Resumen del contenido incluido en la página 1
ICP-CC404
Installation Guide
ICP-CC404
EN Control Panel
Resumen del contenido incluido en la página 2
ICP-CC404 | Installation Guide | Copyright Notice Copyright Notice Notice of Liability Unless otherwise indicated, this publication is the This material is designed for use by tradespeople with copyright of Bosch Security Systems, Inc. (“Bosch”). expertise in the installation of this product. Persons All rights are reserved. without appropriate expertise should seek assistance before attempting installation. You may download a single copy of this publication. By downloading the publicat
Resumen del contenido incluido en la página 3
ICP-CC404 | Installation Guide | Contents 5.0 Remote Radio Transmitter Operations....24 Contents 5.1 Indications from Remote Radio Transmitter 1.0 Introduction ......................................................7 Operations ........................................................24 1.1 Features ...............................................................7 5.2 Remote Radio User Code Priority Levels.....24 1.2 Quick Start..........................................................7
Resumen del contenido incluido en la página 4
ICP-CC404 | Installation Guide | Contents 6.3.5 Bell Test.............................................................37 13.2 User Codes .......................................................51 6.3.6 Strobe Test ........................................................37 13.3 User Code Priority...........................................52 6.3.7 Turning Day Alarm On and Off ....................38 14.0 Zone Information...........................................53 6.3.8 Fault Analysis Mode .
Resumen del contenido incluido en la página 5
ICP-CC404 | Installation Guide | Contents 16.6 One-Shot Polarities ..........................................70 Figures 17.0 System Event Timers.....................................70 Figure 1: ICP-CP508W Eight Zone LED Codepad16 17.1 Programming Entry/Exit Timers....................70 Figure 2: ICP-CP508LW Eight Zone LCD 17.2 Entry Timer 1 ...................................................70 Codepad.....................................................17 17.3 Entry Timer 2 .........
Resumen del contenido incluido en la página 6
ICP-CC404 | Installation Guide | Contents Table 39: Telco Arm or Disarm Dialing Digits ......48 Tables Table 40: Default User Codes...................................51 Table 1: Zone Defaults...............................................8 Table 41: Priority Levels ...........................................52 Table 2: Zone Types ..................................................8 Table 42: EOL Resistor Options..............................53 Table 3: Codepad Indicators................
Resumen del contenido incluido en la página 7
ICP-CC404 | Installation Guide | 1.0 Introduction • Sensor watch 1.0 Introduction • Day Alarm Congratulations on selecting the ICP-CC404 Control • Walk Test Mode Panel for your installation. Take the time to read • Delayed reporting through this guide and familiarize yourself with the • 40 events in non-volatile memory outstanding operating and installation features of this system so you can get the most from your unit. 1.2 Quick Start In all aspects of planning, engineering,
Resumen del contenido incluido en la página 8
ICP-CC404 | Installation Guide | 1.0 Introduction When programming the telephone numbers for 1.2.2 Zone Defaults Receiver 1 and Receiver 2, you must program a 0 The default zone settings for the control panel are as a 10. Programming a 0 in the telephone listed in Table 1. You can program Zones 1 to 4 to number indicates the end of the dialing sequence. any of the zone types. Refer to Table 2 for the zone Unless otherwise stated, program a 0 as a 0 in all types you can select. loca
Resumen del contenido incluido en la página 9
ICP-CC404 | Installation Guide | 2.0 Programming Table 3: Codepad Indicators 2.0 Programming The control panel programming options are stored in Data Zone Indicators a non-volatile EPROM. This memory holds all Value 1 2 3 4 5 6 7 8 MAINS configuration and user-specific data even after a total 0 power loss. 1 X Because the data retention time is up to ten years 2 X without power, no reprogramming is required after 3 X powering down the control
Resumen del contenido incluido en la página 10
ICP-CC404 | Installation Guide | 2.0 Programming 2.3 Programming Option Bits 2.2 Programming with the When programming some locations, there are up to Programming Key four options per location. You can select one, two, The CC891 Programming Key allows you to store or three, or all four options for each location, but you copy programming information from your control can program only one value for the location. panel. After storing information in the programming Calculate this value
Resumen del contenido incluido en la página 11
ICP-CC404 | Installation Guide | 2.0 Programming 2.4.1 Command 958 – Enable/Disable Zone 2.4.2 Command 959 – Test the Programming Status Mode Key This function enables and disables Zone Status This command initiates a test of the programming Display Mode when using the hand-held key. You can use the CC891 Programming Key only programmer. The hand-held programmer shows the with the ICP-CC404 Control Panel. zones on the seven-segment display from left to right. The programming key
Resumen del contenido incluido en la página 12
ICP-CC404 | Installation Guide | 2.0 Programming Two beeps sound after the control panel memory 2.4.3 Command 960 – Exit from the Installer's is successfully copied to the programming key. A Programming Mode long beep indicates that the programming key is This command exits from the Installer’s corrupt and must be erased to clear the corrupt Programming Mode. You can exit from the Installer’s data. Refer to Section 2.4.7 Command 964 – Erase Programming Mode from any location. the P
Resumen del contenido incluido en la página 13
ICP-CC404 | Installation Guide | 2.0 Programming 2.4.7 Command 964 – Erase the Programming As shown in Table 6 on page 14, the transmission Key format is automatically set for domestic dialing and the Subscriber ID Number set for one identification This command erases all data from the programming beep. All reports, except Zone Status reporting and key. You can only use the CC891 Programming Key System Status reporting, are allocated to Receiver 1 with the ICP-CC404 Control Panel. fo
Resumen del contenido incluido en la página 14
ICP-CC404 | Installation Guide | 2.0 Programming Table 6: Command 965 Defaults Location Description Default Value Setting 032 Handshake Tone for Receiver 1 1 (Handshake Tone) 033 Transmission Format 4 (Domestic) 034 to 039 Subscriber ID Number 0, 0, 0, 0, 0, 1 (1 Beep) 332 Zone Status Reporting Options 2 (Receiver 2 only) 333 and 334 Open/Close Reports 11, 12 (Open/Close Reports) 335 Open/Close Reporting Options 2 (Receiver 2 only) 356 to 358 System Status – Access Denied 6, 7,
Resumen del contenido incluido en la página 15
ICP-CC404 | Installation Guide | 2.0 Programming Two beeps sound. The STAY and AWAY 2.5 Disable Factory Defaults indicators flashes to indicate you entered Program the Disable Factory Defaults feature in Installer’s Programming Mode. Location 900. 2. Enter [9 6 5 #]. The default value is 0. Two beeps sound after the control panel is This feature disables the DEFAULT button on the successfully reset. control panel printed circuit board (PCB) to prevent 3. Enter [9 6 0 #]. an ope
Resumen del contenido incluido en la página 16
ICP-CC404 | Installation Guide | 3.0 Codepad Indicators • Section 6.2.5 on page 35 to use the Master Code 3.0 Codepad Indicators to set zones to automatically isolate in STAY 3.1 ICP-CP508W Eight Zone LED Mode 2. Codepad Table 9: STAY Indicator Figure 1: ICP-CP508W Eight Zone LED Codepad Indicator Definition On The system is armed in STAY Mode 1 or STAY Mode 2 Off The system is not armed in STAY Mode 1 or STAY Mode 2 Flashing Zone Isolating Mode or setting STAY Mode 2 zone
Resumen del contenido incluido en la página 17
ICP-CC404 | Installation Guide | 3.0 Codepad Indicators Zone Indicators Table 12: FAULT Indicator The zone indicators (1 to 8) show the 1 2 3 … status of the zones as listed in Table 8 on Indicator Definition page 16. On A system fault must be corrected AWAY Indicator Off The system is normal (no faults) The AWAY indicator lights when the Flashing A system fault must be acknowledged system is armed in AWAY Mode. The ON indicator also lights when the Audible Indicators sys
Resumen del contenido incluido en la página 18
ICP-CC404 | Installation Guide | 4.0 System Operations Zone Isolating Mode There are two different methods to arm the system in AWAY Mode. You can always use the first method. This indicator (the person) flashes once You can use the other method only if Option 2 is every 3 sec when you attempt to isolate enabled in Location 429 (refer to Section 18.6 zones or program zones to automatically Consumer Options 2 on page 75). isolate for STAY Mode 2. Flashing If you must isolate a zo
Resumen del contenido incluido en la página 19
ICP-CC404 | Installation Guide | 4.0 System Operations Two beeps sound and the AWAY indicator is The indicators for any zones programmed to extinguished. automatically isolate in STAY Mode 1 flash until Exit Time expires. At the end of Exit Time, the zone 4.3 Arming the System in STAY Mode 1 indicators turn off and the codepad sounds one short Use STAY Mode 1 when you need to arm the beep. perimeter and unused areas of the premises to detect If a zone is not sealed at the end of Ex
Resumen del contenido incluido en la página 20
ICP-CC404 | Installation Guide | 4.0 System Operations If the STAY indicator does not light and a long beep 4.5 Arming the System in STAY Mode 2 sounds when attempting to arm the system, forced Use STAY Mode 2 to arm the perimeter and unused arming is not permitted. If this is the case, you must areas of the premises to detect an intruder, while at seal all zones or manually isolate them before you can the same time being able to move freely within an arm the system. automatically i