen del contenido incluido en la página 2
Contents - Warnings 2 - Assembly drawing 3 - Flat panel list 4 - Parts list 6 - Checking the thread depth 9 - Finding the center of the flat panel display 10 - Positioning the mounting brackets 11 - Securing the mounting brackets 13 - Finding the wood studs behind the wall structure 14 - Marking the mounting points on the wall 15 - Securing the wall plate to wood studs 16 - Securing the wall plate to a concrete wall 17 - Securing the flat panel to the wall 18 - Lateral shift adj
Resumen del contenido incluido en la página 3
Assembly drawing Dimensions are in Inches and (mm) 28.000 (171.2) 16.000 1.245 (406.4) (31.75) A C L B 5.000 3.500 (127) (88.9) C 21.790 L (553.4) H C 16.000 (406.4) D 16.000 E (406.4) 16.000 G (406.4) F 24.290 (616.97) Description 1.943 A. Wall plate (49.3) B. Mounting brackets C. Griplate™ B D. Mounting hardware E. Safety screws H A F. Leveling feet 5.000 G. Wood stud (127) H. 5/16
Resumen del contenido incluido en la página 4
Flat panel list Acer Eizo Idex PDP7859: M6 x 20 5420T: M8 x 30 PDM4260: M4 x 16 Akai Electrograph Ikegami CTA42AR7A, PDP4247, PDP4290, PDP4294, DTS42W: M8 x 30 – ¼” nylon spacers (large) PDP5090, HPT500AN: M8 x 25 – ½” nylon spacers - PTM4202: M5 x 20 sleeves DTS4230: M8 x 30 – ½” nylon spacers - sleeves DTS42DD, DTS42GBDD, DTS42GB: M6 x 20 Akira Faroudja Integra EPM420, SV4201: M5 x 16 FPP42HD10, FPP50HD10: M4 X 16 PLA50V1: M4 X 16 Albatron
Resumen del contenido incluido en la página 5
Mitsubishi Princeton Graphics Tatung PD5010HD, PD5030: M4 x 16 AR3.4FTW,AR4.6PDP: M6 x 20 P46T: M6 x 20 Monivision Rainbow Toshiba PWV46AC, PD46W00: M6 x 20 Spectrum 3750: M6 x 20 42HP82: M4 X 16 PD42W, PD42W1: M8 X 30 – ½ ” nylon spacers (large) - sleeves RCA 50HP81: M8 X 30 – ½” nylon spacers (large) - sleeves NEC 50HP82: M4 X 16 PR42300, PHD42600, PHD50300, PHD50400: M4 X 16 4200W, 4210W, M4A,MP2, PX42M3A, 42PD1W, PD2 PHD50500: M8 X 20 Tredex M5A,M5G, 42MP1
Resumen del contenido incluido en la página 6
Parts list This wall mount is shipped with all proper installation hardware and components. Make sure that none of these parts are missing before beginning installation. If there are parts missing stop the installation and contact Premier Mounts. (Qty 8) M4 x 16 (Qty 6) M6 x 20 (Qty 4) M4 x 25 M8 x 20 (Qty 6) (Qty 8) M5 x 12 (Qty 6) M8 x 25 (Qty 6) M5 x 16 (Qty 6) M5 x 20 M8 x 30 (Qty 6) (Qty 4) M5 x 25 M8 x 35 (Qty 4) M5 x
Resumen del contenido incluido en la página 7
Parts list (con’t) Nylon spacers and flat washers The nylon spacers may be staked to achieve proper spacing. 9/16" Nylon spacers 1/4" Nylon spacers (large) (Qty 6) (Qty 6) 1/2" Nylon spacers Nylon sleeves (large) (Qty 4) (Qty 12) 5/16" Flat washers (metal) (Qty 6) 1" Nylon spacers (Qty 6) 1/4" Nylon spacers (small) (Qty 6) - 7 -
Resumen del contenido incluido en la página 8
Parts list (con’t) All of these parts are used to install the mounting bracket. Make sure that none of these parts are missing before beginning installation. If there are parts missing stop the installation and contact Premier Mounts. Level (1) Griplates™ (8) 5/16" flat washers (4) Wall plate (1) 5/16" x 3" Lag bolts (4) (used on wood studs Mounting brackets only) (left & right) Thread depth indicator (1)
Resumen del contenido incluido en la página 9
Checking the thread depth on your flat panel 1. Insert the thread depth indicator (supplied) through the thread inserts Figure 1 found on the back of the flat panel to make sure the inserts measure the same full depth and mark it. (see figure 1) 2. Locate the correct diameter screw for the thread insert. Compare your marking to the screws (supplied). If your selected screw is longer than the marking on the thread depth indicator DO
Resumen del contenido incluido en la página 10
Finding center of the flat panel display Proper installation procedure by qualified personnel as outlined in the installation instructions must be adhered to. Failure to do so could result in serious personal injury and possible damage to the flat panel. INVERT THE FLAT PANEL PLACE IT ON A SOFT, FLAT SURFACE TO PREVENT DAMAGE TO THE FLAT PANEL. USE A BLANKET, FOAM, ETC. FAILURE TO DO SO WILL RESULT IN DAMAGING THE FLAT PANEL. DO NOT LAY THE FLAT PANEL ON THE FLOOR WITHOUT ANY PROTECTION TO
Resumen del contenido incluido en la página 11
Positioning the mounting brackets Nylon spacers if Applicable (see chart) on page 4 and 5 Check the chart on page 4 and 5 to see if your flat panel needs nylon spacers. The nylon spacers provided, must be used. Failure to do so will result in damaging the flat panel. Install the nylon spacers to the mounting points on the flat panel see figure 3. See chart (if the nylon spacers apply to your flat panel). Inverted flat panel Center mark Lay the left and right mounting brackets (st
Resumen del contenido incluido en la página 12
Match the center of viewing guide with the center line you marked in step 1. See figure 5. C L Bottom of flat Align the panel mounting brackets Mounting bracket The mounting brackets are designed with a center of viewing guide on the side of them. See figure 6. Bottom of flat panel Center of flat panel Center of viewing guide - 12 -
Resumen del contenido incluido en la página 13
Securing the mounting brackets DIMPLES The Griplates™ have M4, M5 M6 and M8 hole patterns to fit the hardware that your flat panel requires. EXAMPLE: If your plasma uses M8 x 20 Phillip M8 screws. Use the M8 mounting points. See figure 7 M6 Once the mounting brackets are aligned secure the Griplate™ to the flat panel. M5 The dimples of the top plates have to be facing up and the bottom dimples must be facing down. Use (1) Griplate™ per M4 mounting point. See figure 8. Phillips sc
Resumen del contenido incluido en la página 14
Finding the wood studs behind the wall structure Using a (commercially available) wood stud finder, locate Wood stud finder the 16" or 24" stud centers behind the wall. Once found, (commercially available) make a pencil marking on the center of the wood studs. See figure 9. Mark the wall and the center of the wood studs. The wall plates have (3) 16" and (1) 24" mounting slot positions. (Look at the assembly drawing on page 3) 16" Wood studs behind the wall structure 16" Measure
Resumen del contenido incluido en la página 15
Marking the mounting points on the wall Place the bottom portion of the wall plate to the reference line and mark the four (4) lag bolt mounting points through the wall plate slots on the wall. Level the wall plate with the reference arrow pointing up to the ceiling. See figure 11. 16" W Wa alll l p pll aa te te Mounting slots Level Drill gun Pilot holes W Wo oo od d ssttuu dd ss Wood studs: Drill four (4) ¼" pilot holes to the marked wall. Concrete wall: Drill four (4) 3/8” pilot
Resumen del contenido incluido en la página 16
Securing the wall plate to wood studs Level and secure the plate to the wall with the Use a minimum diameter of 5/16” x 3” long wood reference arrow facing up to the ceiling. Secure screws. the plate using the four (4) 5/16" lag bolts and flat washers (supplied). See figure 13. Do not over tighten the lag bolts. Level (4) 5/16" x 3" lag bolts and (4) flat washers (supplied) Wall plate - 16 -
Resumen del contenido incluido en la página 17
Securing the wall plate to a concrete wall Level and secure the plate to the wall with the Use a minimum diameter of 5/16” x 2 ¼” long reference arrow facing up to the ceiling. Use a min wedge anchors (commercially available). dia of 5/16” x 2 ¼” lg concrete wedge anchors (commercially available). See figure 14. Do not over tighten the wedge anchors bolts. (4) 5/16" x 2 ¼” wedge anchors (commercially available) Wall plate - 17 -
Resumen del contenido incluido en la página 18
Securing the flat panel to the wall mount AT LEAST (2) QUALIFIED PERSONNEL ARE STRONGLY RECOMMENDED FOR INSTALLATION OF THIS PRODUCT. FAILURE TO DO SO COULD RESULT IN SERIOUS INJURY AND POSSIBLE DAMAGE TO THE FLAT PANEL. Raise the flat panel with the LEFT and RIGHT mounting brackets secured to the flat panel and insert the top hooks from each bracket to the rod from the wall plates. See figure 15. Wall plate TOP BOTTOM - 18 -
Resumen del contenido incluido en la página 19
Lateral shift adjustment Make any lateral shift adjustment and lock it by tightening the two (2) ¼”-20 Phillips screws found on the bottom of the mounting brackets. Use the foot leveler to adjust your plasma. See figure 16 Do not over tighten the ¼”-20 screws to the rods. Lateral shift To remove the display from the wall simply back off the ¼”-20 screws using a Phillips screwdriver and lift the
Resumen del contenido incluido en la página 20
Warranty PREMIER MOUNTS LIMITED LIFETIME WARRANTY What and Who is Covered by this Limited Warranty and for How Long Premier Mounts warrants this product to be free from defects in material and workmanship for the lifetime of the original installation of this product. The limited warranty is valid only for the original purchaser of the product. What Premier Mounts Will Do At the sole option of Premier Mounts, Premier Mounts will repair or replace any product or product part that i