Resumen del contenido incluido en la página 1
AMC2 4W
APC-AMC2-4W | APC-AMC2-4WCF | APC-AMC2-4WUS
en Installation manual
Resumen del contenido incluido en la página 2
Resumen del contenido incluido en la página 3
AMC2 4W | en 3 Remarks This hardware is part of a security system. Access shall be lim- ited to authorized persons only. Some states do not allow the exclusion or limitation of implied warranties, or limitation of liability for incidental or consequen- tial damages, so the above limitation or exclusion might not apply to you. Bosch Security Systems retains all rights not expressly granted. Nothing in this license constitutes a waiver of Bosch’s rights under the U.S. Copyright laws or any oth
Resumen del contenido incluido en la página 4
4 en | AMC2 4W Table of Contents 1 Please read carefully 7 1.1 Explanation of Used Symbols 7 1.2 Internet 7 2 Safety Instructions 8 2.1 Important Safety Notes 8 2.2 FCC & ICES Information 10 2.3 Safety Precautions 11 2.4 Unpacking 12 3 Introduction 13 3.1 Description of the AMC2 4W 13 3.2 Equipment Configuration 15 3.3 Performance Characteristics 18 3.4 System Overview 19 4 Technical Data 20 5 Installing 22 5.1 Mounting 22 5.2 Demounting 23 5.3 Opening the AMC2 4W Case 24 5.4 Cabling 25 5.4.1 Co
Resumen del contenido incluido en la página 5
AMC2 4W | en 5 5.9 RS-485 Extension Module Bus 39 5.10 Wiegand Interface for Card Readers 39 5.11 Connecting Relay Outputs 41 5.12 Connecting Analog Input Devices 44 5.13 Tamper Protection 46 6Operating 48 6.1 Status Display of the AMC2 4W 48 6.2 Configuring the Ethernet Interface 50 6.3 Resetting the AMC2 4W 50 6.3.1 Resetting the Software 50 6.3.2 Resetting the Network Configurations 51 7 Appendix 53 7.1 Connecting Diagrams 53 7.2 Legend 57 8Index 58 Bosch Security Systems Installation manual
Resumen del contenido incluido en la página 6
6 en | AMC2 4W F.01U.024.965 | V.4 | 2006.09 Installation manual Bosch Security Systems
Resumen del contenido incluido en la página 7
AMC2 4W Please read carefully | en 7 1 Please read carefully 1.1 Explanation of Used Symbols Throughout this document, helpful tips, important notes, cau- tions and warnings will be presented for the reader to keep in mind. These appear different from the rest of the text as fol- lows: CAUTION! or WARNING! These warn the operator that damage to the program or equip- ! ment might occur. NOTE! Important Notes – must be followed for successful operation i and programming. Tips and shortcuts migh
Resumen del contenido incluido en la página 8
8 en | Safety Instructions AMC2 4W 2 Safety Instructions 2.1 Important Safety Notes 1. Read, Follow, and Retain Instructions - All safety and operating instructions must be read and followed properly before putting the unit into operation. Retain instructions for future reference. 2. Consider all Warnings - Adhere to all warnings on the unit and in the operating instructions. 3. Accessories - Use only accessories recommended by the manufacturer or those sold with the product. Accessories n
Resumen del contenido incluido en la página 9
AMC2 4W Safety Instructions | en 9 • If the unit has been dropped or the cabinet damaged. • If the unit exhibits a distinct change in performance, this indicates that service is needed. 7. Replacement Parts - When replacement parts are required, the service technician shall use replacement parts that are specified by the manufacturer. Unauthorized substitutions may result in fire, electrical shock or other hazards. 8. Safety Check - Upon completion of service or repair work on the unit, as
Resumen del contenido incluido en la página 10
10 en | Safety Instructions AMC2 4W 2.2 FCC & ICES Information This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC rules. The limits are desig
Resumen del contenido incluido en la página 11
AMC2 4W Safety Instructions | en 11 2.3 Safety Precautions Read instructions! Before working with the AMC2 4W, read these instructions carefully. Make sure you have understood all information ! described in this document. Warning! Risk of electric shock! External power supplies must be installed and put into service by qualified personnel. Compliance with the relevant regula- ! tions must be ensured. Warning! Risk of damaging equipment! • Always switch off power of the AMC2 4W before mod- ify
Resumen del contenido incluido en la página 12
12 en | Safety Instructions AMC2 4W CAUTION! Disconnect both AC and battery power supply before working ! on the controller. Warning! Risk of damage! Protect the hardware from electrostatic discharge by observing ESD instructions before unpacking or touching connectors or ! electronics. CAUTION: Lithium Battery Danger of explosion if battery is replaced incorrectly. Replace only with the same type as recommended by the manufacturer. ! Dispose used batteries according to the battery manufac
Resumen del contenido incluido en la página 13
AMC2 4W Introduction | en 13 3 Introduction 3.1 Description of the AMC2 4W The AMC2 4W is equipped with four independent interfaces for Wiegand type readers. By that it is able to control two doors with a reader in each direction and up to four doors with a reader in one direction only. Fig. 3.1 The Access Modular Controller AMC2 4W All necessary information for access verification is stored in a battery buffered on-board memory and a Compact Flash (CF) memory card. This guarantees autono
Resumen del contenido incluido en la página 14
14 en | Introduction AMC2 4W Fig. 3.2 The AMC2 4W in a four door safety lock The AMC2 4W can communicate upstream to the host com- puter via eight RS-485 multi-dropped, RS-232 or 10/100 Mbit/s Ethernet. It has eight analog input devices and eight relay out- puts. With its analog input devices, the AMC2 4W verifies, for example, if a lock is closed or open. The relay outputs can be used to activate lock mechanisms if access is granted, or acti- vate an external alarm system if an intrusion or
Resumen del contenido incluido en la página 15
AMC2 4W Introduction | en 15 3.2 Equipment Configuration Fig. 3.3 Upper circuit board with display (top side) 1. Internal tamper contact 2. DIL switch for RS-485 address selection, protocol and RS- 232/RS-485 selection 3. Lithium battery for buffering of static RAM and real time clock (RTC). The battery shall be replaced by qualified per- sonnel every ten years or if indicated by an appropriate event. 4. Reset push button - available by using the srew driver 5. LC Display 6. Push button to sel
Resumen del contenido incluido en la página 16
16 en | Introduction AMC2 4W 11. Configurable RS-232 host interface (ribbon cable connec- tor) 12. Configurable 10/100 Mbit/s Ethernet interface Fig. 3.4 Overview - Interfaces 13. RS-485 extension module bus (Pluggable screw connector) 14. External tamper contact (Pluggable screw connector) 15. Power supply (Pluggable screw connector) 16. Wiegand interfaces for up to 4 card readers (Pluggable screw connector) 17. Connectors for eight analog inputs (Pluggable screw con- nector) 18. Connectors fo
Resumen del contenido incluido en la página 17
AMC2 4W Introduction | en 17 Fig. 3.5 Jumper at the bottom side 19. Jumper: Selector for either potential free relay output or powered by AMC2 4W internal power supply (wet/dry con- tacts). 20. Jumper: Potential equalization between different mass systems and protective earth (shield)for the extension interface. Bosch Security Systems Installation manual F.01U.024.965 | V.4 | 2006.09
Resumen del contenido incluido en la página 18
18 en | Introduction AMC2 4W 3.3 Performance Characteristics – Intelligent access manager for 1 ... 4 entrances (e.g. doors, man traps, barriers) – Host address selectable via DIL sliding switch – Four possible configurable host interfaces: • RS-485 2-wire • RS-485 4-wire • RS-232 • Ethernet – Four peripheral input devices via Wiegand interface – Eight relay outputs • potential-free or • with internal power supply – Eight analog inputs with internal power supply – Battery buffered SRAM and rea
Resumen del contenido incluido en la página 19
AMC2 4W Introduction | en 19 3.4 System Overview The Access Controller AMC2 4W is connected between the management host system and different peripheral devices. By default a management host system is connected via Ethernet. A management host connection via RS-485 or RS-232 is also pos- sible. Fig. 3.6 System overview The number of controllers in one system is limited to 200. Corresponding to the available interfaces one AMC can be con- nected to each COM-Port using RS-232 mode. In RS-485 mode
Resumen del contenido incluido en la página 20
20 en | Technical Data AMC2 4W 4 Technical Data Hardware – Integrated Microcontroller (32Bit, 30MHz) – SRAM (256MB) – Serial EEPROM –RTC – Pluggable Compact Flash from 64 MB up to 1024 MB – Battery for SRAM and real time clock (RTC) – Host address selectable via DIL sliding switch or software – Host interface • RS-485 2-wire or 4-wire Transfer rate: 38,4 kBit/s (No parity, 8 Bit, 1 Stopbit) • RS-232 Transfer rate: 38,4 kBit/s (No parity, 8 Bit, 1 Stopbit) • Ethernet 10/100 Mbit/s – Four