Resumen del contenido incluido en la página 1
NOTICE
The CM9760-KBD/CM9760-KBR that has been shipped to you is configured for use with a CM9700-CC1
running software version 8.03. DIP switch 7 on the KBD/KBR is set to the ON position.
If you need to use the KBD/KBR with a CC1 running software version 7.80, set DIP switch 7 to the OFF
position.
Pelco World Headquarters • 3500 Pelco Way, Clovis, CA 93612-5699 USA • www.pelco.com
USA & Canada: Tel: 800/289-9100 • Fax: 800/289-9150
International: Tel: 1-559/292-1981 • Fax: 1-559/348-1120
C1550M
Resumen del contenido incluido en la página 2
INSTALLATION/OPERATION CM9760-KBD/ CM9760-KBR ™ System 9700 Intelligent Keyboard C540M-C (10/05)
Resumen del contenido incluido en la página 3
Resumen del contenido incluido en la página 4
Contents Important Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7 Regulatory Notices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8 Before You Begin . . . . . . . . . . . . . . . . .
Resumen del contenido incluido en la página 5
Turning Zones On and Off . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .38 Erasing Zones . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .39 DVR and VCR Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Resumen del contenido incluido en la página 6
List of Illustrations 1 Package Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9 2 CM9760-KBD Top View. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11 3 CM9760-KBD Bottom View . . . . . . . . . . . . .
Resumen del contenido incluido en la página 7
58 Partial Zone Overlap . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .37 59 Embedded Zones. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .38 60 DVR Control Menu . . . . . . . . . . . . . . . . . . . . . . .
Resumen del contenido incluido en la página 8
Important Safety Instructions 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. Do not use this apparatus near water. 6. Clean only with dry cloth. 7. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions. 8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat. 9. Do not defeat the safety purpose of th
Resumen del contenido incluido en la página 9
Regulatory Notices This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. RADIO AND TELEVISION INTERFERENCE This equipment has been tested and found to comply with the limits of a Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to
Resumen del contenido incluido en la página 10
Before You Begin Make sure the following parts are present before you install and operate your CM9760-KBD keyboard. PARTS LIST Qty Description 1 CM9760-KBD keyboard 1 RJ-45 straight cable 1 RJ-45 reversed cable 1 Power supply (KBD-PS-1) with power cord* 1 Installation/Operation manual *Customers in the US, UK, Australia, and Europe will receive one of the four power cords shown in Figure 1. PACKAGE CONTENTS RJ-45 REVERSED CABLE RJ-45 STRAIGHT CABLE 1 EA. 1 EA. SHIPPING BOX MANUAL 1 E
Resumen del contenido incluido en la página 11
Description The CM9760-KBD is a full-function desktop keyboard that allows you to control matrix systems, such as the CM9760, CM9770, and CM9780. The CM9760-KBR rack-mount model is also available and has the same features as the CM9760-KBD. It fits into a 19-inch, EIA-standard rack (4 RUs). You can control GPI-activated devices, receivers, camera/monitoring switching, and multiplexer screen functions, and create single/dual patterns, zones, zone labels, presets, and preset reca
Resumen del contenido incluido en la página 12
TOP VIEW Figure 2. CM9760-KBD Top View LCD Display Multipurpose Function Keys Escape Key Control Keys (F1-F24) Keypad (0-9, camera key, monitor key) Function Control Keys Bwd key: backward step through available camera selections Fwd key: forward step through available camera selections Run key: run a paused macro Mac key: selection, creation, and execution of macros Rcl/Alt key: • Rcl: recall previous selections • Alt: cycle through i
Resumen del contenido incluido en la página 13
BOTTOM VIEW Figure 3. CM9760-KBD Bottom View COM 1 Port COM 2 Port COM 3 Port 2 1 C Bus (not used) Relay Port DIP Switches Reset Key (recessed) Volume Knob 12 C540M-C (10/05)
Resumen del contenido incluido en la página 14
Installation CONNECTIONS 1. Make sure all DIP switches are OFF. 2. Connect the RJ-45 straight cable from the COM 1 port on the keyboard to the “Keyboard” connector on the power supply. 3. Connect the RJ-45 reversed cable from the “System” connector on the power supply to a SERCOM port on the CC1. 4. Plug the power supply into a 120 VAC power source. 5. Turn the main power supply switch ON. RJ-45 STRAIGHT CABLE PORTS 5 -12 SERCOM BOARD (LOCATED IN CM9700-CC1) POWER SUPPLY COM 1 PIN 1 P
Resumen del contenido incluido en la página 15
ACTIVATING SETUP MODE To configure the keyboard, you must activate Setup Mode. 1. Set DIP switch 2 ON. The following appears on the LCD display. ENTER SETUP PIN Figure 5. Enter Setup Pin 2. Enter 1234. This is the default setup PIN. The Setup Mode Menu appears with the version number. SETUP MODEv8.24 JSTK LCD ADV Figure 6. Setup Mode Menu CHANGING THE SETUP PIN To change the default setup PIN: 1. Select . The Advance Setup 1 Menu appears on the LCD display. Advance Setup 1 >H
Resumen del contenido incluido en la página 16
5. Select , enter the PIN again, and then select . “OK” appears on the Confirm line. 6.Select . You can also change the Define PIN from the same menu. CHANGING THE DEFINE PIN A PIN is required to use the features that are accessible via the Define Menu. The Define PIN is used in the operation mode to access extended keyboard functions and for initial access to ARM/DISARM alarm functions. The default Define PIN is 1234. To change the default Define PIN: 1. Move the cursor to Define Pin. 2. S
Resumen del contenido incluido en la página 17
CALIBRATING THE JOYSTICK AUTOMATICALLY This is the factory default calibration mode for all CM9760-KBD keyboards. Follow these steps if you change the joystick calibration mode to manual and want to go back to automatic joystick calibration. 1. Select from the Setup Mode menu. 2. With the joystick in the center, select and then to activate automatic calibration mode. 3.Select . The joystick calibrates automatically every 30 minutes with no additional user action required. ADJUSTI
Resumen del contenido incluido en la página 18
DIRECT CAMERA CONTROL Cameras can be connected directly to COM 1 and/or COM 2 located on the bottom of the CM9760-KBD. Up to 16 cameras can be connected to each port for a total of 32. Follow these steps and refer to Figure 11. ® ® NOTE: Use cameras that have RS-422 Pelco P-type protocol. This includes most Legacy , Intercept , and System 9750/9760 ERD receivers. POWER SUPPLY PIN 1 TX + PIN 1 TX + COM 2 COM 1 PIN 2 TX - PIN 2 TX - PELCO CM9760-KBD RECEIVER RECEIVER RECEIVER R
Resumen del contenido incluido en la página 19
3. Select to choose the COM port you are going to configure. The figure below shows the COM 1 port. Advance Setup 1 Host Direct Cam Ctrl Even >COM 1 4800 COM 2 4800 Even Even COM 3 4800 SAVE Figure 14. COM 1 4. Select or to choose the baud rate and to choose the parity. In the figure below, a 9600 baud rate and Odd parity has been chosen for COM 1. Advance Setup 1 Host Direct Cam Ctrl COM 1 9600 Odd > Even COM 2 4800 COM 3 4800 Even SAVE Figure 15. Baud and Parity 5. Select
Resumen del contenido incluido en la página 20
10. Enter a logical number for the physical port. In the figure below, 10 has been entered. Camera Assign Physical Logical 1 2 3 4 5 6 7 8 > 0 10 T T T T M M M M 1 0 T T T T M M M M 2 0 T T T T M M M M 3 0 T T T T M M M M SAVE AUX Figure 18. Logical Number Entered 11. Select . The number is placed into the selected row for logical numbers. Camera Assign Physical Logical 1 2 3 4 5 6 7 8 > 0 10 T T T T M M M M 1 0 T T T T M M M M 2 0 T T T T M M M M 3 0