Resumen del contenido incluido en la página 1
PWM-T210
Installation Instructions
UNIVERSAL FLAT PANEL MOUNT
IN-PWMT210.R0
Resumen del contenido incluido en la página 2
PWM-T210 TABLE OF CONTENTS Warning Statements 3 Parts List 4 Installation Tools 4 Locating the Center of the Display 5 Mounting Bracket Positioning 5 Securing the Mounting Brackets 6 Marking the Wall 7 Marking the Bottom Mounting Points 7 Securing the Lower Wall Plate 8 Securing the Upper Wall Plate 8 Mounting the Display 9 Securing the Display 10 Technical Specifications 11 Warranty 11 Contact Premier Mounts 11 Page 2 Installation Instructions
Resumen del contenido incluido en la página 3
PWM-T210 Safety Precautions This wall mount should be installed by qualified personnel having sufficient skill and competence to install it. Qualified installation specialists or your dealer should install the mount and set up the plasma display in order to avoid personal injury or property damage. Premier does not assume liability for injury or damage, including liability, caused by improper installation, mounting or setup of the plasma display, misuse, modification or natural disasters. The e
Resumen del contenido incluido en la página 4
PWM-T210 Parts List NOTE: This mount is shipped with all installation hardware and components. Make sure that none of these parts are missing and/ or damaged before beginning installation. If there are parts missing and/or damaged, please stop and contact Premier Mounts (800) 368-9700. 5/16" x 3" Lag Bolts Wall Plates (Qty 2) (Qty 8) 5/16" Flat Washers Mounting Brackets (Qty 8) (Qty 2) M6 x 30 Lateral Shift Locking Screws (Qty 2) Griplates™ (Qty 6) Template (Qty 1) M6 x 12 Safety Knobs (
Resumen del contenido incluido en la página 5
PWM-T210 Locating the Center of the Display CAUTION: Proper installation procedure by qualified personnel as outlined in the installation instructions must be adhered to. Failure to do so could result in serious personal injury and possible damage to the flat panel. WARNING: INVERT THE FLAT PANEL PLACE IT ON A SOFT, FLAT SURFACE TO PREVENT DAMAGE TO THE FLAT PANEL. USE A BLANKET, FOAM, ETC. FAILURE TO DO SO WILL RESULT IN DAMAGING THE FLAT PANEL. DO NOT LAY THE FLAT PANEL ON THE FLOOR WITHOUT
Resumen del contenido incluido en la página 6
PWM-T210 Display Bottom C L Align the Mounting Bracket Mounting Viewing Brackets Guide Center of Display Center Display Bottom Figure 4 Figure 5 4. Match the center of viewing guide 5. The mounting brackets are designed with the center line you marked in with a center of viewing guide on the step 1 (Figure 4). side of them (Figure 5). Securing the Mounting Brackets The Griplates™ have M4, M5, M6 and M8 hole patterns to fit the hardware that your flat panel requires. NOTE: Your plasma uses M8
Resumen del contenido incluido en la página 7
PWM-T210 Marking the Wall Viewing Port Center Mark the Wall VIEWING PORTS CENTER OF VIEWING LINE Wall Structure MARKING THE LINE Figure 8 Figure 7 1. Align the center viewing port from the 2. Mark a line on the bottom of the carton template to the wall. Match the carton template (Figure 8). center of viewing port to the center of viewing height desired (Figure 7). Marking the Bottom Mounting Points CAUTION: The lag bolts must be secured to the center of a stud. Use a commercially a
Resumen del contenido incluido en la página 8
PWM-T210 Securing the Lower Wall Plate Marked Wall Level Wall Plate Wall Plate Template Figure 11 Figure 12 1. Level and secure the plate to the wall 3. When the bottom wall plate is properly installed to the wall. with the reference arrow facing up to the 4. Lay the carton template on top of the wall ceiling (Figure 11). plate. 2. Secure the plate using the provided lag 5. Lay the top wall plate on top of the bolts and washers. cardboardtemplate and mark the four (4) mounting points (Fig
Resumen del contenido incluido en la página 9
PWM-T210 Mounting the Display WARNING: AT LEAST (2) QUALIFIED PERSONNEL ARE STRONGLY RECOMMENDED FOR INSTALLATION OF THIS PRODUCT. FAILURE TO DO SO COULD RESULT IN SERIOUS INJURY AND POSSIBLE DAMAGE TO THE FLAT PANEL. Top Bottom Figure 15 1. Raise the flat panel with the mounting brackets secured to the flat panel and insert the top and bottom hooks from each bracket to the rods from the wall plates (Figure 15). Lateral Shift M6 x 30 Lateral Shift Screw M6 x 30 Lateral Shift Screw Figure 16 2.
Resumen del contenido incluido en la página 10
PWM-T210 Securing the Display M6 x 12mm M6 x 12mm Safety Knob Safety Knob Figure 17 1. Tilt the flat panel and secure the two (2) M6 x 12 mm safety knobs to each of the mounting brackets (Figure 17). NOTE: To remove the display from the wall simply extend the display to its maximum tilt range, remove the two (2) M6 x 12mm Safety Knobs, push the flat panel back to it's flat position and loosen or remove the two (2) M6 x 30 lateral shift screws and lift the unit of the wall. Page 10 Installation
Resumen del contenido incluido en la página 11
PWM-T210 Technical Specifications Dimensions shown in (mm)/inches. Warranty Limited Lifetime Warranty All Premier Mounts products carry a limited lifetime warranty from ship date against defects in materials and workmanship. Premier Mounts is not liable for improper installation that results in damage to mounts, adapters, display equipment or personal injury. Contact Premier Mounts In the event of missing and/or damaged equipment, or technical questions, the following information can help in the