Resumen del contenido incluido en la página 1 
                    
                        ®
Portfolio 
 
Installation Instructions for MD6xT6, MD6xT4, MD6CPxT6 and MD6CPxT4 
Commercial Recessed Housings 
 
 
 
 
 
 
Risk Of Fire. 
Risk Of Electrical Shock Risk Of Fire 
  
  
 Do not install insulation 
Disconnect power at fuse or Supply conductors (power 
within 3 inches (76 mm) of 
circuit breaker before wires) connecting the fixture 
 
any part of the fixture or in a 
installing or servicing. must be rated minimum 
 
way that may entrap heat. 
90°C. If uncertain, consult an 
 
elec
                    
                    Resumen del contenido incluido en la página 2 
                    
                        ® Portfolio      Step 1. Install fixture into ceiling cavity using ½” electrical conduit, ¾” channel, 1½” channel or   “ x ½” bar stock as  mounting rails (furnished by others) by inserting them into hanger brackets at both ends of the fixture as shown.    Step 2. Secure mounting rails to support structures.    Step 3. Adjust fixture so bottom of plaster ring is flush with finished ceiling line, using screws securing hanger brackets.   Hanger bracket is reversible for a total adjustment of 5”.  
                    
                    Resumen del contenido incluido en la página 3 
                    
                        ® Portfolio    Distribution Selection & Trim Installation          Step 1. Install the proper lamp type and wattage into the socket.  Make sure the new lamp does not have any  fingerprints, dust, lint, etc.    NOTE: The lamp-socket assembly is installed onto the trim in one of three possible positions.  These are labeled  Narrow, Medium and Wide.  The selected position determines the light distribution from the fixture.      Step 2. As shown in figure at right, the trim assembly includes  six pl
                    
                    Resumen del contenido incluido en la página 4 
                    
                        ® Portfolio    Lamping Information    • The electronic ballast has a very important shutdown timing feature that turns off the ballast output after time  periods ranging from 2 minutes up to 30 minutes if a lamp does not start or operate properly or if the fixture wiring  is improper.  For proper system diagnosis and at lamp replacement time, the  INPUT POWER TO THE BALLAST  MUST BE RESET (turn power off, wait 10 seconds, turn power back on) to start a new lamp.  • Take proper care in handling a
                    
                    Resumen del contenido incluido en la página 5 
                    
                        ® Portfolio    To re-lamp from below the ceiling:    Step 1. Remove the lower trim by gently pulling the trim  down until the torsion spring stops are reached.   Remove the trim from the torsion spring receivers.    Step 2. Remove the socket assembly from the top of the  trim using the two thumbscrews.  Use gloves if the  assembly is still warm.  Gently remove the old  lamp.  Dispose the old lamp according to local  recycling code.    Step 3. Install the new lamp.  Make sure the new lamp  does n
                    
                    Resumen del contenido incluido en la página 6 
                    
                        ® Portfolio    Ballast Replacement    • The ballast should be replaced by a qualified electrician.  • The ballast may be replaced either from below or above the ceiling.    Step 1. Remove the trim assembly.    Step 2. Inside the housing, remove the access door to provide access to the ballast and junction box.    Step 3. Remove the existing ballast and replace with the new ballast.  Refer to the applicable wiring diagram at the end  of this document.    Step 4. Close the access door.  Re-install
                    
                    Resumen del contenido incluido en la página 7 
                    
                        ® Portfolio    Step 3. Remove the socket from the bracket by removing the two Philips screws which secure it in place.  Step 4. Install the new socket using the original screws.  Step 5. Install the lamp.  Make sure the lamp does not have any fingerprints, dust or lint.  Step 6. Re-assemble the socket assembly back onto the trim.  Be sure to re-assemble the lamp assembly in the  same distribution as before (Narrow, Medium or Wide).  Secure with the two thumbscrews.  Step 7. Install the trim back
                    
                    Resumen del contenido incluido en la página 8 
                    
                        ® Portfolio    2. For Housings with Ballasts requiring dedicated voltage input, and a Quartz Restrike System.  Includes Catalog  Numbers MD6xxx1EQ and MD6xxx2EQ.            3. For Housings with Ballasts requiring dedicated voltage input, and an Emergency Circuit Quartz Lamp.  Includes  Catalog Numbers MD6xxx1EX and MD6xxx2EX.        704530 Rev. A  - 8 -              Customer First Center · 1121 Highway 74 South · Peachtree City, GA 30269                                                           
                    
                    Resumen del contenido incluido en la página 9 
                    
                        ® Portfolio    4. For Housings with Universal voltage input, 120-277V, with Advance Ballast (70W).  Includes Catalog Numbers  MD6xxxG12E, MD6xxxG85E and MD6xxxG65E.            5. For Housings with Universal voltage input, 120-277V, with Advance Ballast (70W) and a Quartz Restrike System.   Includes Catalog Numbers MD6xxxG12EQ, MD6xxxG85EQ and MD6xxxG65EQ.          704530 Rev. A  - 9 -              Customer First Center · 1121 Highway 74 South · Peachtree City, GA 30269                           
                    
                    Resumen del contenido incluido en la página 10 
                    
                        ® Portfolio    6. For Housings with Universal voltage input, 120-277V, with Advance Ballast (70W) and an Emergency Circuit Quartz  Lamp.  Includes Catalog Numbers MD6xxxG12EX, MD6xxxG85EX and MD6xxxG65EX.      7. For Housings with Universal voltage input, 120-277V, with Vossloh Schwabe Ballast (20W or 39W).  Includes Catalog  Numbers MD6xxxG12E, MD6xxxG85E and MD6xxxG65E.    704530 Rev. A  - 10 -              Customer First Center · 1121 Highway 74 South · Peachtree City, GA 30269               
                    
                    Resumen del contenido incluido en la página 11 
                    
                        ® Portfolio    8. For Housings with Universal voltage input, 120-277V, with Vossloh Schwabe Ballast (20W or 39W) and a Quartz  Restrike System.  Includes Catalog Numbers MD6xxxG12EQ, MD6xxxG85EQ and MD6xxxG65EQ.        9. For Housings with Universal voltage input, 120-277V, with Vossloh Schwabe Ballast (20W or 39W) and an Emergency  Circuit Quartz Lamp.  Includes Catalog Numbers MD6xxxG12EX, MD6xxxG85EX and MD6xxxG65EX.      704530 Rev. A  - 11 -              Customer First Center · 1121 Highway