Resumen del contenido incluido en la página 1
I6 Infortrend 5251F6
15-bay Rackmount & Tower Enclosures
Installation Guide
October 22, 2003 • Revision A
Patent Pending
Resumen del contenido incluido en la página 2
Copyright Copyright 2003 by JMR Electronics, Inc. All Rights Reserved. No part of this publication may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language, in any form or by any means, electronic, mechanical, photocopying, recording or otherwise, without the express written permission of JMR Electronics, Inc. Sales and Ordering Information JMR Electronics, Inc. 20400 Plummer Street Chatsworth, CA 91311 USA Phone: 818-993-4801 Fax: 818-993-9
Resumen del contenido incluido en la página 3
Table of Contents 1. Introduction 2/4/6/8/10/12/15-bay Product Family Features . . . . . . . . . . . . . . . . . . . . .1-1 Rackmount Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-2 Tower Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-2 Fibre Channel Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-3 Loop Expansion . . . . . . . . . . . . . . . .
Resumen del contenido incluido en la página 4
Host CH-0 and CH-1 (Top) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-4 CH 2 (Bottom) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-4 CH 3 (Top) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-5 CH 4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-5 CH 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Resumen del contenido incluido en la página 5
The 15-bay FORTRA I6 Infortrend 5251F6 enclosures are designed to be used with a host system to provide a high-end RAID subsystem. The following is a summary of the 15-bay Rackmount and Tower enclosure features: • The 15-bay FORTRA I6 Infortrend 5251F6 Tower enclosure supports up to fifteen LP SCA 40-pin SCA drives. This model supports up to six 2Gb/s Fibre Channel loops. The Fibre Channel enclosure has dual or quad fibre channel host ports and dual or quad fibre channel
Resumen del contenido incluido en la página 6
FORTRA products use advanced mid-plane technology developed by JMR, which allows power supplies, drives, and all other enclosure components to interface into a single board. This provides superior performance and easy connectivity. The host interface supports SFP Fibre Channel connections at 2Gb/s. All 15-bay FORTRA 2Gb/s Fibre enclosures have built-in SES on the personality card that allows control and monitoring of some enclosure components. Rackmount Specifications Dimensions/Weigh
Resumen del contenido incluido en la página 7
Blower Quantity: 4 (2 per cannister) Size: 97mm (3.82") each Air Flow: 25.42CFM (0.72m3/min) each Noise: 52dB(A) Fibre Channel Features Loop Expansion FORTRA 15-bay 2Gb/s Fibre Channel JBOD enclosures include a loop expansion I/O connector on each fibre channel drive port. This allows the connection to other Fibre Channel JBOD enclosures. Loop Bypass and Clock Timing Circuit Each port includes a loop bypass circuit that monitors each slot for a loop connection. It has two modes of opera
Resumen del contenido incluido en la página 8
This chapter covers specification information for all FORTRA enclosures. The following matrix describes the available configurations for FORTRA and enclosures. FR XX X L 2 1 X 2 X XX X X SINGLE/DUAL CONTROLLER S = Single Controller D = Dual Controller BACKPLANE TYPE - = 1 Gigabit Backplane 2 = 2 Gigabit Backplane CONTROLLER MANUFACTURER/MODEL#/INTERFACE - = None (Blank if at the end of P/N) H1 = Chaparral G5312/ LVD Host/ LVD Dr
Resumen del contenido incluido en la página 9
Environmental Specifications Operating Temperature: 5°C to 40°C (41°F to 104°F) Storage Temperature: 0°C to 65°C (32°F to 149°F) The maximum recommended ambient temperature depends on the recommendation of the manufacturer for the devices being installed. Electrical Specifications AC Inlet Type: IEC320/EN60320 Power Cord: NEMA5-15P Power Supply: Auto-switching for 110/220V operation Agency Compliance FORTRA enclosures have been designed and built to comply with the FCC, UL, CSA/TUV, CE, and
Resumen del contenido incluido en la página 10
Thermal Specifications FORTRA enclosures have been designed to meet the air-flow/cooling requirements for popular 7,200, 10,000 and 15,000 RPM disk drives. Using high performance blowers, air is pulled in from all open vents and exhausted out the back of the unit. Rotation Vibration Specifications FORTRA enclosures have been designed to meet the rotation vibration/shock requirements for popular 7,200, 10,000, and 15,000 RPM disk drives. Fault Indication Features This section reviews th
Resumen del contenido incluido en la página 11
This chapter covers Fibre Channel device installation for 15-bay rackmount and15-bay tower enclosures. SCA Connection and Hot-Swapping The unit uses SCA-2, 40-pin connectors which provide a safe means of connection/disconnection when hot-swapping devices. In order to hot-swap devices, the host adapter or RAID controller and host operating software must support the feature. Any SCA drive is capable of plugging directly into the backplane of the unit and should not requir
Resumen del contenido incluido en la página 12
Drive Installation Device Mounting Holes (4) Status Indicators Handle Device mounting screws are included with the unit for device mounting. The JMR part number for the #6-32" mounting screws is HDS-01906. WARNING: Before device installation, alleviate any electro-static discharge by touching a grounded metal assembly. Static can be potentially damaging to enclosure components. WARNUNG: Berühren Sie vor der Festplatteninstallation geerdete Metallgegenstände, um elektro statische Aufladung abzu
Resumen del contenido incluido en la página 13
4. Repeat steps 1 through 3 until all devices are installed, then move onto step 5 to complete unit setup and installation. 5. Configure ID and other options as required. See Chapter 4 for device setup. 6. For 15-bay rackmount units, refer to Chapter 7 to install the enclosure into a cabinet. 7. Establish host connection. See Chapter 4 for host connection. 3-3 FORTRA 15-bay I6 Infortrend 5251F6 Installation Guide Rev A
Resumen del contenido incluido en la página 14
Slot 0, ID 0 Slot 1, ID 1 Slot 2, ID 2 Slot 3, ID 3 Slot 4, ID 4 Slot 5, ID 5 Slot 6, ID 6 Slot 7, ID 7 Slot 8, ID 8 Slot 9, ID 9 Slot 10, ID 10 Slot 11, ID 11 Slot 12, ID 12 Slot 13, ID 13 Slot 14, ID 14 This chapter covers Fibre Channel device configuration and option settings. All Fibre Channel 15-bay units have built-in SES on the personality card. Refer to Chapter 8 for SES operation. Please take note of the installation warnings below before beginning setup. WARNI
Resumen del contenido incluido en la página 15
Setting ID Rotary switch settings only affect Slot 0 and all other slots are sequentially increased by a value of one after that slot. The ID is set sequentially starting from a base address. The base address, or starting address, is set via a 0-7 position rotary switch located on the personality module. There is a second 0-15 position rotary switch which can be changed to modify the base address setting. The default value for both switches is 0. In this default configuration, the device ID
Resumen del contenido incluido en la página 16
ID Conflict When two devices share the same ID, a conflict occurs. This should not happen unless two or more enclosures are daisy chained together. If devices in one enclosure conflict with devices in another enclosure, the devices will re-arbitrate ID and resolve the conflict. Option Settings Three option settings are located on the personality card. To access the jumpers, the cover must be removed. The figure below shows the location of the option settings on the personality card. W1* Del
Resumen del contenido incluido en la página 17
External I/O Connection The external I/O connections are located on both the personality card and the contoller card. There are five SFP I/O connectors accessible from the rear of the unit as shown in the figure below. RS232 for Ethernet for Host/Drive Drive Host/Drive Host Host Controller 0 Controller 0 CH 5 CH 3 CH 4 CH 1 CH 0 Host/Drive Drive Ethernet for RS232 for Host Host Host/Drive CH 5 Controller 1 CH 2 Controller 1 CH 0 CH 1 CH 4 Host CH-0 and CH-1 (Bottom) Input connections for Host
Resumen del contenido incluido en la página 18
CH 3 (Top) This is a standard (2Gb/s) SFP transceiver connector used to connect to a drive expansion enclosure for Loop B side of drives. The 15 internal drives loop side B are connected to this loop as well. CH 4 This is a standard (2Gb/s) SFP transceiver connector used to connect to a host system or drive expansion bay. Host or disk connection is firmware selectable. CH 5 This is a standard (2Gb/s) SFP transceiver connector used to connect to a host system or drive expansion bay. Host or di
Resumen del contenido incluido en la página 19
!" This chapter covers all operations of the blowers for 15-bay units. Refer to Chapter 1 for blower specifications. The blower is hot swappable and can be removed or installed while the enclosure continues to function, however, failure to replace a non-working blower within a reasonable period of time may expose drives to extreme heat, which could cause loss of data. WARNING: Blowers are a system critical component. Non-operating blowers should be replaced as soon as possi
Resumen del contenido incluido en la página 20
WARNING: Avoid direct contact with the blower intake access hole while the blower is running. The blower operates at high speeds and can cause injury. User’s removing or installing a blower must be awarre of the blower access hole. Contact with the access hole must be avoided while the blower is running to prevent injury. Blower Replacement If the blower has stopped running or the fault LED indicator is lit, the blower may need to be replaced. Before replacing, the cable connection should be che